Projeto de cobertura metálica aberta com pilares centrais alinhados

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorSchulz, Mauro-
Autor(es): dc.contributorSánchez Filho, Emil de Souza-
Autor(es): dc.contributorMendes, Luiz Carlos-
Autor(es): dc.creatorSilva, Thiago Mourilhe de Oliveira da-
Data de aceite: dc.date.accessioned2025-01-03T11:37:01Z-
Data de disponibilização: dc.date.available2025-01-03T11:37:01Z-
Data de envio: dc.date.issued2024-09-18-
Data de envio: dc.date.issued2024-09-18-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/34741-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/919021-
Descrição: dc.descriptionAs coberturas sem fechamentos laterais com colunas centrais alinhadas são amplamente utilizadas em áreas de carga industrial e em edifícios comerciais que necessitam de livre acesso e circulação, como postos de gasolina. A esbeltez e a geometria dessas estruturas requerem análise e projeto cuidadosos, pois os colapsos são frequentes. Este trabalho apresenta a análise estrutural e o dimensionamento de uma cobertura metálica aberta sem vedações, com uma linha de pilares, localizada em São Paulo. Propostas de alteração do mapa de isopletas de velocidades básicas são discutidas, mas adota-se a ABNT NBR 6123, de dezembro de 2023. A estrutura é dimensionada com o programa Cype 3D (Multiplus, 2021). O programa Advance Steel (Autodesk, 2021) é utilizado para elaborar o projeto das principais ligações, o projeto básico de engenharia e o projeto de fabricação e montagem. Verifica-se a relevância das cargas de vento em coberturas abertas com uma linha de pilares. Três modelos presentes na NBR 6123:2023 são analisados, adotando-se a alternativa mais conservadora. As verificações nos estados limites último e de serviço são atendidas. O estudo mostra que as ligações estão dentro dos limites de resistência. As conexões das colunas com as fundações e das colunas com as vigas principais são críticas e demandam especial atenção. Os desenhos de projeto e de fabricação são apresentados. O trabalho garante a integridade global, a robustez, e a boa execução da estrutura.-
Descrição: dc.descriptionCanopy roofs with aligned central columns are widely used in industrial loading areas and commercial buildings that require free access and circulation, such as gas stations. The slenderness and geometry of these structures necessitate careful analysis and design due to the frequency of collapses. This paper presents the structural analysis and design of an open metal roof without seals, featuring a line of columns, located in São Paulo. While proposals to change the basic velocity isopleth map are discussed, the design adheres to ABNT NBR 6123, from December 2023. The structure is designed using the Cype 3D program (Multiplus, 2021). The Advance Steel program (Autodesk, 2021) is utilized for analyzing the main connections, basic engineering design, and manufacturing and assembly design. The relevance of wind loads on canopy roofs with a line of columns is confirmed. Three models from NBR 6123:2023 are analyzed, with the most conservative alternative adopted. Checks on the ultimate and service limit states are satisfied. The study demonstrates that the connections are within resistance limits. Critical connections, particularly those between columns and foundations and between columns and main beams, require special attention. Design and manufacturing drawings are presented, ensuring the overall integrity, robustness, and proper execution of the structure.-
Descrição: dc.description118 f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectEstruturas metálicas-
Palavras-chave: dc.subjectCoberturas metálicas-
Palavras-chave: dc.subjectCargas de vento-
Palavras-chave: dc.subjectProjeto estrutural-
Palavras-chave: dc.subjectEstrutura metálica-
Palavras-chave: dc.subjectCobertura (Construção)-
Palavras-chave: dc.subjectSteel structures-
Palavras-chave: dc.subjectSteel roofs-
Palavras-chave: dc.subjectWind loads-
Título: dc.titleProjeto de cobertura metálica aberta com pilares centrais alinhados-
Tipo de arquivo: dc.typeTrabalho de conclusão de curso-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF