Determinação sem medição das curvas de consumo e demanda em prédios públicos utilizando programas computacionais

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorMonteiro, Paulo Roberto Duailibe-
Autor(es): dc.contributorTavares, Geraldo Martins-
Autor(es): dc.contributorBorges, Thiago Trezza-
Autor(es): dc.contributorOliveira, Carlos Henriques Ventura do Rosário-
Autor(es): dc.creatorLima, Luan Silva de-
Data de aceite: dc.date.accessioned2025-01-03T11:44:10Z-
Data de disponibilização: dc.date.available2025-01-03T11:44:10Z-
Data de envio: dc.date.issued2024-07-25-
Data de envio: dc.date.issued2024-07-25-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/33656-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/920712-
Descrição: dc.descriptionEste trabalho visa validar os resultados de consumo elétrico de edifícios simulados pelos softwares EnergyPlus e OpenStudio. A validação é realizada comparando os resultados simulados com as medições reais obtidas por um medidor instalado na subestação do edifício. Além disso, este estudo fornece argumentos técnicos para a utilização da simulação como substituto da pré-medição exigida pelo Procel para submissão de projetos ao Programa de Eficiência Energética (PEE). O edifício do Bloco H da Universidade Federal Fluminense na Praia Vermelha foi utilizado como estudo de caso. No OpenStudio, o prédio foi modelado em 3D, incluindo a agenda de utilização e as cargas. A medição foi realizada durante o mês de Novembro, num período de 30 dias. Para prever o consumo elétrico dos meses subsequentes (agosto a dezembro), aplicou-se um modelo de regressão linear correlacionando a potência consumida à temperatura externa. Além disso, somou-se uma carga constante para representar as cargas que não variam com a temperatura. Com isso, a precisão da simulação foi verificada comparando-a com o consumo mensal medido do edifício, fornecendo uma estimativa robusta do consumo energético ao longo dos seis meses-
Descrição: dc.descriptionThis work aims to validate the electrical consumption results of buildings simulated by the EnergyPlus and OpenStudio software. The validation is carried out by comparing the simulated results with real measurements obtained from a meter installed at the building’s substation. Additionally, this study provides technical arguments for using simulation as a substitute for the pre-measurement required by Procel for project submission to the Energy Efficiency Program (PEE). The H Block building of the Fluminense Federal University at Praia Vermelha was used as a case study. In the OpenStudio, the building was modeled in 3D, including the usage schedule and loads. The measurement was conducted during November, over a period of 30 days. To predict the electrical consumption for the following months (August to December), a linear regression model correlating the consumed power to the external temperature was applied. Furthermore, a constant load was added to represent the loads that do not vary with temperature. Thus, the accuracy of the simulation was verified by comparing it with the building’s measured monthly consumption, providing a robust estimate of energy consumption over the six months-
Descrição: dc.description62 f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectEnergyPlus-
Palavras-chave: dc.subjectOpenStudio-
Palavras-chave: dc.subjectEficiência energética-
Palavras-chave: dc.subjectPrédios publicos-
Palavras-chave: dc.subjectConsumo e demanda de energia-
Palavras-chave: dc.subjectEficiência energética-
Palavras-chave: dc.subjectEdifício público-
Palavras-chave: dc.subjectDemanda de energia-
Palavras-chave: dc.subjectEnergy efficiency-
Palavras-chave: dc.subjectPublic buildings-
Palavras-chave: dc.subjectEnergy consumption and demand-
Título: dc.titleDeterminação sem medição das curvas de consumo e demanda em prédios públicos utilizando programas computacionais-
Tipo de arquivo: dc.typeTrabalho de conclusão de curso-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.