Parametric evaluation of impedance curve in radiofrequency ablation : a quantitative description of the asymmetry and dynamic variation of impedance in bovine ex vivo model

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorFonseca, Ronei Delfino da-
Autor(es): dc.creatorSantos, Paulo Roberto-
Autor(es): dc.creatorMonteiro, Melissa Silva-
Autor(es): dc.creatorFernandes, Luciana Alves-
Autor(es): dc.creatorCampos, Andreia Henrique-
Autor(es): dc.creatorBorges, Dıbio L.-
Autor(es): dc.creatorRosa, Suélia de Siqueira Rodrigues Fleury-
Data de aceite: dc.date.accessioned2024-10-23T15:17:14Z-
Data de disponibilização: dc.date.available2024-10-23T15:17:14Z-
Data de envio: dc.date.issued2021-05-28-
Data de envio: dc.date.issued2021-05-28-
Data de envio: dc.date.issued2021-01-14-
Fonte completa do material: dc.identifierhttps://repositorio.unb.br/handle/10482/41060-
Fonte completa do material: dc.identifierhttps://doi.org/ 10.1371/journal.pone.0245145-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/879288-
Descrição: dc.descriptionRadiofrequency ablation (RFA) is a treatment for liver tumors with advantages over the traditional treatment of surgical resection. This procedure has the shortest recovery time in early stage tumors. The objective of this study is to parameterize the impedance curve of the RFA procedure in an ex vivo model by defining seven parameters (t1/2, tminimum, tend, Zinitial, Z1/2, Zminimum and Zend). Based on these parameters, three performance indices are defined: one to identify the magnitude of impedance curve asymmetry (δ), one Drop ratio (DR) describing the percentage of impedance decrease until the minimum impedance point is reached, and Ascent Ratio (AR) describing the magnitude of increase in impedance from the minimum impedance point to its maximum point. Fifty ablations were performed in a bovine ex vivo model to measure and evaluate the proposed parameters and performance index. The results show that the groups had an average δ of 29.02%, DR of 22.41%, and AR of 545.33% for RFA without the use of saline or deionized solutions. The saline solution and deionized water-cooled groups indicated the correlation of performance indices δ, DR, and AR with the obtained final ablation volume. Therefore, by controlling these parameters and indices, lower recurrence is achieved.-
Formato: dc.formatapplication/pdf-
Publicador: dc.publisherPLoS ONE-
Direitos: dc.rightsAcesso Aberto-
Direitos: dc.rightsCopyright: © 2021 da Fonseca et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.-
Palavras-chave: dc.subjectAblação por radiofrequência-
Palavras-chave: dc.subjectCarcinoma hepatocelular-
Título: dc.titleParametric evaluation of impedance curve in radiofrequency ablation : a quantitative description of the asymmetry and dynamic variation of impedance in bovine ex vivo model-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional – UNB

Não existem arquivos associados a este item.