Autor(es): dc.contributor | Fernandes, Aline Úrsula Rocha | - |
Autor(es): dc.creator | Lima, Walkiria Mendes de | - |
Data de aceite: dc.date.accessioned | 2024-10-23T15:29:34Z | - |
Data de disponibilização: dc.date.available | 2024-10-23T15:29:34Z | - |
Data de envio: dc.date.issued | 2016-02-18 | - |
Data de envio: dc.date.issued | 2016-02-18 | - |
Data de envio: dc.date.issued | 2016-02-18 | - |
Data de envio: dc.date.issued | 2015-10-27 | - |
Fonte completa do material: dc.identifier | http://repositorio.unb.br/handle/10482/19516 | - |
Fonte completa do material: dc.identifier | http://dx.doi.org/10.26512/2015.10.D.19516 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/884468 | - |
Descrição: dc.description | Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2015. | - |
Descrição: dc.description | Este estudo foi dividido em dois capítulos, o primeiro capítulo objetivou revisar a literatura e estabelecer um comparativo da resistência à tração entre os sistemas de retenção: magneto, barra-clipe e o’ring. A busca foi realizada na base de dados PubMed, utilizando as palavras-chave "prostheses retention, maxillofacial prosthetics, prostheses and implant, traction”. Os critérios de inclusão foram artigos com ano de publicação entre 2005-2015, de pesquisa científica, revisões de literatura, ou ensaios clínicos em inglês. Foram selecionados sete artigos, que traziam em seu conteúdo, a resistência à tração dos sistemas de retenção barra-clipe, o’ring e magneto. Concluiu-se que o sistema de retenção com melhor desempenho de força de tração foi o barra-clipe, seguido do o’ring e magneto. O segundo capítulo foi um estudo in vitro que comparou forças de retenção de três sistemas: o’ring, barra-clipe e magneto, em função da ciclagem mecânica com 2160 ciclos. Os sistemas foram submetidos à análise da resistência à tração pelo equipamento Instron 4411 (USA) antes e após os ciclos mecânicos (1080-2160), realizados no equipamento MTS 810 (USA). Pode-se observar, nos resultados apresentados, que houve diferença estatística significativa, entre o sistema de retenção barra-clipe e os demais. Conclui-se que o sistema barra-clipe apresentou diferença estatística quando comparado à força de retenção do sistema o’ring e magneto. O uso dos três sistemas de retenção estudados está indicado para o uso clínico, sendo que a manutenção do sistema pode não ser necessária até 1080 ciclos. | - |
Descrição: dc.description | This study was divided into two chapters, the first chapter aimed to review the literature and to establish a comparison of the tensile strength of the restraint systems: magnet, bar-clip and O-ring. The search was conducted in the PubMed database, using the keywords "retention prostheses, maxillofacial prosthetics, prostheses and implant, traction". Inclusion criteria were articles with year of publication in 2005-2015, scientific research, revisions literature, or clinical trials in English. We selected seven articles, which brought in its content, the tensile strength of the bar-clip restraint systems, O-ring and magnet. It was concluded that the restraint system with better power performance Draw-bar clip was followed by the O-ring and the second magnet section foium vitro study comparing three systems retention forces:. O-ring, and magneto-bar clip on the basis of mechanical cycling at 2160 cycles . The systems were subjected to analysis of tensile strength by Instron equipment 4411 (USA) before and after the mechanical cycles (1080-2160), conducted in 810 MTS (USA) equipment. It can be seen, in our results, there was statistically significant difference between the restraint bar-clip and others. We conclude that the bar-clip system showed statistically significant differences when compared to the O-ring retention system strength and magnet. The use of the three studied restraint systems are suitable for clinical use, and the system maintenance may be required up to 1080 cycles. | - |
Descrição: dc.description | Faculdade de Ciências da Saúde (FS) | - |
Descrição: dc.description | Programa de Pós-Graduação em Ciências da Saúde | - |
Formato: dc.format | application/pdf | - |
Direitos: dc.rights | Acesso Aberto | - |
Direitos: dc.rights | A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data. | - |
Palavras-chave: dc.subject | Resistência à tração | - |
Palavras-chave: dc.subject | Próteses nasais | - |
Palavras-chave: dc.subject | Implantes | - |
Título: dc.title | Avaliação da resistência à tração de sistemas de retenção para próteses nasais implantorretidas | - |
Título: dc.title | Resistance to retention rate for traction systems implants nasal implantorretidas | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional – UNB |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: