Determinação da presa de cimentos obturadores endodônticos usando um novo modelo experimental animal

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorVianna, Gustavo André de Deus Carneiro-
Autor(es): dc.contributorhttp://lattes.cnpq.br/8005271079083909-
Autor(es): dc.contributorSilva, Emmanuel João Nogueira Leal da-
Autor(es): dc.contributorhttp://lattes.cnpq.br/1572297036325408-
Autor(es): dc.contributorOliveira, Henrique Eduardo-
Autor(es): dc.contributorhttp://lattes.cnpq.br/0366567315989831-
Autor(es): dc.contributorSampaio, Gerhilde Callou-
Autor(es): dc.contributorhttp://lattes.cnpq.br/5201713977086831-
Autor(es): dc.contributorZuolo, Mário Luis-
Autor(es): dc.contributorhttp://lattes.cnpq.br/3547709167551949-
Autor(es): dc.contributorBueno, Carlos Eduardo da Silveira-
Autor(es): dc.contributorhttp://lattes.cnpq.br/1251640048302200-
Autor(es): dc.contributorhttp://lattes.cnpq.br/2669571591573095-
Autor(es): dc.creatorKherlakian, Iracema Cabral Ehrhardt-
Data de aceite: dc.date.accessioned2025-01-03T11:41:42Z-
Data de disponibilização: dc.date.available2025-01-03T11:41:42Z-
Data de envio: dc.date.issued2024-07-24-
Data de envio: dc.date.issued2024-07-24-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/33595-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/919968-
Descrição: dc.descriptionOs cimentos à base de Silicato foram introduzidos na endodontia basicamente como cimentos de reparo e obturadores na expectativa de um material com as propriedades positivas do MTA (Agregado Trióxido Mineral) superando sua dificuldade de manipulação sem perder as propriedades biocompatíveis. Eles apresentam propriedades favoráveis como pH alcalino, atividade antibacteriana, radiopacidade, biocompatibilidade e estabilidade dimensional. A despeito dessas vantagens, muitas questões ainda não foram respondidas quanto ao seu desempenho clínico e necessitam de metodologia apropriada para isso, dentre elas, a presa dos cimentos. O objetivo desse estudo é apresentar e explorar o potencial de um modelo experimental animal desenvolvido, para determinar a presa de cimentos obturadores endodônticos in vivo e comparar com os resultados obtidos em experimento paralelo in vitro. O tempo de presa in vitro do AH Plus, Bio-C Sealer, TotalFill BC Sealer e Sealapex foi determinado usando ISO 6876: 2012. Na determinação da presa in vivo, 24 ratos Wistar adultos foram acompanhados por dois períodos de avaliação: uma e quatro semanas. O incisivo superior direito foi extraído, seguido da remoção do tecido pulpar. O canal radicular foi, então, preenchido pela via retrógrada com um dos 4 cimentos, e o dente foi reimplantado e fixado no homólogo com uma camada de resina composta fluida. Após uma e quatro semanas do procedimento cirúrgico, os animais foram sacrificados e seus incisivos superiores direitos foram extraídos. Cortes de 2 mm de espessura do terço médio da raiz do dente foram obtidos e avaliados com um dispositivo Gillmore, para determinar se o cimento havia tomado presa ou não. Os seguintes resultados in vitro foram obtidos pela metodologia ISO 6876: 2012: AH Plus tomou presa, após um tempo médio de 423 ± 20min e 476 ± 35 min, em moldes de metal e gesso, respectivamente. O Bio-C Sealer endureceu após 7 dias (em moldes de gesso odontológico), enquanto o TotalFill BC Sealer e o Sealapex não endureceram, mesmo após 25 dias, em ambas as condições testadas (moldes de metal ou gesso). Usando a nova metodologia in vivo, AH Plus, Bio-C Sealer e TotalFill BC Sealer tomaram presa após 7 e 30 dias. Em contraposição, Sealapex não tomou presa em nenhum dos intervalos de tempo. Conclusões: AH Plus e Bio-C Sealer tomaram presa em condições de teste in vitro e in vivo. O TotalFill BC Sealer não tomou presa sob condições in vitro; mas, nos testes in vivo, a presa ocorreu uma semana após. O Sealapex não tomou presa sob condições in vitro nem in vivo. A influência das condições de teste nos resultados de presa é uma indicação clara de que novos modelos experimentais in vivo serão úteis, em estudos futuros, sobre cimentos endodônticos biocerâmicos.-
