Validação do teste olfatório Olfato-UP em adultos na população brasileira

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorFornazieri, Marco Aurélio-
Autor(es): dc.contributorAlmeida, Silvio Henrique Maia de-
Autor(es): dc.contributorMiyake, Marcel Menon-
Autor(es): dc.creatorUeda, Denis Massatsugu-
Data de aceite: dc.date.accessioned2025-05-15T12:46:34Z-
Data de disponibilização: dc.date.available2025-05-15T12:46:34Z-
Data de envio: dc.date.issued2024-10-09-
Data de envio: dc.date.issued2024-10-09-
Data de envio: dc.date.issued2024-08-15-
Fonte completa do material: dc.identifierhttps://repositorio.uel.br/handle/123456789/17988-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/974537-
Descrição: dc.descriptionIntrodução: Os testes olfatórios validados no Brasil atualmente se deparam a barreiras financeiras, logísticas ou ambas. Consequentemente, a sua aplicação na prática clínica é pouco difundida. O Olfato-UP é um teste olfatório que propõe sanar estas barreiras, porém, ainda não está validado no Brasil. Objetivo: Validar o teste Olfato-UP na população brasileira adulta e idosa. Métodos: Estudo realizado em 3 fases. Na primeira fase realizada a avaliação do tempo de aplicação e da familiaridade da população com os odores utilizados, para isso, verificado o índice de acerto mínimo de 75% em todas as fragrâncias utilizada sem pacientes sem queixas olfatórias. A segunda fase teve como propósito definir o cut-off do Olfato-Up e avaliar sensibilidade, especificidade e acurácia do teste. Nesse momento da pesquisa aplicado os testes olfatórios Olfato-Up e University of Pennsylvania Smell Identification Test. Por fim, a terceira fase teve como foco avaliar a reprodutibilidade do teste e novamente o tempo para realização do Olfato-Up. Aplicado, após um intervalo mínimo de duas semanas, o teste em 32 pacientes que participaram da fase 1. Resultados: Os odorantes utilizados tiveram uma identificação bem-sucedida (>75%), exigida para participantes saudáveis. Com o cut-off de 7 o teste apresentou para identificação de anosmia sensibilidade de 88,2%, especificidade de 86,6%, acurácia de 86,7%, área sob a curva 90,7%. Para hiposmia severa com o mesmo valor de cuf-off a sensibilidade foi de 70,2%, especificidade 96%, acurácia de 89,8% e área sob a curva de 90,1% coeficiente de concordância intraclasse de 0,89, coeficiente de correlação de Pearson (r=0,811 p<0,001), média do teste de Bland Altman -0,18 IC 95% -1,68 a 1,32, e tempo médio de aplicação de 3,8 minutos. Conclusão: O teste Olfato-UP é um teste de rápida aplicação e alta reprodutibilidade, especificidade, sensibilidade e acurácia. Pode ser considerada uma opção de exame para a avaliação do olfato na prática clínica.-
Descrição: dc.descriptionIntroduction: Olfactory tests validated in Brazil currently face financial, logistical, or both barriers. Consequently, their application in clinical practice is limited. Olfato-UP is an olfactory test designed to overcome these barriers; however, it has not yet been validated in Brazil. Objective: To validate the Olfato-UP test in the Brazilian adult and elderly population. Methods: The study was conducted in 3 phases. In the first phase, the time required for administration and the familiarity of the population with the odors used were evaluated, aiming for a minimum accuracy index of 75% in all fragrances used among patients without olfactory complaints. The second phase aimed to define the Olfato-UP cutoff and evaluate the sensitivity, specificity, and accuracy of the test. In this phase, the Olfato-UP and University of Pennsylvania Smell Identification Test were administered. Finally, the third phase focused on assessing the reproducibility of the test and again measuring the time required for the Olfato-UP. The test was administered to 32 patients who participated in phase 1, with a minimum interval of two weeks between administrations. Results: The odorants used had a successful identification rate (>75%), as required for healthy participants. With a cutoff of 7, the test showed a sensitivity of 88.2%, specificity of 86.6%, accuracy of 86.7%, and area under the curve of 90.7% for anosmia identification. For severe hyposmia with the same cutoff value, sensitivity was 70.2%, specificity 96%, accuracy 89.8%, and area under the curve 90.1%. Intraclass correlation coefficient was 0.89, Pearson correlation coefficient (r=0.811, p<0.001), Bland-Altman test mean -0.18, 95% CI -1.68 to 1.32, and average application time was 3.8 minutes. Conclusion: The Olfato-UP test is quick to administer with high reproducibility, specificity, sensitivity, and accuracy. It can be considered as an option for olfactory evaluation in clinical practice.-
Formato: dc.formatapplication/pdf-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Relação: dc.relationCCS - Departamento de Clínica Médica-
Relação: dc.relationPrograma de Pós-Graduação em Ciências da Saúde-
Relação: dc.relationUniversidade Estadual de Londrina - UEL-
Palavras-chave: dc.subjectOlfato-
Palavras-chave: dc.subjectTestes de diagnóstico-
Palavras-chave: dc.subjectDistúrbios do olfato-
Palavras-chave: dc.subjectLimiar sensorial-
Palavras-chave: dc.subjectAnosmia-
Palavras-chave: dc.subjectHiposmia-
Palavras-chave: dc.subjectCiências da Saúde - Medicina-
Palavras-chave: dc.subjectCiências da Saúde - Medicina-
Palavras-chave: dc.subjectOlfaction-
Palavras-chave: dc.subjectDiagnostic tests-
Palavras-chave: dc.subjectOlfaction disorders-
Palavras-chave: dc.subjectSmell-
Palavras-chave: dc.subjectSensory threshold-
Palavras-chave: dc.subjectAnosmia-
Palavras-chave: dc.subjectHyposmia-
Título: dc.titleValidação do teste olfatório Olfato-UP em adultos na população brasileira-
Título: dc.titleValidation of the Olfactory-UP olfactory test in adults in the Brazilian population-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional da UEL - RIUEL

Não existem arquivos associados a este item.