Determinação voltamétrica de chumbo em amostras de creme capilar tonalizante por meio de eletrodos compósitos

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorSemaan, Felipe Silva-
Autor(es): dc.contributorRamirez, Ninoska Isabel Bojorge-
Autor(es): dc.contributorLepri, Fabio Grandis-
Autor(es): dc.creatorFernandes, Julia Oliveira-
Data de aceite: dc.date.accessioned2024-07-11T18:45:45Z-
Data de disponibilização: dc.date.available2024-07-11T18:45:45Z-
Data de envio: dc.date.issued2016-08-17-
Data de envio: dc.date.issued2016-08-17-
Data de envio: dc.date.issued2016-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/2133-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/777042-
Descrição: dc.descriptionOs metais tóxicos são muito nocivos à saúde humana, pois alteram atividades bioquímicas no organismo provocando diversas doenças. Neste contexto, detectá-los de forma fácil, rápida, barata e reprodutível nos diversos produtos utilizados pelo homem é muito importante. Alguns cosméticos contêm quantidades consideráveis de metais tóxicos e essas precisam ser determinadas e monitoradas para que a sua absorção pelo organismo possa ser controlada. No presente trabalho determinou-se chumbo (um metal tóxico) em amostras reais de um creme capilar tonalizante, o Grecin 2000®, por meio da voltametria de onda quadrada (SWV). A análise voltamétrica pode ser dividida em três etapas: um pré-tratamento aplicando um potencial de -1,4 V durante 120 segundos, SWV de -1,5 V a +0,1 V em condições otimizadas (frequência 25 Hz, amplitude 50 mV e degrau 10 mV) e um pós-tratamento de +0,3 V durante 60 segundos, para limpeza. O eletrodo de trabalho utilizado na determinação consiste em um eletrodo compósito de grafite-epóxi (65% m/m) modificado por um filme de bismuto formado in situ, um eletrodo de referência de Ag|AgCl e um contra-eletrodo de fio fino de prata. Obteve-se uma média de (0,505 ± 0,025) % de acetato de chumbo (%m/m) na amostra de Grecin® com uma média de recuperação de (98,75 ± 6,58)%. Os limites de detecção, quantificação e região linear foram respectivamente 0,07 µmol L-1, 0,21 µmol L-1 e 0,98 – 1,92 µmol L-1 para o Pb, 0,36 µmol L-1, 1,09 µmol L-1 e 2,99 – 14,5 µmol L-1 para o Zn e 0,05 µmol L-1, 0,15 µmol L-1 e 0,50 – 2,47 µmol L-1 para o Cd. Como procedimento de comparação realizou-se a espectrometria de absorção atômica em chama (F AAS). Os resultados obtidos foram satisfatórios e compatíveis com a porcentagem divulgada pelo fabricante e abaixo da permitida pela ANVISA, sendo também compatíveis ao método de comparação-
Descrição: dc.descriptionToxic metals are very harmful to human health since they can change biochemical activity in the body causing various diseases. In this context, their easy and fast detection, in a cheap and reproducible way in different products used by humans is very important. Some cosmetics contain considerable amounts of toxic metals conducting this to the need to determining and monitoring allowing in such sense human exposure. In this study lead was determined (a toxic metal) in real samples of a hair cream tint, the Grecin 2000®, by square wave voltammetry (SWV). Voltammetric analysis can be divided into three steps: a pretreatment by applying a potential of -1.4 V for 120 seconds, SWV -1.5 V to +0.1 V under optimized conditions (frequency 25 Hz, amplitude of 50 mV and the step 10 mV), and a post-treatment of +0.3 V for 60 seconds for cleaning. The working electrode consisted of a graphite-epoxy composite electrode (65% m/m) modified by a film of bismuth formed in situ, the reference electrode was Ag|AgCl and a thin silver wire counter electrode. It was obtained as a weighted average (0.505 ± 0.025)% lead acetate (% m/m) in the sample Grecin® with an average recovery (98.75 ± 6.58)%. The limits of detection, quantification and linear region were respectively 0.07 µmol L-1, 0.21 µmol L-1and from 0.98 to 1.92 µmol L-1for Pb, 0.36 µmol L-1, 1.09 µmol L-1 and from 2.99 to 14.5 µmol L-1 for Zn and 0.05 µmol L-1, 0.15 µmol L-1 and from 0.50 to 2.47 µmol L-1 for Cd. As a comparison procedure was held on Atomic Absorption Spectrometry in Flame (F AAS).Results found were satisfactory and consistent with the percentage reported by the manufacturer and below the permitted by ANVISA, being also compatible to those found by a comparison method-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectEletroquímica-
Palavras-chave: dc.subjectEletrodos compósitos-
Palavras-chave: dc.subjectMetais-
Palavras-chave: dc.subjectDetecção de chumbo-
Palavras-chave: dc.subjectCosméticos-
Palavras-chave: dc.subjectVoltametria-
Palavras-chave: dc.subjectEletroquímica-
Palavras-chave: dc.subjectEletrodo compósito-
Palavras-chave: dc.subjectCosmético-
Palavras-chave: dc.subjectVoltametria-
Palavras-chave: dc.subjectChumbo-
Palavras-chave: dc.subjectElectrochemistry-
Palavras-chave: dc.subjectComposite electrodes-
Palavras-chave: dc.subjectMetals-
Palavras-chave: dc.subjectLead determination-
Palavras-chave: dc.subjectCosmetics-
Palavras-chave: dc.subjectVoltammetry-
Título: dc.titleDeterminação voltamétrica de chumbo em amostras de creme capilar tonalizante por meio de eletrodos compósitos-
Tipo de arquivo: dc.typeTrabalho de conclusão de curso-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.