Punching resistance of internal slab-column connections with double-headed shear studs

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorOliveira, Marcos Honorato de-
Autor(es): dc.creatorPereira Filho, M. J. M.-
Autor(es): dc.creatorOliveira, Dênio Ramam Carvalho de-
Autor(es): dc.creatorFerreira, Maurício de Pina-
Autor(es): dc.creatorMelo, Guilherme Sales Soares de Azevedo-
Data de aceite: dc.date.accessioned2024-10-23T15:45:16Z-
Data de disponibilização: dc.date.available2024-10-23T15:45:16Z-
Data de envio: dc.date.issued2017-12-07-
Data de envio: dc.date.issued2017-12-07-
Data de envio: dc.date.issued2013-10-
Fonte completa do material: dc.identifierhttp://repositorio.unb.br/handle/10482/29058-
Fonte completa do material: dc.identifierhttps://dx.doi.org/10.1590/S1983-41952013000500002-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/891116-
Descrição: dc.descriptionA punção é uma forma de ruptura por cisalhamento que pode ocorrer em ligações laje-pilar que pode ser evitada utilizando-se armaduras de cisalhamento na ligação. Este artigo apresenta comparações entre resultados experimentais de 36 ensaios realizados em ligações laje-pilar interno, armadas com conectores de cisalhamento do tipo pino de duas cabeças, populares na América do Norte, Europa e Ásia, com resultados teóricos utilizando as recomendações do ACI 318, NBR 6118, Eurocode 2, além da Teoria da Fissura Crítica de Cisalhamento (TFCC). Para o banco de dados utilizado, o ACI 318 mostrou tendências conservadoras, enquanto que a NBR 6118 mostrou baixo coeficiente de variação, mas um grande número de resultados contra a segurança. Tanto o Eurocode 2, quanto a TFCC apresentaram resultados satisfatórios, com o Eurocode 2 apresentando desempenho ligeiramente superior.-
Descrição: dc.descriptionPunching shear is a brittle failure mode that may occur in slab-column connections, which may be prevented by using shear reinforcement in the slab-column connection. This paper presents comparisons between experimental results of 36 tests in internal slab-column connections with double- headed shear studs, which are largely used in North America, Europe and Asia, with theoretical results using recommendations presented by ACI 318, NBR6118, Eurocode 2 and also the Critical Shear Crack Theory (CSCT).Considering the database used it is possible to observe that ACI 318 presents conservative trends, whereas NBR 6118 showed a low coefficient of variation, but with a large number of unsafe results. Both Eurocode 2 and CSCT showed satisfactory results with Eurocode 2 presenting slightly higher performance.-
Formato: dc.formatapplication/pdf-
Formato: dc.formatapplication/pdf-
Idioma: dc.languageen-
Idioma: dc.languagept_BR-
Publicador: dc.publisherIBRACON - Instituto Brasileiro do Concreto-
Direitos: dc.rightsAcesso Aberto-
Direitos: dc.rightsRevista IBRACON de Estruturas e Materiais - Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons (CC BY 4.0). Fonte:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952013000500002&lng=en&nrm=iso. Acesso em: 26 nov. 2020.-
Palavras-chave: dc.subjectLajes lisas-
Palavras-chave: dc.subjectPunção-
Palavras-chave: dc.subjectConectores de cisalhamento-
Título: dc.titlePunching resistance of internal slab-column connections with double-headed shear studs-
Título: dc.titleResistência à punção de ligações laje-pilar interno com conectores de cisalhamento-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional – UNB

Não existem arquivos associados a este item.