Modified Schirmer tear test and rebound tonometry in blue-fronted Amazon parrot (Amazona aestiva)

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorFalcão, Mário Sérgio Almeida-
Autor(es): dc.creatorMonteiro, Rafael V.-
Autor(es): dc.creatorOriá, Arianne Pontes-
Autor(es): dc.creatorGalera, Paula Diniz-
Data de aceite: dc.date.accessioned2024-10-23T16:30:43Z-
Data de disponibilização: dc.date.available2024-10-23T16:30:43Z-
Data de envio: dc.date.issued2018-01-04-
Data de envio: dc.date.issued2018-01-04-
Data de envio: dc.date.issued2017-08-
Fonte completa do material: dc.identifierhttp://repositorio.unb.br/handle/10482/30612-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.1590/s0100-736x2017000800015-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/910313-
Descrição: dc.descriptionO objetivo deste estudo foi descrever o teste lacrimal de Schirmer modificado (TLSm), a pressão intraocular (PIO) pela tonometria de rebote e o comprimento da fissura palpebral (FP) do papagaio-verdadeiro (Amazona aestiva). Foram avaliados 35 papagaios adultos e saudáveis, provenientes de um Criadouro Conservacionista do Brasil. Após avaliação clínica e laboratorial, as aves foram fisicamente contidas para aferição, em ambos os olhos, do TLSm, da PIO pela tonometria de rebote e do comprimento da FP utilizando-se um paquímetro digital. Valor médio do TLSm foi 6.2±0.1mm/min e da PIO foi 6.4±0.1 mmHg, enquanto a aferição da FP foi 10.1±0.1mm. Uma correlação moderada foi observada entre TLSm e a FP para olho direito (OD) (ρ=0.14) e olho esquerdo (OE) (ρ=0.20). Os resultados podem servir como valores de referência para testes oftálmicos para A. aestiva.-
Descrição: dc.descriptionThe aim of this study was to describe the modified Schirmer tear test (mSTT), intraocular pressure (IOP) by rebound tonometry and palpebral fissure length (PFL) in blue-fronted Amazon parrots (Amazona aestiva). Thirty-five healthy adult animals from a conservation breeding center in Brazil were used in this study. Modified Schirmer tear test, rebound tonometry and PFL measurements were performed in both eyes, with birds under physical restraint. Mean mSTT was 6.2±0.1mm/min and mean IOP was 6.4±0.1mmHg, while PFL was 10.1±0.1mm. A moderate correlation was seen between mSTT and PFL for OD (ρ=0.14) and OS (ρ=0.20). The results provide ophthalmic tests reference values for A. aestiva.-
Descrição: dc.descriptionFaculdade de Agronomia e Medicina Veterinária (FAV)-
Formato: dc.formatapplication/pdf-
Idioma: dc.languageen-
Publicador: dc.publisherColégio Brasileiro de Patologia Animal - CBPA. Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA)-
Direitos: dc.rightsAcesso Aberto-
Direitos: dc.rightsPesquisa Veterinária Brasileira - This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY NC 4.0). Fonte: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-736X2017000800871&lng=en&nrm=iso. Acesso em: 20 fev. 2018.-
Palavras-chave: dc.subjectTonometria-
Palavras-chave: dc.subjectPapagaio (Ave)-
Palavras-chave: dc.subjectAve-
Palavras-chave: dc.subjectAparelho lacrimal-
Palavras-chave: dc.subjectPressão intra-ocular-
Palavras-chave: dc.subjectAnimais silvestres-
Título: dc.titleModified Schirmer tear test and rebound tonometry in blue-fronted Amazon parrot (Amazona aestiva)-
Título: dc.titleTeste lacrimal de Schirmer modificado e tonometria de rebote em papagaio-verdadeiro (Amazona aestiva)-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional – UNB

Não existem arquivos associados a este item.