Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Rosa, Suélia de Siqueira Rodrigues Fleury | - |
Autor(es): dc.contributor | Jacobi, Ricardo Pezzuol | - |
Autor(es): dc.creator | Cavalcante, Gilvandson Costa | - |
Data de aceite: dc.date.accessioned | 2024-10-23T15:37:48Z | - |
Data de disponibilização: dc.date.available | 2024-10-23T15:37:48Z | - |
Data de envio: dc.date.issued | 2018-08-27 | - |
Data de envio: dc.date.issued | 2018-08-27 | - |
Data de envio: dc.date.issued | 2018-08-16 | - |
Data de envio: dc.date.issued | 2018-02-26 | - |
Fonte completa do material: dc.identifier | http://repositorio.unb.br/handle/10482/32495 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/887892 | - |
Descrição: dc.description | Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2018. | - |
Descrição: dc.description | Este trabalho consiste no desenvolvimento de um Equipamento Médico Assistencial (EMA) que realiza ablação hepática, por meio de radiofrequência, para tratamento de pacientes com câncer no fígado. No processo de desenvolvimento, vários aspectos foram considerados, tais como: compreensão do comportamento do sinal de saída do EMA por meio de modelagens fenomenológicas (MF) e Identificação de Sistemas (IS), além do comportamento físico do fígado frente a radiofrequência. Para verificar o desempenho do equipamento desenvolvido, os testes de exatidão, monotonicidade e avaliação da qualidade do sinal de saída por meio do Fator de Crista (FC) foram realizados de acordo com a Norma da ABNT - NBR-IEC 60601-2-2 (2013). Os resultados obtidos nos ensaios em laboratório mostraram que os parâmetros avaliados no EMA desenvolvido apresentaram valores melhores que os recomendados pela Norma da ABNT - NBR-IEC 60601-2-2 (2013). Adicionalmente, as funções de transferências obtidas, representaram com alto grau de correlação o comportamento do equipamento. | - |
Descrição: dc.description | This work consists of the development of a Medical Assistance Equipment (MAE) that performs hepatic ablation, by means of radiofrequency, for the treatment of patients with liver cancer. In the development process, several aspects were considered, such as: understanding the behavior of the EMA output signal through phenomenological modeling (MF) and System Identification (IS), in addition to the physical behavior of the liver versus radiofrequency. In order to verify the performance of the developed equipment, the tests of accuracy, monotonicity and evaluation of the quality of the output signal through the Crest Factor (FC) were performed according to the ABNT - NBR - IEC 60601-2-2 (2013). The results obtained in the laboratory tests showed that the parameters evaluated in the developed EMA presented better values than those recommended by the Standard of ABNT - NBR-IEC 60601-2-2 (2013). In addition, the transfer functions obtained represented a high degree of correlation with the behavior of the equipment. | - |
Formato: dc.format | application/pdf | - |
Direitos: dc.rights | Acesso Aberto | - |
Direitos: dc.rights | A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data. | - |
Palavras-chave: dc.subject | Fígado - doenças | - |
Palavras-chave: dc.subject | Fígado - câncer | - |
Palavras-chave: dc.subject | Equipamentos hospitalares | - |
Título: dc.title | Desenvolvimento e avaliação de um equipamento médico assistencial : ablador hepático por radiofrequência – Sofia | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional – UNB |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: