Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.creator | Cavalcante, Gilvandson Costa | - |
Autor(es): dc.creator | Lima, Flávio Ferreira | - |
Autor(es): dc.creator | Venturin, Murilo | - |
Autor(es): dc.creator | Jacobi, Ricardo Pezzuol | - |
Autor(es): dc.creator | Rosa, Suélia de Siqueira Rodrigues Fleury | - |
Data de aceite: dc.date.accessioned | 2024-10-23T15:12:17Z | - |
Data de disponibilização: dc.date.available | 2024-10-23T15:12:17Z | - |
Data de envio: dc.date.issued | 2020-05-19 | - |
Data de envio: dc.date.issued | 2020-05-19 | - |
Data de envio: dc.date.issued | 2018-06 | - |
Fonte completa do material: dc.identifier | https://repositorio.unb.br/handle/10482/37801 | - |
Fonte completa do material: dc.identifier | https://doi.org/10.1590/2446-4740.07517 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/877130 | - |
Descrição: dc.description | Introduction Many studies have been carried out on the main causes of hepatocellular carcinoma (HCC) to identify suitable diagnosis methods and treatments to combat the disease. However, high equipment costs and the lack of hepatic-ablation technologies manufactured in Brazil encourage the design and implementation of a solution based on normative principles. Methods The analysis and description of equipment features were the first steps in defining the design requirements and constraints. Equipment functionalities were evaluated with three assays set by NBR-IEC 60601-2-2. Results The assays of output control adjustment accuracy, output control adjustment monotonicity, and signal quality evaluation using the crest factor (CF) for the equipment showed thresholds superior to the aforementioned standard. Conclusion State-of-the-art studies have contributed the equipment construction. The construction process was validated by assays to ensure the equipment functionality with raw materials at acceptable costs. The test results showed the superiority of the equipment in relation to the assays proposed by the standard NBR-IEC 60601-2-2. However, to convert the prototype into a commercial product, other analyses are necessary. | - |
Descrição: dc.description | Faculdade UnB Gama (FGA) | - |
Formato: dc.format | application/pdf | - |
Publicador: dc.publisher | Sociedade Brasileira de Engenharia Biomédica | - |
Direitos: dc.rights | Acesso Aberto | - |
Direitos: dc.rights | (CC BY) - This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. | - |
Palavras-chave: dc.subject | Hospitais - mobiliário e equipamento | - |
Palavras-chave: dc.subject | Tratamento cirúrgico | - |
Palavras-chave: dc.subject | Carcinoma hepatocelular | - |
Título: dc.title | Development of radiofrequency ablation device for surgical hepatocellular carcinoma treatment in agreement with Brazilian standards | - |
Tipo de arquivo: dc.type | livro digital | - |
Aparece nas coleções: | Repositório Institucional – UNB |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: