Contaminação bacteriana da câmara anterior pós-facoemulsificação com implante de lente intra-ocular de polimetilmetacrilato ou silicone

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorPereira, Ricardo Antonio-
Autor(es): dc.creatorSantos, Regina Candido Ribeiro dos-
Autor(es): dc.creatorSantos, Procópio Miguel dos-
Data de aceite: dc.date.accessioned2024-10-23T16:21:31Z-
Data de disponibilização: dc.date.available2024-10-23T16:21:31Z-
Data de envio: dc.date.issued2017-12-07-
Data de envio: dc.date.issued2017-12-07-
Data de envio: dc.date.issued2004-
Fonte completa do material: dc.identifierhttp://repositorio.unb.br/handle/10482/26113-
Fonte completa do material: dc.identifierhttps://dx.doi.org/10.1590/S0004-27492004000600013-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/906390-
Descrição: dc.descriptionOBJETIVO: Avaliar a contaminação bacteriana da câmara anterior, após facoemulsificação não complicada, com tamanhos diferentes de incisões e lentes intra-oculares. MÉTODOS: Foi realizado estudo prospectivo randomizado, de 80 olhos de 80 pacientes, submetidos à facoemulsificação sob anestesia tópica, distribuídos aleatoriamente em dois grupos iguais. No grupo A foram alocados os pacientes submetidos à cirurgia com incisão de 3,0 mm, lente intra-ocular dobrável de silicone implantadas com injetor. No grupo B os pacientes foram submetidos à cirurgia com incisão de 5,8 mm e implante de lente intra-ocular de polimetilmetacrilato de peça única, com pinça. Ao final de cada cirurgia, uma amostra do líquido da câmara anterior foi colhida e semeada em meios de cultura para bactérias. RESULTADOS: A cultura do líquido da câmara anterior foi positiva em 2,5% dos casos do grupo A e em 5,0% do grupo B. Não houve diferença estatisticamente significante entre os dois grupos (chi2 = 0, 380, p> 0,05). CONCLUSÃO: O implante de lente intra-ocular através de incisão menor, não resultou em menor contaminação da câmara anterior na cirurgia de facoemulsificação.-
Descrição: dc.descriptionPURPOSE: To evaluate bacterial anterior chamber contamination following uncomplicated phacoemulsification with differents sizes of incisions. METHODS: Prospective randomized study, 80 eyes, 80 patients divided into two groups, were submitted to phacoemulsification with topical anaesthesia. In group A, with 40 patients, surgery was perfomed with 3.0 mm incision and silicone intraocular lens implant with injector. In group B the surgery was done with 5.8 mm incision and polymethylmethacrylate intraocular lens implant with forceps. Anterior chamber aspirate was taken for culture upon completion of surgery in each case. RESULTS: Anterior chamber cultures were positive in 2.5% of the cases in group A, and 5.0% in group B (chi-square test = 0.380, p>0.05), frequencies of contamination were not significantly different. CONCLUSION: Intraocular lens implant through a smaller incision did not decrease anterior chamber contamination in phacoemulsification.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Publicador: dc.publisherConselho Brasileiro de Oftalmologia-
Direitos: dc.rightsAcesso Aberto-
Direitos: dc.rightsArquivos Brasileiros de Oftalmologia - This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY NC). Fonte: https://www.scielo.br/j/abo/a/hVj9BDcgc5CJdc7SkRvXzdR/?lang=pt#. Acesso em: 10 ago. 2021.-
Palavras-chave: dc.subjectCatarata-
Palavras-chave: dc.subjectFacoemulsificação-
Palavras-chave: dc.subjectLentes intra-oculares - implante-
Palavras-chave: dc.subjectOlhos - infecções-
Título: dc.titleContaminação bacteriana da câmara anterior pós-facoemulsificação com implante de lente intra-ocular de polimetilmetacrilato ou silicone-
Título: dc.titleBacterial anterior chamber contamination after phacoemulsification and polymethylmethacrylate or silicone intraocular lens implantation-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional – UNB

Não existem arquivos associados a este item.