Confiabilidade paralela do teste de 10 RM em máquina e elástico

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorMartins, Wagner Rodrigues-
Autor(es): dc.creatorFernandes, Jefferson Dias-
Data de aceite: dc.date.accessioned2024-10-23T15:03:16Z-
Data de disponibilização: dc.date.available2024-10-23T15:03:16Z-
Data de envio: dc.date.issued2018-12-17-
Data de envio: dc.date.issued2018-12-17-
Data de envio: dc.date.issued2018-12-17-
Data de envio: dc.date.issued2018-03-07-
Fonte completa do material: dc.identifierhttp://repositorio.unb.br/handle/10482/33211-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/873092-
Descrição: dc.descriptionDissertação (mestrado)—Universidade de Brasília, Faculdade de Ceilândia, Programa de Pós-Graduação em Ciências da Reabilitação, 2018.-
Descrição: dc.descriptionO Treinamento Resistido pode utilizar-se de pesos livres, máquinas, bandas elásticas ou outros dispositivos. O objetivo deste estudo é avaliar a confiabilidade paralela do teste de 10 Repetições Máximas (10RM) em máquinas de peso e resistência elástica nos membros superiores e membros inferiores. Trata-se de um estudo de confiabilidade paralela, onde participaram 23 jovens saudáveis, ambos os gêneros, considerados sedentários. As avaliações do teste de 10RM foram realizada nos seguintes exercícios supino vertical e cadeira extensora, quatro momentos, duas em cada ferramenta de resistência. Avaliação. Antes dos testes cada participante realizou uma sessão de familiarização em cada exercício, com uma resistência submáxima percebida pelo participante como sendo “um pouco fácil”, que serviu também como forma de aquecimento. Dentre os resultados encontrados, o Coeficiente de Correlação Intra-classe (CCI), que representa a confiabilidade relativa, foi classificado como alto, com índices de 0,84 e 0,92 para membros superiores, e 0,78 e 0,88 para inferiores. A Representação Gráfica de Bland-Altman mostrou erro sistemático de 5,2 Kg e 6,7 Kg; a relativa de erro padrão da medida (EPM%) de 9,5% e 13,6% para membro superior. Para membro inferior o erro sistemático foram 1,8 Kg e 2,1 Kg e 10,6% e 10,7% para EPM%. Em ambos os exercícios obtivemos erro dentro do limite aceitável, apresentanto uma boa confiabilidade paralela entre as ferramentas de resistência. Conclui-se que resistência elástica, através do teste de multiplas repetições, apresenta uma alta confiabilidade relativa, como também evidencia uma confiabilidade absoluta com margem de erro aceitável, e mostra-se uma ferramenta e confiável na avaliação, prescrição e controle de carga, aplicável na prática clínica e em programas de treinamento resistido de jovens adultos, destreinados.-
Descrição: dc.descriptionResistance Training can be used with free weights, machines, elastic bands or other devices. The objective of this study is to evaluate the parallel reliability of the 10 Maximum Repetitions (10RM) test in machines of weight and elastic resistance in the upper limbs and lower limbs. This is a parallel reliability study, involving 23 healthy youngsters, both genders, considered to be sedentary. The 10RM test evaluations were performed in the following vertical bench press and extensor chair exercises, four moments, two in each resistance tool. Evaluation. Before the tests each participant performed a familiarization session in each exercise, with a submaximal resistance perceived by the participant as being "a little easy", which also served as a form of warm-up. Among the results found, the Intraclass Correlation Coefficient (ICC), which represents relative reliability, was classified as high, with indexes of 0.84 and 0.92 for upper limbs, and 0.78 and 0.88 for lower. The Bland-Altman Graphical Representation showed a systematic error of 5.2 kg and 6.7 kg; the relative standard error of measurement (EPM%) of 9.5% and 13.6% for upper limb. For lower limb the systematic error was 1.8 kg and 2.1 kg and 10.6% and 10.7% for EPM%. In both exercises we obtained error within the acceptable limit, presenting a good parallel reliability between the resistance tools. It is concluded that elastic resistance, through the test of multiple repetitions, presents a high relative reliability, but also evidences an absolute reliability with acceptable margin of error, and it is a tool and reliable in the evaluation, prescription and control of load, applicable in clinical practice and in untrained young adult resistance training programs.-
Descrição: dc.descriptionFaculdade UnB Ceilândia (FCE)-
Descrição: dc.descriptionFaculdade UnB Ceilândia (FCE)-
Descrição: dc.descriptionPrograma de Pós-Graduação em Ciências da Reabilitação-
Descrição: dc.descriptionPrograma de Pós-Graduação em Ciências da Reabilitação-
Formato: dc.formatapplication/pdf-
Direitos: dc.rightsAcesso Aberto-
Palavras-chave: dc.subjectExercício resistido-
Palavras-chave: dc.subjectTreinamento de resistência-
Palavras-chave: dc.subjectTreinamento com peso-
Palavras-chave: dc.subjectMáquinas de peso-
Palavras-chave: dc.subjectResistência elástica - exercícios-
Título: dc.titleConfiabilidade paralela do teste de 10 RM em máquina e elástico-
Tipo de arquivo: dc.typelivro digital-
Aparece nas coleções:Repositório Institucional – UNB

Não existem arquivos associados a este item.