Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.creator | Faria, S. de S. | - |
Autor(es): dc.creator | Souza, P. C. de | - |
Autor(es): dc.creator | Justa, C. F. da | - |
Autor(es): dc.creator | Rosa, S. de S. R. F. | - |
Autor(es): dc.creator | Rocha, Adson Ferreira da | - |
Data de aceite: dc.date.accessioned | 2024-10-23T15:37:15Z | - |
Data de disponibilização: dc.date.available | 2024-10-23T15:37:15Z | - |
Data de envio: dc.date.issued | 2022-07-05 | - |
Data de envio: dc.date.issued | 2022-07-05 | - |
Data de envio: dc.date.issued | 2021 | - |
Fonte completa do material: dc.identifier | https://repositorio.unb.br/handle/10482/44099 | - |
Fonte completa do material: dc.identifier | https://doi.org/10.1007/978-3-030-70601-2_161 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/887655 | - |
Descrição: dc.description | Atrial fibrillation (AF) is a cardiac arrhythmia that affects around 33 million people worldwide. A standard form of treatment for AF is cardiac ablation with the radiofrequency catheter (RFCA). RFCA generates heat through the ablation electrode, and this process can cause severe lesions in the atrial and esophageal tissues. This work presents a two-dimensional computational model that uses geometry and boundary conditions that approximate cardiac ablation conditions with a non-irrigated catheter. The paper’s objective is to simulate the RFCA and analyze the heat propagation during cardiac ablation when the esophageal wall is cooled down. The esophagus, the connective tissue, and the heart wall were simulated, assuming laminar blood flow in the heart wall. The simulated electrode temperatures were 60, 70, and 80 °C for 60 seconds with constant peak voltage. The cooling temperature was 0 °C. The results showed that cooling decreases the temperature between tissues. The temperature in connective-cardiac tissue dropped by approximately 6.51%. In the esophageal-connective tissue, the temperature decreased by about 28.22%. In all cases, there was also a slowing in temperature increase, which can help prevent tissue damage. The results suggest that the method has significant potential for improving the safety of RFCA. | - |
Descrição: dc.description | Faculdade de Tecnologia (FT) | - |
Descrição: dc.description | Departamento de Engenharia Elétrica (FT ENE) | - |
Publicador: dc.publisher | Springer | - |
Direitos: dc.rights | Acesso Restrito | - |
Palavras-chave: dc.subject | Ablação cardíaca | - |
Palavras-chave: dc.subject | Ablação de cateteres | - |
Palavras-chave: dc.subject | Modelação por computador | - |
Palavras-chave: dc.subject | Lesão térmica | - |
Palavras-chave: dc.subject | Arrefecimento esofágico | - |
Título: dc.title | Analysis of the heat propagation during cardiac ablation with cooling of the esophageal wall : a bidimensional computational modeling | - |
Aparece nas coleções: | Repositório Institucional – UNB |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: