Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.creator | Barbosa, Daniel Fernandes | - |
Autor(es): dc.creator | Prada, Francisco José Andriotti | - |
Autor(es): dc.creator | Glanner, Maria Fátima | - |
Autor(es): dc.creator | Nóbrega, Otávio de Tolêdo | - |
Autor(es): dc.creator | Córdova, Claudio Olavo de Almeida | - |
Data de aceite: dc.date.accessioned | 2024-10-23T15:16:15Z | - |
Data de disponibilização: dc.date.available | 2024-10-23T15:16:15Z | - |
Data de envio: dc.date.issued | 2012-12-06 | - |
Data de envio: dc.date.issued | 2012-12-06 | - |
Data de envio: dc.date.issued | 2010-04 | - |
Fonte completa do material: dc.identifier | http://repositorio.unb.br/handle/10482/11767 | - |
Fonte completa do material: dc.identifier | http://dx.doi.org/10.1590/S0066-782X2010005000006 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/878840 | - |
Descrição: dc.description | FUNDAMENTO: O teste de Stroop requer que o indivíduo responda a elementos específicos de um estímulo enquanto inibe processos mais automatizados. OBJETIVO: Comparar a reatividade cardiovascular induzida pela versão computadorizada do teste palavra-cor de Stroop - TESTINPACS® com versão tradicional baseada na leitura de palavras impressas. MÉTODOS: A amostra de conveniência foi constituída por 20 mulheres (22,4 ± 4,1 anos). Análises de variância com medidas repetidas foram utilizadas para comparar efeitos principais entre testes (computadorizado, verbal), assim como entre etapas do teste (linha de base, Stroop 1, Stroop 3) das variáveis fisiológicas (pressão arterial, arritmia sinusal respiratória, frequência cardíaca e frequência respiratória). Testes t para amostras pareadas foram utilizados para comparar as médias pressóricas entre o Stroop 3 e a linha de base. Ademais, a magnitude dos efeitos (d') foi estimada a fim avaliar o impacto das diferenças entre as medidas fisiológicas relativas ao Stroop 3 e a linha de base. RESULTADOS: As duas versões do instrumento produziram elevação significativa em frequência cardíaca (p<0,01) e pressão arterial sistólica (p<0,05) quando medidas resultantes do Stroop 3 foram comparadas às de base. Não se verificaram, contudo, diferenças significativas produzidas pelas diferentes versões do teste sobre as demais variáveis investigadas. Estatísticas d' confirmaram a grande magnitude dos efeitos (-1,04 a +1,49) entre as medidas do Stroop 3 e da linha de base. CONCLUSÃO: Conclui-se que a presente versão computadorizada TESTINPACS® do teste de Stroop constitui instrumento útil para induzir reatividade cardiovascular em mulheres. | - |
Descrição: dc.description | BACKGROUND: The Stroop test requires the individual to respond to specific elements of a stimulus, whereas inhibiting more automated processes. OBJECTIVE: To compare the cardiovascular reactivity induced by the computerized version of the Stroop word-color test TESTINPACSTM with the traditional version based on the reading of printed words. METHODS: The sample of convenience consisted of 20 women (22.4 ± 4.1 years). Analyses of variance with repeated measures were used to compare the main effects between the tests (computerized vs verbal), as well as between phases of the test (baseline, Stroop 1, Stroop 3) on the physiological variables (arterial pressure, respiratory sinus arrhythmia, heart failure and respiratory rate). The t tests for paired samples were used to compare the pressure means between Stroop 3 and baseline. Additionally, the magnitude of the effects (d') was estimated in order to assess the impact of the changes in the physiological measurements between Stroop 3 and the baseline. RESULTS: The two versions of the assessment tool caused significant increase in heart rate (p<0.01) and systolic arterial pressure (p<0.05) when the measurements obtained at the Stroop 3 were compared to that of baseline. However, no significant differences were observed regarding the different versions of the test on the other investigated variables. The d' statistics confirmed the high magnitude of the effects (-1.04 to +1.49) between the measurements from the Stroop 3 and the baseline ones. CONCLUSION: It is concluded that the current computerized version (TESTINPACSTM) of the Stroop test constitutes a useful instrument to induce cardiovascular reactivity in women. | - |
Descrição: dc.description | Faculdade UnB Ceilândia (FCE) | - |
Descrição: dc.description | Curso de Saúde Coletiva (FCE-SC) | - |
Formato: dc.format | application/pdf | - |
Formato: dc.format | application/pdf | - |
Formato: dc.format | application/pdf | - |
Publicador: dc.publisher | Sociedade Brasileira de Cardiologia - SBC | - |
Direitos: dc.rights | Acesso Aberto | - |
Direitos: dc.rights | Arquivos Brasileiros de Cardiologia - Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons (Attribution-NonCommercial 3.0 Unported (CC BY-NC 3.0)). Fonte: http://www.scielo.br/scielo.php?script=sci_serial&pid=0066-782X&lng=pt&nrm=iso. Acesso em: 3 dez. 2012. | - |
Palavras-chave: dc.subject | Stress (Fisiologia) - testes | - |
Palavras-chave: dc.subject | Testes neuropsicológicos | - |
Palavras-chave: dc.subject | Efeito do stress | - |
Palavras-chave: dc.subject | Sistema cardiovascular | - |
Título: dc.title | Resposta cardiovascular ao Stroop : comparação entre teste computadorizado e verbal | - |
Título: dc.title | Cardiovascular response to Stroop test : comparison between the computerized and verbal tests | - |
Título: dc.title | Respuesta cardiovascular al Stroop : comparación entre test computarizado y verbal | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional – UNB |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: