Estudo comparativo entre sistema tradicional de chuveiros automáticos e sistema water mist para combate a incêndio em edificações de patrimônio histórico e cultural estudo de caso: Biblioteca Nacional (RJ)

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorHall, James-
Autor(es): dc.contributorCanto, Bárbara Letícia-
Autor(es): dc.contributorMarques, Débora Candeias-
Autor(es): dc.contributorZotes, Luis Perez-
Autor(es): dc.creatorCanto, Bruna-
Data de aceite: dc.date.accessioned2024-07-11T18:40:39Z-
Data de disponibilização: dc.date.available2024-07-11T18:40:39Z-
Data de envio: dc.date.issued2024-07-09-
Data de envio: dc.date.issued2024-07-09-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/33120-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/775272-
Descrição: dc.descriptionOs grandes incêndios ocorridos nas últimas décadas despertaram a atenção para a segurança contra incêndio e pânico existente no país e a legislação que vigora. A escassez hídrica que o mundo tem enfrentado e todas as projeções feitas levam a uma incessante busca por inovações tecnológicas e de gestão sustentável para atingirmos o equilíbrio entre a demanda e a disponibilidade de água para futuras gerações. Devido a perdas inestimáveis ao patrimônio histórico e cultural, tanto causadas pelo fogo quanto pela água em seu combate, surge o interesse em estudar um sistema, desenvolvido e aplicado no exterior a algum tempo, que utilize menos água e cause menos danos aos ativos, Water Mist. O estudo comparativo entre o sistema tradicional de chuveiros automáticos e o sistema Water Mist aplicados na Biblioteca Nacional (RJ), mostrou a superioridade tecnológica do sistema Water Mist, e a importância do seu desenvolvimento e inclusão nas normas e legislações brasileiras-
Descrição: dc.descriptionThe major fires that have occurred in the recent decades have drawn attention to the country's existing fire safety codes and legislation. The world has faced a water scarcity that lead to an unceasing search for technological innovations and sustainable development to reach the balance between water demand and availability for future generations. Due to the priceless losses to historical and cultural heritage caused by fires and water used in fire fighting, the interest in studying the water mist system, developed and applied abroad for some time, that uses less water and causes less damage to assets has risen. This theses studied the design of both sprinkler and Water Mist systems for the National Library (Rio de Janeiro). It presents the technological superiority of the Water Mist system and showed how important its development and inclusion in the Brazilian fire safety codes and law are-
Descrição: dc.description92 f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectCombate a incêndio-
Palavras-chave: dc.subjectChuveiro automático-
Palavras-chave: dc.subjectBiblioteca Nacional (Brasil)-
Palavras-chave: dc.subjectIncêndios e prevenção de incêndio-
Palavras-chave: dc.subjectIncêndios - Extinção-
Palavras-chave: dc.subjectFire fighting-
Palavras-chave: dc.subjectSprinkler-
Palavras-chave: dc.subjectWater mist-
Título: dc.titleEstudo comparativo entre sistema tradicional de chuveiros automáticos e sistema water mist para combate a incêndio em edificações de patrimônio histórico e cultural estudo de caso: Biblioteca Nacional (RJ)-
Tipo de arquivo: dc.typeTrabalho de conclusão de curso-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.