Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Carvalho, João Luiz Azevedo de | - |
Autor(es): dc.creator | Rispoli, Vinícius de Carvalho | - |
Data de aceite: dc.date.accessioned | 2024-10-23T16:45:07Z | - |
Data de disponibilização: dc.date.available | 2024-10-23T16:45:07Z | - |
Data de envio: dc.date.issued | 2015-04-29 | - |
Data de envio: dc.date.issued | 2015-04-29 | - |
Data de envio: dc.date.issued | 2015-04-29 | - |
Data de envio: dc.date.issued | 2014-12-10 | - |
Fonte completa do material: dc.identifier | http://repositorio.unb.br/handle/10482/18045 | - |
Fonte completa do material: dc.identifier | http://dx.doi.org/10.26512/2014.12.T.18045 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/916392 | - |
Descrição: dc.description | Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2014. | - |
Descrição: dc.description | As doenças cardiovasculares representam hoje uma das maiores causas de morte no mundo. Desta forma, o conhecimento dos padrões de escoamento sanguíneo no corpo humano se faz importante no diagnóstico e pesquisa de algumas doenças. Utilizando a ressonância magnética (RM), o escoamento sanguíneo pode ser mensurado in vivo diretamente usando ressonância magnética (RM) com contraste de fase (CF) ou através da codificação de velocidade em Fourier (CVF). Por outro lado, o escoamento sanguíneo pode também ser simulado utilizando uma abordagem baseada em modelos da dinâmica dos fluidos computacional (DFC). O CF tem como desvantagens os longos tempos de aquisição, a resolução espaço-temporal limitada, efeitos de volume parcial e baixa relação sinal-ruído (SNR). Por outro lado, a codificação de velocidade em Fourier é um método de imageamento por ressonância magnética promissor para realizar medidas do escoamento cardiovascular. A CVF oferece SNR consideravelmente maior que o CF e também é robusto aos efeitos de volume parcial. Os conjuntos de dados com CVF são adquiridos com baixa resolução espacial devido aos longos tempos de aquisição relacionados a sua alta dimensionalidade, (x,y,v,t), mas proporcionam a distribuição de velocidade associada a cada um dos seus grandes voxels. Entretanto, não um mapa de velocidades do escoamento. Finalmente, a DFC proporciona alta resolução temporal e espacial, além de tempos de aquisição reduzidos. Porém a sua acurácia é dependente das hipóteses do modelo. O objetivo deste trabalho é apresentar um método capaz de integrar medidas diretas de RM (CF ou CVF) a um algoritmo para determinar solução das equações da dinâmica dos fluidos, tendo como principal interesse a redução no tempo de exame num ambiente clínico. Desta forma, este trabalho apresenta duas contribuições originais: (i) um método para extrair mapas de velocidade de alta resolução espacial a partir de dados com CVF de baixa resolução espacial; e (ii) um método para reconstruir campos de velocidade que são influenciados ao mesmo tempo pelas medidas diretas por RM (CF ou CVF) e pelos modelos físicos da dinâmica dos fluidos. | - |
Descrição: dc.description | Cardiovascular diseases represents today one of the leading causes of death worldwide. Thus, knowledge of the blood flow patterns in the human body is important for diagnosis and research of certain diseases. Using magnetic resonance (MRI), in vivo 3D blood flow patterns can be either measured directly using phase–contrast (PC) MRI or Fourier velocity encoding (FVE) MRI. On the other hand, blood flow patterns can be obtained from model-based computational fluid dynamics (CFD) calculations. PC–MRI suffers from long scan times, limited spatio–temporal resolution, partial–volume effects and low signal–to–noise ratio (SNR). Fourier velocity encoding (FVE) is a promising magnetic resonance imaging method for measurement of cardiovascular blood flow. FVE provides considerably higher SNR than phase contrast imaging, and is robust to partial–volume effects. FVE data is usually acquired with low spatial resolution, due to scantime restrictions associated with its higher dimensionality, (x; y; v; t), and provides the velocity distribution associated with a large voxel, but does not directly provides a velocity map. Since the acquisition time is a disadvantage of FVE, then, preferably, it should be acquired with rapid spiral trajectories. Finally, CFD provides arbitrarily high spatial and temporal resolution and reduced scan times, but its accuracy hinges on the model assumptions. The objective of this work is to present a method capable of integrate direct MRI (PC or FVE) measures inside a CFD solver on the way to reduce scan time in a clinical environment. This work presents two main original contributions: (i) a method to derive velocity maps with high spatial resolution from low spatial resolution FVE data; and (ii) a numerical framework for constructing a flow field that is influenced by both direct measurements (PC–MRI or FVE) and a fluid physics model. | - |
Formato: dc.format | application/pdf | - |
Direitos: dc.rights | Acesso Aberto | - |
Direitos: dc.rights | A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data. | - |
Palavras-chave: dc.subject | Ressonância magnética | - |
Palavras-chave: dc.subject | Sistema cardiovascular - doenças | - |
Palavras-chave: dc.subject | Sangue - distúrbios de circulação | - |
Palavras-chave: dc.subject | Dinâmica dos fluidos - programas de computador | - |
Palavras-chave: dc.subject | Processamento de imagens | - |
Título: dc.title | Simulações computacionais do escoamento cardiovascular guiadas por ressonância magnética | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional – UNB |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: