Sistema para processamento de áudio em aparelhos auditivos baseado em filtros analógicos utilizando a decomposição Wavelet

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorHaddad, Sandro Augusto Pavlik-
Autor(es): dc.creatorRodrigues, Gabriela Meira de Moura-
Data de aceite: dc.date.accessioned2024-10-23T15:21:34Z-
Data de disponibilização: dc.date.available2024-10-23T15:21:34Z-
Data de envio: dc.date.issued2014-08-22-
Data de envio: dc.date.issued2014-08-22-
Data de envio: dc.date.issued2014-08-22-
Data de envio: dc.date.issued2014-02-27-
Fonte completa do material: dc.identifierhttp://repositorio.unb.br/handle/10482/16141-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/881060-
Descrição: dc.descriptionDissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2014.-
Descrição: dc.descriptionA utilização de filtros analógicos da Transformada Wavelet (WT) em um sistema de tratamento de áudio para aparelho auditivo possui vantagens como melhor relação sinal-ruído (SNR), comparadas com outras técnicas de processamento de sinais utilizadas neste tipo de sistema. A relação sinal-ruído (SNR) é maior com esse tipo de tratamento, obtendo ainda melhor resultado ao selecionar a Gaussiana de ordem primeira como filtro da Wavelet. Além disso, devido ao fato de o sistema apresentado ser analógico não há necessidade de implementação de conversores Analógico-Digital (A/D) e Digital-Analógico (D/A). Foram realizados vários testes por diagramas de blocos, utilizando o programa computacional Simulink do MATLAB, com filtros passa-banda, passa-baixa e com todos os filtros da transformada Wavelet, confirmando o bom funcionamento da gaussiana de ordem primeira como filtro da Wavelet. Por fim, foram explanadas as diferenças entre os tipos e intensidades das deficiências auditivas, selecionando o grau moderado (entre 40 e 69 dB Na) para o tratamento com o presente sistema levando em consideração o limiar de dor dependente da frequência, ou seja, o limite máximo suportável pela orelha humana podendo ocorrer danos à estrutura. O som acrescido de ruído foi tratado pelas gaussianas 8,16,32 e 64 e em seguida foi submetido a um amplificador de controle de ganho automático (AGC). Através dos resultados obtidos em simulações elétricas, foi atingida uma melhor Relação Sinal Ruído (SNR), e assim, melhorando a qualidade sonora do sinal processado. ______________________________________________________________________________ ABSTRACT-
Descrição: dc.descriptionThe use of analog filters for Wavelet Transformer in a system for processing audio for hearing aid has advantages, for example, the better Signal Noise Ratio(SNR), comparing to others techniques of signal processing used in this type of system. The signal to noise ratio (SNR) is higher with this type of treatment, still getting better results when treated selecting Gaussian first order as a filter of Wavelet decomposition. Furthermore, the fact that the system is analog, there is no need to implement analog to digital and digital to analog converters. In this work several tests on system level where performed. Using the computation programmer Simulink of MatLab with band-pass filters, low-pass, and all filters of the Wavelet Transform, confirm the suitability of the Gaussian wavelet filter of the first order. The differences between the types and intensities of hearing loss were explained, choosing moderate (between 40 and 69 dB Na) for treatment with this system taking into account the threshold of pain frequency dependent, that is, supportively maximum limit damage to the human ear can occur structure. The sound with a Gaussian noise was addressed by 8, 16, 32 and 64 wavelet scales, and then, was applied to an automatic gain control (AGC) circuit. From the simulated results, we obtained better Signal Noise Ratio (SNR), and thus, improving the sound quality of the processed signal.-
Descrição: dc.descriptionFaculdade UnB Gama (FGA)-
Descrição: dc.descriptionPrograma de Pós-Graduação em Engenharia Biomédica-
Formato: dc.formatapplication/pdf-
Direitos: dc.rightsAcesso Aberto-
Direitos: dc.rightsA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.-
Palavras-chave: dc.subjectImplantes cocleares-
Palavras-chave: dc.subjectAparelhos auditivos-
Palavras-chave: dc.subjectCircuitos integrados-
Palavras-chave: dc.subjectProcessamento de sinais-
Título: dc.titleSistema para processamento de áudio em aparelhos auditivos baseado em filtros analógicos utilizando a decomposição Wavelet-
Título: dc.titleSystem for processing audio for hearing aid based in analog filters using the Wavelet decomposition-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional – UNB

Não existem arquivos associados a este item.