Influência do parâmetro H/w sobre o auto amortecimento de cabos condutores de energia

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorFerreira, Jorge Luiz de Almeida-
Autor(es): dc.creatorMiranda, Thiago Barbosa de-
Data de aceite: dc.date.accessioned2024-10-23T15:56:14Z-
Data de disponibilização: dc.date.available2024-10-23T15:56:14Z-
Data de envio: dc.date.issued2017-10-24-
Data de envio: dc.date.issued2017-10-24-
Data de envio: dc.date.issued2017-10-24-
Data de envio: dc.date.issued2017-08-04-
Fonte completa do material: dc.identifierhttp://repositorio.unb.br/handle/10482/24871-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/895814-
Descrição: dc.descriptionDissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2017.-
Descrição: dc.descriptionNesse trabalho foi realizada uma comparação do auto amortecimento dos cabos condutores Tern, Orchid e CAL 900, tendo como parâmetro de avaliação a relação H/w. Para tal, foram geradas curvas de auto amortecimento, a partir do Método da Potência, para os três cabos em níveis de H/w de 1820 m, 2144 m e 2725 m, considerando três diferentes frequências de excitação e cinco amplitudes de deslocamento. Foi avaliado a influência da frequência e amplitude de vibração no auto amortecimento de cada cabo condutor, sendo observado um crescimento exponencial da potência dissipada com a variação desses parâmetros. Foi feita uma comparação entre as curvas de potência dissipada dos diferentes cabos, quando submetidos as mesmas condições de vibração e nível de H/w, o cabo condutor Tern obteve o maior auto amortecimento, o CAL 900 obteve valores intermediários e o Orchid teve os menores valores de potência em todos os ensaios. Finalmente, foi realizada uma correlação entre o auto amortecimento e vida em fadiga dos cabos condutores na linha de transmissão quando submetidos as mesmas condições dos ensaios experimentais, nesse estudo o cabo Orchid apresentou o melhor resultado para o caso analisado e o cabo CAL 900 teve um resultado inferior aos demais, apresentando uma estimativa de vida menor que os demais.-
Descrição: dc.descriptionIn this work, a comparison of the self-damping of the overhead conductors Tern, Orchid and CAL 900 was carried out, using the H/w ratio as an evaluation parameter. Therefore, the self-damping curves were generated using the Power Method for the three cables at H/w levels of 1820 m, 2144 m and 2725 m, and considering three different excitation frequencies at five different displacement amplitudes for each H/w level. The influence of the frequency and amplitude of vibration on the self-damping of each conductor was evaluated. One could observe an exponential growth of the power dissipated with the variation of these parameters. Additionally, a comparison between the power-dissipated curves of the different cables was made considering the same conditions of vibration and H/w level. The Tern conductor cable has a higher self-damping value meanwhile the CAL 900 presents an intermediate value and the Orchid has a lower values for all tests. Finally, a correlation between the self-damping and fatigue life of the cables in the transmission line when subject to the same conditions of the experimental tests were submitted. In this study Orchid cable presented a good result for the analyzed case and the cable CAL 900 has a bad result to the others, presenting a smaller life estimate than the others.-
Descrição: dc.descriptionFaculdade de Tecnologia (FT)-
Descrição: dc.descriptionDepartamento de Engenharia Mecânica (FT ENM)-
Descrição: dc.descriptionPrograma de Pós-Graduação em Ciências Mecânicas-
Formato: dc.formatapplication/pdf-
Direitos: dc.rightsAcesso Aberto-
Direitos: dc.rightsA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.-
Palavras-chave: dc.subjectLinhas de transmissão-
Palavras-chave: dc.subjectCabos condutores-
Palavras-chave: dc.subjectAmortecimento (Mecânica)-
Palavras-chave: dc.subjectPotência dissipada-
Título: dc.titleInfluência do parâmetro H/w sobre o auto amortecimento de cabos condutores de energia-
Tipo de arquivo: dc.typelivro digital-