Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.creator | Resende, Jefferson G. | - |
Autor(es): dc.creator | Menezes, Cristiane G. | - |
Autor(es): dc.creator | Paula, Ana M. C. | - |
Autor(es): dc.creator | Ferreira, Antonio C. P. | - |
Autor(es): dc.creator | Zaconeta, Carlos Alberto Moreno | - |
Autor(es): dc.creator | Silva, César A. M. | - |
Autor(es): dc.creator | Rodrigues, Marcelo P. | - |
Autor(es): dc.creator | Tavares, Paulo | - |
Data de aceite: dc.date.accessioned | 2024-10-23T16:16:25Z | - |
Data de disponibilização: dc.date.available | 2024-10-23T16:16:25Z | - |
Data de envio: dc.date.issued | 2017-12-07 | - |
Data de envio: dc.date.issued | 2017-12-07 | - |
Data de envio: dc.date.issued | 2006 | - |
Fonte completa do material: dc.identifier | http://repositorio.unb.br/handle/10482/26572 | - |
Fonte completa do material: dc.identifier | https://dx.doi.org/10.1590/S0021-75572006000600009 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/904178 | - |
Descrição: dc.description | OBJETIVO: Avaliar o pico de pressão inspiratória e a freqüência ventilatória obtidos por médicos quando da utilização de balão auto-inflável neonatal em modelo de pulmão. MÉTODOS: Quinze médicos ventilaram simuladores de pulmão de recém-nascidos a termo e pré-termo, sendo os desfechos captados através de um monitor de ventilação. RESULTADOS: As medianas dos picos de pressão foram 23 (intervalo interquartil, 15-47) e 26 (intervalo interquartil, 14-51) cmH2O, sendo menor que 20 em 41,2 e 35,8% das vezes; maior que 40 em 29,7 e 33,6% das vezes e entre 27 e 33 cmH2O em 8,2 e 6,5% das vezes, para o pulmão de termo e de pré-termo, respectivamente. As medianas das freqüências ventilatórias foram de 45 (intervalo interquartil, 36-57) e 48 (intervalo interquartil, 39-55,5) ciclos por minuto, sendo menor que 30 em 9,3 e 6,7% das vezes e maior que 60 em 12 e 13,3% das vezes, respectivamente, para o pulmão de termo e de pré-termo. As diferenças nas medianas não foram estatisticamente significantes. CONCLUSÃO: A ventilação utilizando o balão auto-inflável promoveu adequação para a freqüência ventilatória em aproximadamente 80% das vezes, e os médicos não conseguiram promover ventilação com mínima variabilidade na pressão, alcançando níveis diferentes daqueles definidos no curso de reanimação neonatal em 70% das vezes. Essa situação independeu da ventilação do pulmão-teste análogo ao sistema respiratório de recém-nascidos a termo ou pré-termo. | - |
Descrição: dc.description | OBJECTIVE: To evaluate the peak inspiratory pressure and ventilation rate achieved by physicians when using a neonatal self-inflating bag on a lung model. METHODS: Fifteen physicians ventilated full term and preterm infant lung simulators while the outcomes were captured by a ventilation monitor. RESULTS: Median peak pressures in cmH2O for full term and preterm lungs were 23 (interquartile range: 15-47) and 26 (interquartile range: 14-51), being less than 20 in 41.2 and 35.8% of the pressure curves analyzed, more than 40 in 29.7 and 33.6%, and between 27 and 33 cmH2O in 8.2 and 6.5% of the curves, respectively. Median ventilation rates were 45 (interquartile range: 36-57) and 48 (interquartile range: 39-55.5) cycles per minute, being more than 30 in 9.3 and 6.7% of pressure curves and more than 60 in 12 and 13.3% of pressure curves, for the full term and preterm lungs, respectively. The differences between these medians were not statistically significant. CONCLUSIONS: Ventilation rates achieved with the self-inflating bag were adequate in approximately 80% of pressure curves analyzed, but the physicians were unable to provide ventilation with minimal pressure variation, producing pressures that diverged from those defined by the neonatal resuscitation training course in 70% of the curves. This was irrespective of whether they were ventilating the lung model analogous to preterm or full term infant lungs. | - |
Descrição: dc.description | Em processamento | - |
Formato: dc.format | application/pdf | - |
Idioma: dc.language | pt_BR | - |
Publicador: dc.publisher | Sociedade Brasileira de Pediatria | - |
Direitos: dc.rights | Acesso Aberto | - |
Palavras-chave: dc.subject | Ressuscitação cardiopulmonar | - |
Palavras-chave: dc.subject | Ventilação pulmonar | - |
Palavras-chave: dc.subject | Ventilação mecânica | - |
Palavras-chave: dc.subject | Recém-nascidos | - |
Palavras-chave: dc.subject | Asfixia neonatal | - |
Título: dc.title | Avaliação do pico de pressão e da freqüência respiratória durante o uso de balão auto-inflável em um modelo de pulmão neonatal | - |
Título: dc.title | Evaluation of peak inspiratory pressure and respiratory rate during ventilation of an infant lung model with a self-inflating bag | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional – UNB |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: