Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Santos, Procópio Miguel dos | - |
Autor(es): dc.creator | Araújo, André Gustavo Rolim de | - |
Data de aceite: dc.date.accessioned | 2024-10-23T15:26:05Z | - |
Data de disponibilização: dc.date.available | 2024-10-23T15:26:05Z | - |
Data de envio: dc.date.issued | 2009-02-26 | - |
Data de envio: dc.date.issued | 2009-02-26 | - |
Data de envio: dc.date.issued | 2008 | - |
Data de envio: dc.date.issued | 2008 | - |
Fonte completa do material: dc.identifier | http://repositorio.unb.br/handle/10482/1351 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/882960 | - |
Descrição: dc.description | Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2008. | - |
Descrição: dc.description | Objetivo: Avaliar clinicamente o desempenho da cirurgia de catarata por facoemulsificação com tecnologia torsional Infiniti Vision SystemTM – OZilTM U/S Torsional® e incisão microcoaxial em córnea clara de 2,2 mm. Métodos: Estudo clínico observacional de 96 olhos com catarata nuclear ou córtico-nuclear grau 2 de acordo com o Sistema de Classificação de Opacidades Lenticulares III, submetidos à cirurgia de facoemulsificação com incisão microcoaxial de 2,2 mm e tecnologia torsional OZiL (OZilTM U/S Torsional® com Infiniti Vision SystemTM no Hospital Oftalmológico de Brasília. Foram analisadas variáveis intra-operatórias de volume de solução salina balanceada (SSB) infundida, tempo cirúrgico (TC) e energia ultra-sônica dissipada acumulada (EDA); variáveis pré e pós-operatórias de um dia e um mês de paquimetria central da córnea (PCC) e densidade de células endoteliais da córnea (DCE). Resultados: Na análise do parâmetro intra-operatório de volume médio de SSB, em ml, utilizado durante a cirurgia, foi de 97,3 com desvio padrão (DP) de ± 9,62. O TC médio foi de 5,08 com DP de ± 0,53. A EDA média dos procedimentos foi de 3,23 com DP de ± 0,39. Os valores médios da PCC, em μm, analisados no pré-operatório, pós-operatório com um dia e um mês foram, respectivamente, 538,98, 545,34 e 541,78 (p-valor 0,05). Os valores médios da DCE, em células por mm2, analisados no pré-operatório, pós-operatório com um dia e um mês foram, respectivamente, 2321, 2281, 2230 (p valor 0,05). A redução percentual da DCE foi de 1,7% no primeiro dia pós-operatório e 4% após um mês da cirurgia. Conclusão: A técnica de facoemulsificação com tecnologia – OZilTM U/S Torsional® e incisão microcoaxial em córnea clara de 2,2 mm parece não afetar prejudicialmente o endotélio corneano, avaliado através dos parâmetros de PCC, DCE, EDA e volume de SSB infundido. _______________________________________________________________________________________ ABSTRACT | - |
Descrição: dc.description | Objective: to clinically evaluate the performance of the phacoemulsification cataract surgery using the torsional technology Infiniti Vision SystemTM - OZilTM U/S Torsional® with 2,2 mm clear corneal microcoaxial incision. Methods: observational clinical study comprising 96 eyes with nuclear or cortico-nuclear cataract grade 2 according to Lens Opacities Classification System III submitted to phacoemulsification cataract surgery using the torsional technology Infiniti Vision SystemTM - OZilTM U/S Torsional® with 2,2 mm clear corneal microcoaxial incision at Hospital Oftalmológico de Brasília. Intra-operative variables of used volume of balanced salt solution, surgical time and accumulated dissipated ultrasound energy were analysed. Pre and one-day and one-month post-operative variables of central corneal thickness and corneal endothelial density were also analysed. Results: the mean volume of used balanced salt solution, in ml, was 97,3 with standard deviation of ± 9,62. The mean surgical time, in minutes, was 5,08 with standard deviation of ± 0,53. The mean accumulated dissipated ultrasound energy was 3,23 with standard deviation of ± 0,39. The pre-operative, one-day and one-month post-operative mean values, in μm, of central corneal thickness were, respectively, 538,98, 545,34 and 541,78 (p value 0,05). The pre-operative, one-day and one-month post-operative mean values of corneal endothelial density, in cells per mm2, were, respectively, 2321, 2281, 2230 (p value 0,05). The percentage decrease in corneal endothelial density at first post-operative day was 1,7% and at first post-operative month was 4%. Conclusion: the phacoemulsification technique with the torsional technology Infiniti Vision SystemTM - OZil TM U/S Torsional® with 2,2 mm clear corneal microcoaxial incision seems not to damage or affect negatively the corneal endothelium as suggested by the variables analysed. | - |
Descrição: dc.description | Faculdade de Ciências da Saúde (FS) | - |
Descrição: dc.description | Programa de Pós-Graduação em Ciências da Saúde | - |
Formato: dc.format | application/pdf | - |
Direitos: dc.rights | Acesso Aberto | - |
Palavras-chave: dc.subject | Catarata | - |
Palavras-chave: dc.subject | Facoemulsificação | - |
Palavras-chave: dc.subject | Distúrbios da visão | - |
Palavras-chave: dc.subject | Cirurgia oftalmológica | - |
Título: dc.title | Estudo clínico observacional da facoemulsificação com ultra-som torsional na microincisão coaxial de 2,2 mm. | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional – UNB |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: