Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.creator | Cayo, Eber Huanca | - |
Autor(es): dc.creator | Alfaro, Sadek Crisóstomo Absi | - |
Data de aceite: dc.date.accessioned | 2024-10-23T16:12:54Z | - |
Data de disponibilização: dc.date.available | 2024-10-23T16:12:54Z | - |
Data de envio: dc.date.issued | 2012-10-02 | - |
Data de envio: dc.date.issued | 2012-10-02 | - |
Data de envio: dc.date.issued | 2009-09 | - |
Fonte completa do material: dc.identifier | http://repositorio.unb.br/handle/10482/11338 | - |
Fonte completa do material: dc.identifier | https://dx.doi.org/10.3390/s90907150 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/902676 | - |
Descrição: dc.description | Most of the inspection methods used for detection and localization of welding disturbances are based on the evaluation of some direct measurements of welding parameters. This direct measurement requires an insertion of sensors during the welding process which could somehow alter the behavior of the metallic transference. An inspection method that evaluates the GMA welding process evolution using a non-intrusive process sensing would allow not only the identification of disturbances during welding runs and thus reduce inspection time, but would also reduce the interference on the process caused by the direct sensing. In this paper a non-intrusive method for weld disturbance detection and localization for weld quality evaluation is demonstrated. The system is based on the acoustic sensing of the welding electrical arc. During repetitive tests in welds without disturbances, the stability acoustic parameters were calculated and used as comparison references for the detection and location of disturbances during the weld runs. | - |
Formato: dc.format | application/pdf | - |
Publicador: dc.publisher | MDPI | - |
Direitos: dc.rights | Acesso Aberto | - |
Direitos: dc.rights | All articles published by MDPI are made available under an open access license worldwide immediately. This means: everyone has free and unlimited access to the full-text of all articles published in MDPI journals, and everyone is free to re-use the published material given proper accreditation/citation of the original publication, open access publication is supported by authors' institutes or research funding agency by payment of a comparatively low Article Processing Charge (APC) for accepted articles. Fonte: http://www.mdpi.com/about/openaccess. Acesso em: 28 set. 2012. | - |
Palavras-chave: dc.subject | Solda e soldagem | - |
Palavras-chave: dc.subject | Soldagem | - |
Palavras-chave: dc.subject | Soldagem elétrica | - |
Título: dc.title | A non-intrusive GMA welding process quality monitoring system using acoustic sensing | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional – UNB |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: