Análise do posicionamento de um absorvedor dinâmico de vibrações em linhas de transmissão de energia elétrica

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorPaula, Aline Souza de-
Autor(es): dc.creatorMaia, Rangel Silva-
Data de aceite: dc.date.accessioned2024-10-23T15:24:09Z-
Data de disponibilização: dc.date.available2024-10-23T15:24:09Z-
Data de envio: dc.date.issued2019-03-12-
Data de envio: dc.date.issued2019-03-12-
Data de envio: dc.date.issued2019-03-12-
Data de envio: dc.date.issued2018-05-25-
Fonte completa do material: dc.identifierhttp://repositorio.unb.br/handle/10482/34146-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/882158-
Descrição: dc.descriptionDissertação (mestrado)—Universidade de Brasília, Faculdade UnB Gama, Programa de Pós-Graduação em Integridade de Materiais da Engenharia, 2018.-
Descrição: dc.descriptionUma das fontes mais comuns de vibração em cabos condutores de transmissão de energia elétrica é a excitação eólica. Como o vento é constante, ele pode levar à fadiga do cabo, diminuindo assim o seu tempo de vida. Geralmente, linhas de transmissões aéreas são projetadas com grande rigor quanto às cargas estáticas. No entanto, para cargas dinâmicas - como incidências de vento - o mesmo rigor não é aplicado. Isso pode levar à falha dos condutores, causando enormes prejuízos econômicos e sociais. Uma das formas de aumentar o tempo de vida é diminuir as vibrações do cabo através de dispositivos chamados de Absorvedores Dinâmicos de Vibração - ADV. O objetivo desse trabalho é investigar o posicionamento de um ADV sob um critério baseado na energia total de vibração do cabo, dando suporte para a redução de amplitudes de vibração em linhas de transmissão existentes, evitando a paralização do fornecimento de energia elétrica para determinadas regiões. Primeiramente, apresenta-se um modelo que descreve o comportamento dinâmico do cabo e, realiza-se uma avaliação de suas frequências e modos naturais de vibração. Os resultados numéricos obtidos nessas etapas foram compatíveis com aqueles analíticos. Em seguida, utilizando elementos finitos, o comportamento do cabo é simulado sem forçamento externo, com forçamento e sem ADV e com forçamento e ADV acoplado. O desempenho do ADV é avaliado através da energia total do sistema e os melhores posicionamentos para o ADV são estabelecidos e comparados com o posicionamento sugerido pela CIGRÉ. Os resultados das simulações mostraram que o posicionamento do ADV de acordo com o método proposto ficaram próximos dos valores calculados pela norma para todas as frequências avaliadas.-
Descrição: dc.descriptionOne of the most usual types of vibration in overhead lines of electrical energy transmission is the aeolian excitations. As the wind is constant, it can lead to cable fatigue, and so decreasing its lifetime. Generally, overhead lines are designed with great accuracy regarding static loads. However, for dynamic loads - as wind incidences - the same accuracy is not applied. This can lead to conductors fail, causing huge economic and social damages. One way to increase the lifetime is decreasing the cable vibrations through mechanisms called Dynamic Vibration Absorbers - DVA. The aim of this work is investigating the performance of a DVA under a criterion based in the total energy of vibration on the cable, to serve as support for the reduction of the vibration amplitudes in the existing overhead lines, avoiding the blackout in some regions. Firstly, it is presented a model which describes the dynamic behavior of the cable and, it is evaluated the natural frequencies and modes. The numerical results obtained was consistent with the analytical ones. Then, using finite element methods - FEM - the cable is simulated without loading, with loading and without DVA and with loading and DVA coupled. The DVA performance is evaluated through the total energy of the system and the better positioning for the DVA are established and compared with the positioning suggested by CIGRÉ. The results of simulations showed the DVA positioning according to the proposed method was close to the CIGRE curves for all the evaluated frequencies.-
Formato: dc.formatapplication/pdf-
Direitos: dc.rightsAcesso Aberto-
Direitos: dc.rightsA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.-
Palavras-chave: dc.subjectCabos elétricos-
Palavras-chave: dc.subjectEnergia elétrica - transmissão-
Palavras-chave: dc.subjectVibração-
Palavras-chave: dc.subjectAmortecimento (Mecânica)-
Palavras-chave: dc.subjectCabos condutores-
Palavras-chave: dc.subjectLinhas de transmissão-
Título: dc.titleAnálise do posicionamento de um absorvedor dinâmico de vibrações em linhas de transmissão de energia elétrica-
Título: dc.titleAnalysis of a DVA positioning on transmission lines of electrical energy-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional – UNB

Não existem arquivos associados a este item.