Descrição: dc.descriptionSilicate-based cements were introduced in endodontics basically as repair and filling sealers in the expectation of a material with MTA (Mineral Trioxide Aggregate) positive properties overcoming its difficulty in handling without losing biocompatible properties. They have favorable properties such as alkaline pH, antibacterial activity, radiopacity, biocompatibility and dimensional stability. Despite these advantages, many questions remain unanswered regarding its clinical performance and need appropriate methodology criteria for this, like the setting of sealers. The aim of this study is to present and explore the potential of an experimental animal model developed to determine the setting of endodontic sealers in vivo and compare with the results of an in vitro parallel study. The in vitro setting time of the sealers tested was determined in accordance with ISO 6876:2012. In determining the in vivo set, 24 adult Wistar rats were followed up for two evaluation periods: 1 and 4 weeks. Their upper-right incisor was extracted, and its pulp tissue was removed. The root canal was then filled from retrograde with one of the 4 sealers, and the tooth was re-implanted and fixed with a layer of a flowable composite resin. After 1 or 4 weeks of the surgical procedures, the animals were euthanized, and their incisors were extracted. Two-mm-thick slices of the middle third of the tooth root were obtained and assessed with a Gillmore device, to determine whether or not the sealer had set. Results: The following in vitro results were obtained by using ISO 6876:2012 methodology: AH Plus set after a mean time of 423 ± 20 min and 476 ± 35 min, in metal and plaster molds, respectively. Bio-C Sealer set after 7 days (in dental plaster molds), whereas TotalFill BC Sealer and Sealapex did not set even after 25 days in both tested conditions (metal or dental plaster molds). Using the novel in vivo methodology, AH Plus, Bio-C Sealer and Total Fill BC Sealer set after both 7 and 30 days. In contrast, Sealapex did not set at either time point. Conclusions: AH Plus and Bio-C Sealer set under both in vitro and in vivo test conditions. TotalFill BC Sealer did not set under in vitro conditions but did after 1 week under in vivo conditions. Sealapex did not set under either in vitro or in vivo conditions. The influence of the testing conditions on the setting results is a clear indication that the new in vivo experimental models should be useful in future studies on Bioceramics root canal sealers.-
Descrição: dc.description54 f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectAgregado trióxido mineral-
Palavras-chave: dc.subjectCimentos de silicato de cálcio-
Palavras-chave: dc.subjectCimento obturador endodôntico-
Palavras-chave: dc.subjectPropriedades físico-químicas-
Palavras-chave: dc.subjectTempo de presa-
Palavras-chave: dc.subjectCimentos dentários-
Palavras-chave: dc.subjectCimento de silicato-
Palavras-chave: dc.subjectObturação do canal radicular-
Palavras-chave: dc.subjectRato Wistar-
Palavras-chave: dc.subjectTécnicas in vitro-
Palavras-chave: dc.subjectFenômenos físicos-
Palavras-chave: dc.subjectFenômenos químicos-
Palavras-chave: dc.subjectCalcium silicate cements-
Palavras-chave: dc.subjectMineral trioxide aggregate-
Palavras-chave: dc.subjectPhysicochemical properties-
Palavras-chave: dc.subjectRoot canal sealer-
Palavras-chave: dc.subjectSetting time-
Título: dc.titleDeterminação da presa de cimentos obturadores endodônticos usando um novo modelo experimental animal-
Título: dc.titleDetermining the setting of root canal sealers using a new animal experimental model-
Tipo de arquivo: dc.typeTese-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.