Eficiência de preparo em função do tempo de utilização, de um novo instrumento com liga maxwire

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorVianna, Gustavo André de Deus Carneiro-
Autor(es): dc.contributorOliveira, Henrique Eduardo-
Autor(es): dc.contributorSilva, Emmanuel João Nogueira Leal da-
Autor(es): dc.contributorhttp://lattes.cnpq.br/8867183053272365-
Autor(es): dc.contributorhttp://lattes.cnpq.br/8005271079083909-
Autor(es): dc.creatorCarvalho, Marco Simões de-
Data de aceite: dc.date.accessioned2024-07-11T18:40:04Z-
Data de disponibilização: dc.date.available2024-07-11T18:40:04Z-
Data de envio: dc.date.issued2020-12-13-
Data de envio: dc.date.issued2020-12-13-
Data de envio: dc.date.issued2018-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/16335-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/775073-
Descrição: dc.descriptionO objetivo deste estudo foi verificar a potencial correlação entre o tempo de trabalho e a capacidade de formatação do novo instrumento XP-endo Shaper com liga MaxWire. A metodologia utilizada neste trabalho seguiu o seguinte protocolo: dez raízes mesiais de molares inferiores foram escaneadas em um microtomógrafo e preparadas até o seu comprimento de trabalho (CT) de acordo com as recomendações do fabricante utilizando 2mL de irrigação em cada entrada do instrumento. Depois disso, cada amostra foi submetida a um tempo extra de instrumentação ativa até o CT em 15, 30 e 45 segundos. Foram realizados escaneamentos pós-operatórios, após cada tempo extra acima estabelecido. Dessa forma, os conjuntos de imagens pré e pós operatórias registrados foram examinados a fim de avaliar em cada dente as porcentagens de raspas de dentina acumuladas, volume e área de superfície do canal instrumentado, áreas não tocadas e volume de dentina removido. Um modelo linear geral de medidas repetidas foi usado para comparar as diferenças tanto no aumento quanto na redução de parâmetros, a cada tempo operatório. Foi estipulado um erro alfa de 5%. Os resultados obtidos foram: a extensão do período de ativação da XP-endo Shaper no CT influencia drasticamente vários parâmetros, tais como: volume (P = 0.000) e área de superfície (P = 0.000) dos canais instrumentados, área de paredes não tocadas (P = 0.000) e volume de dentina removida (P = 0.000). O volume de raspas de dentina não foi influenciado pelo tempo de instrumentação ativa da XP-endo Shaper (P=0.343). Pode-se concluir que a extensão do tempo de utilização da XP-endo Shaper no CT resulta em um preparo do canal radicular mais abrangente, aumentando o volume do canal preparado e de dentina removida e diminuindo a porcentagem de paredes não tocadas-
Descrição: dc.descriptionThis study verified the potential correlation between working time and the shaping ability of the new XP-endo Shaper instrument. Ten mesial roots of mandibular molars were scanned in a micro-computed tomographic device and prepared up to the working length (WL) according to the manufacturer’s recommendation. Then, each specimen was subjected to an extra 15, 30 and 45 seconds of active instrumentation at the WL. Postoperative scans were performed after canal preparation at each time-point. Then, the registered pre- and postoperative datasets were examined to evaluate the percentages of accumulated hard-tissue debris, volume and surface area of the instrumented canal, surface area of non-instrumented canal areas and the volume of removed dentine. Repeated measures general linear model was used to compare the differences in either the increase or the reduction of the parameters among the time-points. Alpha-error was set at 5%. Extending the period of XP-endo Shaper active instrumentation at the WL highly influenced several parameters such as volume (P = 0.000) and surface area (P = 0.000) of the instrumented canal, surface area of non-instrumented canal areas (P = 0.000), and volume of removed dentin (P = 0.000). The volume of debris was not influenced by the period of XP-endo Shaper active instrumentation (P = 0.343). Extending activation time of the XP-endo Shaper instrument at the WL resulted in a significantly more comprehensive root canal preparation, enhancing the volume of root canal preparation and dentin removed, and diminishing the percentage of non-instrumented canal areas-
Descrição: dc.description48f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nc-nd/3.0/br/-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectRemoção de dentina-
Palavras-chave: dc.subjectRaspas de dentina-
Palavras-chave: dc.subjectMicro-CT-
Palavras-chave: dc.subjectÁrea de paredes não tocadas-
Palavras-chave: dc.subjectXP-endo Shaper-
Palavras-chave: dc.subjectPreparo do canal radicular-
Palavras-chave: dc.subjectDentina-
Palavras-chave: dc.subjectDentine removed-
Palavras-chave: dc.subjectHard-tissue debris-
Palavras-chave: dc.subjectNon-instrumented canal areas-
Título: dc.titleEficiência de preparo em função do tempo de utilização, de um novo instrumento com liga maxwire-
Título: dc.titleShaping efficiency as a function of time of a new heat-treated snake-shaped instrument-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.