Autor(es): dc.contributor | Silva, Kleber Melo e | - |
Autor(es): dc.creator | Gama, Letícia Almeida | - |
Data de aceite: dc.date.accessioned | 2024-10-23T16:14:45Z | - |
Data de disponibilização: dc.date.available | 2024-10-23T16:14:45Z | - |
Data de envio: dc.date.issued | 2017-08-30 | - |
Data de envio: dc.date.issued | 2017-08-30 | - |
Data de envio: dc.date.issued | 2017-08-30 | - |
Data de envio: dc.date.issued | 2017-05-04 | - |
Fonte completa do material: dc.identifier | http://repositorio.unb.br/handle/10482/24355 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/903459 | - |
Descrição: dc.description | Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2017. | - |
Descrição: dc.description | Este trabalho apresenta a análise das trajetórias do elemento diferencial convencional no plano alfa, juntamente com a análise de um elemento diferencial incremental. A dedução analítica dos elementos de fase convencional e incremental, assim como a dedução dos elementos de sequência zero e negativa, é desenvolvida. Para avaliar o desempenho do algoritmo de proteção são realizadas análises transitórias, utilizadas para avaliar o comportamento da proteção principalmente durante a fase de transição entre a pré-falta e a falta, e análises de sensibilidade paramétrica, nas quais é possível avaliar a influência dos parâmetros do sistema elétrico durante o regime permanente de falta por meio das trajetórias no plano alfa. Estas análises foram realizadas por meio do software Alternative Transients Program (ATP) e considerando um sistema de uma linha de transmissão de 500 kV de 200 km de extensão. O sistema teste é simulado em várias condições de falta, para as quais, os parâmetros variam em uma ampla faixa de valores. Em geral são analisados os seguintes parâmetros: carregamento do sistema, força das fontes utilizando a variável SIR, resistência de falta, assim como a localização e os tipos de faltas. Os resultados obtidos evidenciam as vantagens do elemento incremental proposto, e confirmam o comportamento eficiente e apropriado exibido pelo algoritmo. Através destes resultados conclui-se que o algoritmo proposto pode se tornar uma alternativa segura para a proteção de linhas de transmissão. | - |
Descrição: dc.description | This work presents an analysis of the trajectories of the conventional differential element on the alpha plane, along with the analysis of a incremental differential element. The analytical deduction of the conventional and incremental phase elements, as well as the deduction of the zero and negative sequence elements is developed. In order to evaluate the performance of the protection algorithm, it is performed transient analyzes, used to evaluate the protection behavior mostly through the transition between the pre fault and fault periods, and parametric sensitivity analyzes, in which it is possible to evaluate the influence of the electrical system parameters during the fault steady state through the trajectories in the alpha plane. These analyzes were carried out using the software Alternative Transients Program (ATP) and considering a 500 kV 200 km long transmission line system. The test system is simulated under several fault conditions in which, the parameters vary over a wide range of values. In general, system loading, source strength using the SIR variable, fault resistance, as well as location and types of faults were analyzed. The obtained results attest the advantages of the proposed incremental element, and confirm the efficient and appropriate behavior exhibited by the algorithm. Through these results it is concluded that the proposed algorithm can become a safe alternative for the protection of transmission lines. | - |
Descrição: dc.description | Faculdade de Tecnologia (FT) | - |
Descrição: dc.description | Departamento de Engenharia Elétrica (FT ENE) | - |
Descrição: dc.description | Programa de Pós-Graduação em Engenharia Elétrica | - |
Formato: dc.format | application/pdf | - |
Direitos: dc.rights | Acesso Aberto | - |
Direitos: dc.rights | A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data. | - |
Palavras-chave: dc.subject | Proteção diferencial - análise | - |
Palavras-chave: dc.subject | Linhas de transmissão - proteção diferencial | - |
Palavras-chave: dc.subject | Plano Alfa | - |
Título: dc.title | Proteção diferencial incremental de linhas de transmissão no Plano Alfa | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional – UNB |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: