Distorções harmônicas: estudo de caso de uma planta industrial

Registro completo de metadados
MetadadosDescriçãoIdioma
???dc.contributor.advisor???: dc.contributor.advisorRocha, Joaquim Eloir-
Autor(es): dc.contributor.authorMori, Cassio Kenji-
Autor(es): dc.contributor.authorBadelli, Diego do Carmo-
Data de aceite: dc.date.accessioned2015-02-25T19:36:48Z-
Data de aceite: dc.date.accessioned2017-03-17T14:41:15Z-
Data de disponibilização: dc.date.available2015-02-25T19:36:48Z-
Data de disponibilização: dc.date.available2017-03-17T14:41:15Z-
Fonte completa do material: dc.identifierhttp://repositorio.roca.utfpr.edu.br/jspui/handle/1/3059-
???dc.identifier.citation???: dc.identifier.citationMORI, Cassio Kenji; BADELLI, Diego do Carmo. Distorções harmônicas: estudo de caso de uma planta industrial. 2014. 107 f. Trabalho de Conclusão de Curso (Graduação) – Universidade Tecnológica Federal do Paraná, Curitiba, 2014.pt_BR
Fonte: dc.identifier.urihttp://www.educapes.capes.gov.br/handlecapes/171298-
Resumo: dc.description.abstractThis paper discusses a case study in depth about an electrical phenomenon in facilities known as harmonics, covering the full range of study that involves their behavior, divided into topics that would be needed to further knowledge of practical methodology later. Firstly, the definition and perception of harmonics, causes and effects, the calculations related to the regulations and recommendations involved analyzers and energy that would be used for measurement were studied. Then the procedures for measuring harmonics were studied, and well organized with a roadmap of cargo selection and measuring points which would be necessary to achieve the proposed objective comparison of the two analyzers used and also the various regulations that were surveyed. The measurement procedures and data acquisition were detailed in the work and results discussed on the basis of analysis software analyzers. At the end of all organized, calculated and compared with the standards, measurements verified the condition of the facility in relation to the harmonics, and the need to recommend improvements and suggestions for controlling the movement thereof. At the end it was concluded that applying the knowledge gained with improvements to the plant comprising the effects of harmonics and applying filters or reactors, can be effective for energy quality facilities industries that have the same load profile, especially the chemical sector.pt_BR
Palavras-chave: dc.subjectHarmônicos (Ondas elétricas)pt_BR
Palavras-chave: dc.subjectEnergia elétrica - Análisept_BR
Palavras-chave: dc.subjectCircuitos elétricospt_BR
Palavras-chave: dc.subjectHarmonics (Electric waves)pt_BR
Palavras-chave: dc.subjectElectric power - Analysispt_BR
Palavras-chave: dc.subjectElectric circuitspt_BR
Título: dc.titleDistorções harmônicas: estudo de caso de uma planta industrialpt_BR
Tipo de arquivo: dc.typeoutropt_BR
Aparece nas coleções:Repositorio Institucional da UTFPR - RIUT

Não existem arquivos associados a este item.
Mostrar registro simples do item Visualizar estatísticas

Avaliação

1 2 3 4 5

Conteúdo acessível em Libras usando o VLibras Widget com opções dos Avatares Ícaro, Hosana ou Guga. Conteúdo acessível em Libras usando o VLibras Widget com opções dos Avatares Ícaro, Hosana ou Guga.