Distribuição de tensões em mini-implantes ortodônticos

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.creatorDobranszki, A.-
Autor(es): dc.creatorLevy Neto, F.-
Autor(es): dc.creatorDobranszki, N.C.-
Autor(es): dc.creatorVuolo, J.H.-
Autor(es): dc.creatorLaboissière Jr., M.A.-
Data de aceite: dc.date.accessioned2024-07-24T13:39:42Z-
Data de disponibilização: dc.date.available2024-07-24T13:39:42Z-
Data de envio: dc.date.issued2017-12-07-
Data de envio: dc.date.issued2017-12-07-
Data de envio: dc.date.issued2010-
Fonte completa do material: dc.identifierhttp://repositorio.unb.br/handle/10482/27874-
Fonte completa do material: dc.identifierhttps://dx.doi.org/10.1590/S1517-70762010000300003-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/856220-
Descrição: dc.descriptionO objetivo deste trabalho foi avaliar a distribuição de tensões na resina em contato com os filetes de roscas de mini-implantes cilíndricos e cônicos, submetidos à carga lateral e torção de inserção. Um modelo fotoelástico foi confeccionado com gelatina transparente, para simular o osso alveolar. O modelo foi observado com um polariscópio plano e fotografado antes e após a ativação dos mini-implantes com força lateral e de inserção. A aplicação de cargas laterais provocou momentos fletores nos mini-implantes, aparecimento de franjas isocromáticas ao longo dos filetes do corpo dos mini-implantes e no ápice. Quando foi aplicado o torque de inserção, verificou-se a concentração de tensões próxima ao ápice. Concluiu-se que: (1) o mini-implante cilíndrico apresentou maior concentração de tensões no ápice, e (2) o mini-implante cônico apresentou maior concentração de tensões nos filetes de rosca apicais.-
Descrição: dc.descriptionThe objective of this study was to evaluate the stress distribution in the resin in contact with the spirals of cylindrical and conical mini-implants, when submitted to lateral load and insertion torsion. A photoelastic model was fabricated using transparent gelatin to simulate the alveolar bone. The model was observed with a plane polariscope and photographically recorded before and after activation of the two screws with a lateral force and torsion. The lateral force application caused bending moments on both mini-implants, with the uprising of fringes or isochromatics, characteristics of stresses, along the threads of the mini-implants and in the apex. When the torsion was exerted in the mini-implants, a great concentration of stress upraised close to the apex. The conclusion was that, comparing conical with cylindrical mini-implants under lateral load, the stresses were similar on the traction sides. The differences appear (1) on the apex, where the cylindrical mini-implant showed a greater concentration of stress, and (2) along the spirals, in the compression side, where the conical mini-implant showed a greater concentration of stress. The greater part of the stress produced by both mini-implants, after torsion load in insertion, were concentrated on the apex. With the cylindrical mini-implant, the greater concentration of tension was close to the apex, while with the conical one, the stresses were distributed along a greater amount of apical threads.-
Descrição: dc.descriptionEm processamento-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Publicador: dc.publisherRede Latino-Americana de Materiais-
Direitos: dc.rightsAcesso Aberto-
Palavras-chave: dc.subjectdistribuição de tensões-
Palavras-chave: dc.subjectfotoelasticidade-
Palavras-chave: dc.subjectmini-implantes-
Palavras-chave: dc.subjectancoragem absoluta-
Palavras-chave: dc.subjectstress distribution-
Palavras-chave: dc.subjectphotoelasticity-
Palavras-chave: dc.subjectmini-implants-
Palavras-chave: dc.subjectabsolute anchorage-
Título: dc.titleDistribuição de tensões em mini-implantes ortodônticos-
Título: dc.titleStress distribution in orthodontic mini-implants-
Tipo de arquivo: dc.typeArtigo-
Aparece nas coleções:Repositório Institucional – UNB (old)

Não existem arquivos associados a este item.