Estudo da cobertura do sinal de 14 GHz em ambientes fechados

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorMatos, Leni Joaquim de-
Autor(es): dc.contributorFerreira, Tadeu Nagashima-
Autor(es): dc.contributorMagri, Vanessa Przyblski Ribeiro-
Autor(es): dc.contributorCastellanos, Pedro Vladimir Gonzalez-
Autor(es): dc.creatorCosenza, Vivian Barreiros-
Data de aceite: dc.date.accessioned2024-07-11T18:46:42Z-
Data de disponibilização: dc.date.available2024-07-11T18:46:42Z-
Data de envio: dc.date.issued2018-01-08-
Data de envio: dc.date.issued2018-01-08-
Data de envio: dc.date.issued2018-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/5432-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/777376-
Descrição: dc.descriptionEste trabalho trata do estudo de cobertura do sinal de faixa estreita na frequência de 14 GHz em ambientes fechados, como corredores e salas. As frequências no espectro das ondas milimétricas vêm sendo estudadas para utilização na tecnologia dos sistemas de quinta geração da telefonia celular e, por isso, não apresentam ainda grande quantidade de dados referentes aos modelos mais adequados. O objetivo do trabalho é avaliar o comportamento desse sinal e identificar o modelo de predição mais adequado. Foram realizadas medições em dois corredores com características distintas e em um hall em situação de visada direta, e em duas salas diferentes em ambiente sem visada, para obtenção de dados em diversas situações. Foram utilizados os modelos FI (Floating-Intercept), CI (Closed-In) e o modelo da recomendação da ITU-R P.1238-9. Os resultados obtidos mostraram que o modelo mais próximo dos valores medidos foi o FI, apesar de seus parâmetros apresentaram grande variação entre diferentes ambientes. Também foi possível estimar o valor do expoente de perdas (n) do modelo CI como 1,6 para corredores, 3,1 para ambientes mais amplos e 3,7 para salas cujos ambientes não sejam de visada direta. Foi possível estimar o valor do coeficiente N do modelo da recomendação da ITU como próximo de 16 para corredores, e entre 14 e 15 para salas sem visada direta das antenas. Percebeu-se também que a presença de uma parede de concreto entre as antenas causou uma queda de aproximadamente 20 dB de potência. Verificou-se que os resultados encontrados para corredores estavam de acordo com os obtidos em outros trabalhos de pesquisa nessa área e que seriam necessárias mais medições para confirmação dos parâmetros adequados da recomendação da ITU para ambientes sem visada direta na frequência de 14 GHz-
Descrição: dc.descriptionThis work deals with the study of the 14 GHz narrowband signal coverage in indoor environments, such as corridors and rooms. The milimeter-wave frequency spectrum have been studied to be used in the fifth generation technology of mobile communications systems, and that is why they does not have yet, a large amount of data regarding the most suitable models. The objective of this paper is to evaluate the behavior of this signal and to identify the most appropriate propagation model. There were performed measurements in five distinct environments, two corridors, a hall and two rooms, to obtain data from various situations. The first three cases were in line-of-sight and the other two were in a non-line-of-sight situation. The propagation models used were the FI (Floating-Intercept), CI (Closed-In) and the recommendation ITU-R P.1238-9. The results shown that, the best fit model was the FI, although its parameters had a great variation among the different cases that have been studied. It was possible to evaluate the path loss exponent (n) of the CI model as approximately 1.6 for corridors, 3.1 for broader rooms and 3.7 for non-line-of-sight rooms. Besides that, was possible estimate the value of N coefficient of the ITU model as close to 16 for corridors and between 14 and 15 for rooms without line-of-sight. It was noticed as well, that the concrete wall present between the antennas introduced a 20 dB loss in the received power. It was verified that the results found for corridors were in agreement with those obtained in others research studies in this area and further measurements campaigns would be necessary to confirm the parameters of the ITU model for the non-line-of-sight environments in the 14 GHz frequency-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Publicador: dc.publisherUniversidade Federal Fluminense-
Publicador: dc.publisherNiterói, RJ-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectOndas milimétricas-
Palavras-chave: dc.subjectModelos de predição-
Palavras-chave: dc.subjectFrequência de 14 GHz-
Palavras-chave: dc.subjectPropagação de sinal-
Palavras-chave: dc.subjectTelefonia celular-
Palavras-chave: dc.subjectOndas ultra curtas-
Palavras-chave: dc.subject14 GHz frequency-
Palavras-chave: dc.subjectMilimeter-wave frequency wave-
Palavras-chave: dc.subjectPropagation models-
Título: dc.titleEstudo da cobertura do sinal de 14 GHz em ambientes fechados-
Tipo de arquivo: dc.typeTrabalho de conclusão de curso-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.