Sistematização de procedimentos e algoritmos para o cálculo da velocidade de condução

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorNascimento, Francisco Assis de Oliveira-
Autor(es): dc.contributorCarmo, Jake Carvalho do-
Autor(es): dc.creatorSilva, Ana Paula Bernardi da-
Data de aceite: dc.date.accessioned2024-10-23T15:54:33Z-
Data de disponibilização: dc.date.available2024-10-23T15:54:33Z-
Data de envio: dc.date.issued2016-03-29-
Data de envio: dc.date.issued2016-03-29-
Data de envio: dc.date.issued2016-03-29-
Data de envio: dc.date.issued2015-12-15-
Fonte completa do material: dc.identifierhttp://repositorio.unb.br/handle/10482/19800-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.26512/2015.12.T.19800-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/895148-
Descrição: dc.descriptionTese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2015.-
Descrição: dc.descriptionA Velocidade de Condução (VC) é um parâmetro fisiológico básico que fornece informações sobre o sistema neuromuscular, utilizada para identificar fadiga e patologias. Este trabalho propõe algoritmos para o cálculo da VC no domínio temporal e uma sistematização de procedimentos para otimizar o seu cálculo. Dado um arranjo linear de sinais Eletromiográficos de Superfície (EMGS), a sistematização proposta consiste de três etapas distintas: (i) seleção dos canais que serão utilizados no cálculo; (ii) aplicação do denoising para minimização do ruído branco gaussiano nos canais selecionados; e (iii) cálculo da velocidade de condução. Na primeira etapa é apresentado um método (independente da intervenção humana) para selecionar os canais de um sinal de EMGS que representem o fenômeno desejado e que sejam similares. Esta seleção é realizada utilizando a distribuição do espectro de frequência dos sinais no intervalo de frequência útil. Na segunda etapa são propostos dois parâmetros de limiariarização para o denoising invariante ao deslocamento que minimizem o ruído branco obtidos de um processo experimental exaustivo. Nesta etapa, também é apresentado um comparativo de desempenho dos métodos e parâmetros mais conhecidos de limiarização utilizados no denoising com os aqui propostos. Na terceira etapa a VC é estimada, por meio de dois algoritmos no domínio temporal, que descrevem o parâmetro como uma dispersão de valores instantâneos. Um dos métodos utiliza o deslocamento dos potenciais de ação respectivos em diferentes canais. O segundo método calcula o coeficiente angular entre um conjunto de canais. O método proposto para a etapa seleção de canais apresentou aproximadamente 98% de correta classificação dos sinais. Não há como comparar este resultado, pois não foi encontrado trabalho similar. Na etapa referente a aplicação do Denoising foi constatado que, para os sinais utilizados neste trabalho, os limiares clássicos SURE e Hibrido apresentam os maiores valores de RSR. O limiar 1, proposto neste trabalho apresentou resultados bem semelhantes aos otimizadores clássicos. Os métodos propostos para o cálculo da VC não necessitaram de utilização de canais consecutivos. As dispersões apresentadas para representar a VC apontaram que existe uma variação do parâmetro ao longo do tempo. As etapas da sistematização se mostraram essenciais para reduzir as limitações de um método de cálculo da VC no domínio temporal.-
Descrição: dc.descriptionThe conduction velocity (CV) is a basic physiological parameter that measures how fast an electrochemical impulse propagates through the neuromuscular system. The CV parameter is used to identify fatigue and pathologies, for instance. This work deals with novel algorithms to infer conduction velocity of white fiber in the time domain. Also, I propose a systematization process in order to estimate the conduction velocity which minimizes the inherent drawbacks of the time domain. Taken a linear arrange of skin surface electromyographic signals (EMGS) the proposed systematization has three distinct stages: (i) channel selection that are utilized for the calculation; (ii) denoising to minimize white Gaussian noise (AWGN) of the selected channels; and (iii) the conduction velocity estimation itself. In the first stage, a method (free from human intervention) that selects the channel of the EMG signal which are representative of the expected phenomenon and are also similar, is presented. In the second stage, I propose two thresholds for denoising were proposed, which are invariant to the displacement that minimizes AWGN. Also, in this stage, I compare the proposed methods with standart methods in the current literature. In the last stage, the conduction velocity is estimated by means of a time domain pair of algorithms, which describe the parameter as a dispersion of the real time values. The first algorithms uses the delay of action potentials on difference channels. The second method computes the slope between a set of channels. Results: The proposed method for channel selection step has approximately a 98% correct classification of signals. There is no way to compare this outcome because it was not found similar work. The classical thresholds SURE and Hybrid showed the highest SNR (Signal Noise Ratio) values for signals used in this work. The first threshold, proposed in this work showed very similar results to classic optimizers. The methods proposed for the calculating the CV does not require the use of consecutive channels. Dipersions presented to represent the result of CV showed that there is a variation of the parameter over time. The stages of systematization proved essencial to reduce the limitations of a CV estimation in the time domain.-
Formato: dc.formatapplication/pdf-
Direitos: dc.rightsAcesso Aberto-
Direitos: dc.rightsA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.-
Palavras-chave: dc.subjectVelcidade de condução-
Palavras-chave: dc.subjectEletromiografia de superfície-
Palavras-chave: dc.subjectDenoising-
Palavras-chave: dc.subjectSistema neuromuscular-
Título: dc.titleSistematização de procedimentos e algoritmos para o cálculo da velocidade de condução-
Título: dc.titleSistematization and algorithms for conduction velocity calculation-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional – UNB

Não existem arquivos associados a este item.