Validação da ultrassonografia para a avaliação da gordura abdominal visceral em obesos clinicamente graves

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorGouvêa, Heloisa Rodrigues de-
Autor(es): dc.creatorFaria, Silvia Leite Campos Martins-
Autor(es): dc.creatorFaria, Orlando Pereira-
Autor(es): dc.creatorCardeal, Mariane de Almeida-
Autor(es): dc.creatorBezerra, Alexandre Sérgio de Araújo-
Autor(es): dc.creatorIto, Marina Kiyomi-
Data de aceite: dc.date.accessioned2024-10-23T15:08:37Z-
Data de disponibilização: dc.date.available2024-10-23T15:08:37Z-
Data de envio: dc.date.issued2017-12-07-
Data de envio: dc.date.issued2017-12-07-
Data de envio: dc.date.issued2013-
Fonte completa do material: dc.identifierhttp://repositorio.unb.br/handle/10482/28786-
Fonte completa do material: dc.identifierhttps://dx.doi.org/10.1590/S0102-67202013000600010-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/875478-
Descrição: dc.descriptionRACIONAL: A tomografia computadorizada é o padrão-ouro para a medida da gordura abdominal visceral. No entanto é dispendiosa e envolve submeter os doentes à radiação ionizante. OBJETIVO: Validar o método ultrassonográfico para avaliação da gordura abdominal visceral em obesos clinicamente graves de ambos os sexos. MÉTODOS: A amostra incluiu adultos com obesidade clinicamente grave que apresentavam índice de massa corporal de 40kg/m² ou entre 35kg/m² e 40kg/m² com comorbidades associadas. Os exames realizados para medição da espessura da gordura visceral foram: ultrassonografia e de tomografia computadorizada. Foram realizados dois exames para avaliação da reprodutibilidade interobservador em uma subamostra de pacientes. O estudo ultrassonográfico foi validado comparando-o aos resultados do exame tomográfico. RESULTADOS: Participaram do estudo 13 pacientes, sendo 61,54% mulheres com IMC médio de 38,82kg/m². A validação foi feita pelo coeficiente de correlação de Pearson resultando ser igual a 0,94 (p = 0,0005). Evidenciou-se correlação positiva e forte entre as duas medidas. Quanto aos resultados da reprodutibilidade, o coeficiente de correlação intraclasse interobservador foi igual a 0,822 com intervalo de confiança de 95% (-0,076 a 0,980), o que revela boa concordância interobservador. A diferença média entre os dois observadores na ultrassonografia foi igual a 0,10 ± 1,51 (p = 0,8898), não significativa e sem viés significativo interobservador. CONCLUSÃO: Foi efetiva a validação do exame ultrassonográfico como substituição ao tomográfico para avaliar a gordura abdominal visceral entre obesos clinicamente graves. A medida ultrassonográfica independe do examinador.-
Descrição: dc.descriptionBACKGROUND: Computerized tomography is the gold-standard for measurement of abdominal visceral fat. However, it is costly and involves submitting patients to ionizing radiation. AIM: To validate the use of ultrasonography in assessing abdominal visceral fat among clinically serious obese patients of both genders. METHODS: The sample included adult patients with clinically serious obesity with body mass index of 40kg/m2 or from 35kg/m2 to 40kg/m2 with co-morbidities. Abdominal visceral fat thickness was measured using ultrasound and tomography. Two ultrasonographic exams were conducted to assess the interobserver reproducibility among a patient subsample. Validation was done by comparing these results with the tomographic findings. RESULTS: The study included 13 patients (61.54% female) with an average BMI of 38.82 kg/m2. In terms of validation, the result obtained from applying the Pearson correlation coefficient was equal to 0.94 (p = 0.0005), showing a strong positive correlation between the two measurements. As for the results for reproducibility, the interobserver was equal to 0.822, with a confidence interval of 95% (-0.076 to 0.980), revealing good interobserver agreement. The average difference between the two ultrasound interobserver examination was equal to 0.10 ± 1.51 (p=0.8898) and so not significant. Interobserver bias was also not significant. CONCLUSION: The validation of ultrasonographic examination to replace tomographic method in assessing abdominal visceral fat among clinically serious obese patients was effective. The ultrasound measurement is independent of the examiner.-
Formato: dc.formatapplication/pdf-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Idioma: dc.languageen-
Publicador: dc.publisherColégio Brasileiro de Cirurgia Digestiva-
Direitos: dc.rightsAcesso Aberto-
Direitos: dc.rightsABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo) - (CC BY-NC) -Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons. Fonte: https://www.scielo.br/scielo.php?script=sci_arttext&pid=S0102-67202013000600010&lng=pt&tlng=pt. Acesso em: 24 ago. 2020.-
Palavras-chave: dc.subjectUltrassonografia-
Palavras-chave: dc.subjectGordura visceral-
Palavras-chave: dc.subjectObesidade-
Palavras-chave: dc.subjectCirurgia bariátrica-
Palavras-chave: dc.subjectObesidade - cirurgia-
Título: dc.titleValidação da ultrassonografia para a avaliação da gordura abdominal visceral em obesos clinicamente graves-
Título: dc.titleValidation of ultrasound examination for assessment of the abdominal visceral fat in clinically serious obese patient-
Tipo de arquivo: dc.typelivro digital-