Estudo de um sistema de geração distribuída a partir de uma usina fotovoltaica de 2.408 kWp conectado a um sistema elétrico de média tensão

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorMelo, Fernando Cardoso-
Autor(es): dc.contributorisabellequeiroz2606@gmail.com-
Autor(es): dc.creatorLopes, Isabelle Queiroz de Oliveira-
Data de aceite: dc.date.accessioned2024-10-23T15:50:06Z-
Data de disponibilização: dc.date.available2024-10-23T15:50:06Z-
Data de envio: dc.date.issued2023-07-12-
Data de envio: dc.date.issued2023-07-12-
Data de envio: dc.date.issued2023-07-12-
Data de envio: dc.date.issued2022-12-01-
Fonte completa do material: dc.identifierhttp://repositorio2.unb.br/jspui/handle/10482/46084-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/893188-
Descrição: dc.descriptionDissertação (mestrado) — Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2022.-
Descrição: dc.descriptionO aumento dos investimentos em todo o mundo na diversificação da matriz energética baseada em fontes renováveis de energia, trouxe a expansão da capacidade instalada da geração distribuída (GD) ao longo dos anos. No Brasil, têm-se como principais fontes de GD a geração fotovoltaica e eólica. Com a diminuição dos preços dos módulos fotovoltaicos e das Unidades de Condicionamento de Potência (UCP) para a geração da energia fotovoltaica e a aplicação de uma política energética adequada, o país tem atraído investimentos públicos e privados para o aproveitamento da energia solar. Dessa forma, o presente trabalho realiza um estudo acerca da contribuição econômica de um sistema de minigeração distribuída, a partir de uma usina fotovoltaica de 2.408 kWp, conectado a um sistema elétrico de média tensão, bem como avalia seus parâmetros técnicos. Após a execução de simulações computacionais utilizando o software SAM, da NREL, constatou-se uma redução no consumo do primeiro ano de 45,72% com a minigeração distribuída em questão. Além disso, o resultado anual de energia obtido por simulação é de 4.382 MWh, um fator de capacidade (FC) de 20,7%, taxa de desempenho (TD) de 82%, rendimento de energia (Yf) de 1.817 kWh/kWp, custo nivelado de energia (LCOE) de R$ 0,18/kWh e um período de retorno de 4,6 anos. Por fim, após o funcionamento da usina fotovoltaica por 8 meses, de abril a novembro de 2022, obtiveram-se os seguintes indicadores reais de desempenho técnicos e econômicos nesse período: produção energética de 2.847 MWh, representando uma diferença de - 4,96% em relação a produção energética teórica simulada nesses referidos meses de operação, um fator de capacidade (FC) de 20,19%, taxa de desempenho (TD) de 83,71%, rendimento de energia (Yf) de 1.182 kWh/kWp e uma redução no consumo da unidade consumidora de 45,24%.-
Descrição: dc.descriptionThe increase in investments around the world in the diversification of the energy matrix based on renewable energy sources, brought the expansion of the installed capacity of distributed generation (DG) over the years. In Brazil, the main sources of DG are photovoltaic and wind generation. With the decrease in the prices of photovoltaic modules and Power Conditioning Units (PCU) for the generation of photovoltaic energy and the application of an adequate energy policy, the country has attracted public and private investments for the use of solar energy. Thus, the present work conducts a study on the economic contribution of a distributed minigeneration system, from a 2,408 kWp photovoltaic plant, connected to a medium voltage electrical system, as well as evaluates its technical parameters. After running computer simulations using NREL's SAM software, the consumer showed a reduction in consumption in the first year of 45.72% with the distributed mini-generation in question. In addition, the annual result of energy obtained by simulation is 4,382 MWh, a capacity factor (CF) of 20.7%, performance ratio (PR) of 82%, energy yield (Yf) of 1,817 kWh/kWp, Levelized Cost of Energy (LCOE) of R$ 0.18/kWh and a payback period of 4.6 years. Finally, after operating the photovoltaic plant for 8 months, from April to November 2022, the following real technical and economic performance indicators were obtained in this period: energy production of 2,847 MWh, representing a difference of 4.96% in in relation to the theoretical energy production simulated in these months of operation, a capacity factor (CF) of 20.19%, performance ratio (PR) of 83.71%, energy yield (Yf) of 1,182 kWh/kWp and a reduction in consumption of the consumer unit of 45.24%.-
Descrição: dc.descriptionFaculdade de Tecnologia (FT)-
Descrição: dc.descriptionDepartamento de Engenharia Elétrica (FT ENE)-
Descrição: dc.descriptionPrograma de Pós-Graduação em Engenharia Elétrica-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsAcesso Aberto-
Direitos: dc.rightsA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.-
Palavras-chave: dc.subjectAnálise econômica-
Palavras-chave: dc.subjectMinigeração distribuída-
Palavras-chave: dc.subjectEnergia elétrica - tarifação-
Palavras-chave: dc.subjectUsinas fotovoltaicas-
Título: dc.titleEstudo de um sistema de geração distribuída a partir de uma usina fotovoltaica de 2.408 kWp conectado a um sistema elétrico de média tensão-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional – UNB