An integrated design process in practice : a nearly zero energy building at the University of Brasília - Brazil

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorAmorim, Cláudia Naves David-
Autor(es): dc.creatorSilva, Joára Cronemberger Ribeiro-
Autor(es): dc.creatorSilva, Caio Frederico e-
Autor(es): dc.creatorGóes, Thiago Montenegro-
Autor(es): dc.creatorMedeiros, Ayana Dantas de-
Autor(es): dc.creatorPimenta, João Manoel Dias-
Autor(es): dc.creatorEgito, Marco Antonio-
Autor(es): dc.creatorBauchspiess, Adolfo-
Autor(es): dc.creatorVelasco, Loana Nunes-
Autor(es): dc.creatorMorales Sánchez, José Manoel-
Data de aceite: dc.date.accessioned2024-10-23T15:51:03Z-
Data de disponibilização: dc.date.available2024-10-23T15:51:03Z-
Data de envio: dc.date.issued2022-10-19-
Data de envio: dc.date.issued2022-10-19-
Data de envio: dc.date.issued2021-
Fonte completa do material: dc.identifierhttps://repositorio.unb.br/handle/10482/45052-
Fonte completa do material: dc.identifierhttp://dx.doi.org/10.5772/intechopen.102443-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/893618-
Descrição: dc.descriptionThis study aims to present the design experience of LabZERO|UnB, an NZEB building awarded in a public call, that will be built on the University of Brasília campus. The method consisted of defining the design team and the Integrated Design Process (IDP), establishing assumptions and design guidelines, schematic design, initial computer simulations, design development, new simulations, and final calculations for the synthesis of energy performance. As a result, IDP proved to be efficient and underlined the possibility of translating research experiences into practice. The barriers and potentialities related to the coordination of a multidisciplinary team stand out, likewise the organization, planning, and achievement of goals. In the design concept of the 200m2 building, the basic assumption was the adequacy of the architecture to favor the use of passive resources, respecting the local climate, classified as high-altitude tropical climate. Moreover, bioclimatic strategies were used, such as the North/South orientation of main façades, narrow floor plan, limited windowwall ratio, and adequate construction materials, to optimize energy consumption. As a result, the distributed generation of electricity was estimated at 58.29 kWh/m2. a year and the final electricity demand was 34.29 kWh/m2. year. Hence, this process indicates the real possibility of reaching the zero energy balance.-
Descrição: dc.descriptionFaculdade de Arquitetura e Urbanismo (FAU)-
Descrição: dc.descriptionDepartamento de Tecnologia em Arquitetura e Urbanismo (FAU TEC)-
Formato: dc.formatapplication/pdf-
Publicador: dc.publisherIntechOpen-
Direitos: dc.rightsAcesso Aberto-
Direitos: dc.rights(CC BY) Individual chapters of this publication are distributed under the terms of the Creative Commons Attribution 3.0 Unported License which permits commercial use, distribution and reproduction of the individual chapters, provided the original author(s) and source publication are appropriately acknowledged. If so indicated, certain images may not be included under the Creative Commons license. In such cases users will need to obtain permission from the license holder to reproduce the material. More details and guidelines concerning content reuse and adaptation can be found at http://www.intechopen.com/copyright-policy.html.-
Palavras-chave: dc.subjectBalanço energético nulo-
Palavras-chave: dc.subjectProjeto integrado-
Palavras-chave: dc.subjectSimulação (Computadores)-
Palavras-chave: dc.subjectEnergia fotovoltaica-
Título: dc.titleAn integrated design process in practice : a nearly zero energy building at the University of Brasília - Brazil-
Aparece nas coleções:Repositório Institucional – UNB

Não existem arquivos associados a este item.