Avaliação da integração óptica da fluorescência entre dentes naturais e restaurações em cerâmica pura

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorCavalcante, Larissa Maria Assad-
Autor(es): dc.contributorhttp://lattes.cnpq.br/5317492400019461-
Autor(es): dc.contributorGallito, Marco Antonio-
Autor(es): dc.contributorhttp://lattes.cnpq.br/1415378853454901-
Autor(es): dc.contributorBrigagão, Vinicius Carvalho-
Autor(es): dc.contributorResende, Tayane Holz-
Autor(es): dc.contributorhttp://lattes.cnpq.br/4695251234772830-
Autor(es): dc.creatorRibeiro, Isabela Lopes Eustáquio-
Data de aceite: dc.date.accessioned2024-07-22T13:55:51Z-
Data de disponibilização: dc.date.available2024-07-22T13:55:51Z-
Data de envio: dc.date.issued2024-07-12-
Data de envio: dc.date.issued2024-07-12-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/33273-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/823189-
Descrição: dc.descriptionO objetivo deste estudo foi avaliar a integração óptica da fluorescência entre dentes naturais e hemi-facetas confeccionadas com 3 tipos de materiais cerâmicos, submetidos ou não à aplicação de um glaze fluorescente. Material e método: Dentre os 6 elementos coletados de diferentes indivíduos e armazenados em solução com timol, 1 (um), que atendeu aos critérios de inclusão predefinidos foi selecionado para que sobre ele fossem confeccionadas hemi-facetas com espessura de 0,5mm. Inicialmente foi feita a mensuração da cor utilizando o espectrofotômetro (VITA EasyShade Compact) e também com a escala de cor VITA Clássica. As medidas da cor foram nos terços cervical, médio e incisal da coroa. Três tipos de cerâmica foram avaliadas: feldspática (Trilux forte CAD – VITA), dissilicato de lítio (E-max CAD MT – Ivoclar Vivadent) e leucita (Empress CAD Multi - Ivoclar Vivadent). As hemi-facetas foram confeccionadas por um laboratório experiente de acordo com a cor selecionada. Para cada material quatro restaurações foram confeccionadas sendo duas submetidas à aplicação do glaze fluorescente (GF) e duas à aplicação do glaze convencional (GC). As hemi-facetas foram fixadas no dente preparado com try-in cor transparente (Variolink Esthetic try-in – Ivoclar Vivadent) , o dente foi fotografado sob condições de luz padronizadas e fluorescente. Na sequência as imagens obtidas foram apresentadas em forma de questionário online para 9 técnicos em prótese e 9 cirurgiões-dentistas especialistas. Todos os avaliadores eleitos foram submetidos ao Teste de Ishihara, para verificação da acuidade visual. Cada avaliador deveria pontuar as fotos de acordo com o Índice de Integração Óptica (IIO). Foram apresentadas um total 48 fotos para cada avaliador. A pontuação foi definida em escores como a "visibilidade" da restauração em comparação com o dente natural (metade hígida) em uma escala de 1 a 4. Sendo o escore 1 = pior integração óptica, sendo a restauração facilmente diferenciada do dente natural e o escore 4 = melhor integração óptica, sendo a restauração imperceptível. Os escores foram atribuídos de acordo com 4 condições de luz direta, indireta 10cm, indireta 15cm e fluorescente. Os dados foram submetidos ao teste de Qui-quadrado. Todos os testes estatísticos foram executados com um alfa predefinido de 0,05. Resultados: Diferenças significativas foram observadas entre a opinião dos avaliadores (p<0,001). Também foi observada diferença estatística significativa no IIO das diferentes cerâmicas quando aplicado GF em ordem decrescente, e-max CAD, Trilux forte e Empress CAD. Conclusões: O uso de glaze fluorescente exibe melhor integração óptica para restaurações em dissilicato de lítio sob luz UV. Restaurações em cerâmica feldspática e leucita não necessitam de glaze fluorescente para uma melhor integração óptica com o elemento dental. Sugere-se ainda uma comunicação aprimorada e alinhamento de expectativas entre especialista e TPD-
Descrição: dc.descriptionThe objective of this study was to evaluate the optical integration of fluorescence between natural teeth and hemi-facets made with 3 types of ceramic materials, whether or not they were subjected to the application of a fluorescent enamel. Material and method: Among the 6 elements found from different individuals and stored in a solution with thymol, 1 (one) that met the predefined inclusion criteria were selected so that hemi-facets with a thickness of 0.5 mm could be made on it. Initially, color was measured using the spectrophotometer (VITA EasyShade Compact) and also with the VITA Classic color scale. Color measurements were in the cervical, middle and incisal thirds of the crown. Three types of ceramic were evaluated: feldspar (Trilux forte CAD – VITA), lithium disilicate (E-max CAD MT – Ivoclar Vivadent) and leucite (Empress CAD Multi - Ivoclar Vivadent). The hemi-facets were made by an experimental laboratory according to the selected color. For each material, four restorations were made, two of which were subjected to the application of fluorescent enamel (GF) and two to the application of conventional enamel (GC). The hemi-facets were inserted into the tooth prepared with transparent try-in color (Variolink Esthetic try-in – Ivoclar Vivadent), the tooth was photographed under standardized and fluorescent light conditions. Afterwards, the images obtained were presented in the form of an online questionnaire to 9 prosthetic technicians and 9 specialist dental surgeons. All elected evaluators were subjected to the Ishihara Test to verify visual acuity. Each evaluator had to score the photos according to the Optical Integration Index (IIO). A total of 48 photos were presented to each evaluator. The score was defined in scores as the "visibility" of the restoration compared to the natural tooth (healthy half) on a scale of 1 to 4. Score 1 = worst optical integration, with the restoration being easily differentiated from the natural tooth and the score 4 = better optical integration, with the restoration being imperceptible. The scores were assigned according to 4 conditions of direct light, indirect 10cm, indirect 15cm and fluorescent. The data were subjected to the Chisquare test. All statistical tests were performed with a predefined alpha of 0.05. Results: Significant differences were observed between the evaluators' opinions (p<0.001). A significant statistical difference was also observed in the IIO of the different ceramics when GF was applied in descending order, e-max CAD, Trilux forte and Empress CAD. Conclusions: The use of fluorescent glaze exhibits better optical integration for lithium disilicate restorations under UV light. Feldspathic and leucite ceramic restorations do not require fluorescent glaze for better optical integration with the dental element. It is also suggested improved communication and alignment of expectations between specialist and TPD-
Descrição: dc.description59 f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectFluorescência-
Palavras-chave: dc.subjectCerâmica-
Palavras-chave: dc.subjectFeldspática-
Palavras-chave: dc.subjectLeucita-
Palavras-chave: dc.subjectDissilicato de lítio-
Palavras-chave: dc.subjectMetal-free-
Palavras-chave: dc.subjectFacetas dentárias-
Palavras-chave: dc.subjectCerâmica-
Palavras-chave: dc.subjectFluorescência-
Palavras-chave: dc.subjectDente-
Palavras-chave: dc.subjectFluorescence-
Palavras-chave: dc.subjectCeramic-
Palavras-chave: dc.subjectFeldspathic-
Palavras-chave: dc.subjectLeucite-
Palavras-chave: dc.subjectLithium disilicate-
Palavras-chave: dc.subjectMetal-free-
Título: dc.titleAvaliação da integração óptica da fluorescência entre dentes naturais e restaurações em cerâmica pura-
Título: dc.titleEvaluation of optical integration of fluorescence between natural teeth and pure ceramic restorations-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.