Avaliação das modificações da superfície dos implantes após inserção: um estudo laboratorial

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorGouvêa, Cresus Vinicius Depes de-
Autor(es): dc.contributorGallito, Marco Antonio-
Autor(es): dc.contributorJorge, Mônica Zacharias-
Autor(es): dc.contributorhttp://lattes.cnpq.br/0280448138621492-
Autor(es): dc.contributorhttp://lattes.cnpq.br/9924799549240650-
Autor(es): dc.contributorhttp://lattes.cnpq.br/1415378853454901-
Autor(es): dc.contributorhttp://lattes.cnpq.br/6968191712615860-
Autor(es): dc.creatorSalim, Daniel de Mattos-
Data de aceite: dc.date.accessioned2024-07-11T18:39:19Z-
Data de disponibilização: dc.date.available2024-07-11T18:39:19Z-
Data de envio: dc.date.issued2020-10-21-
Data de envio: dc.date.issued2020-10-21-
Data de envio: dc.date.issued2016-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/15378-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/774800-
Descrição: dc.descriptionObjetivo: Avaliar a superfície dos implantes após a instalação em poliuretano (osso artificial) e possíveis implicações dos detritos de partículas destas superfícies. Metodologia: Quinze implantes comerciais, de superfícies, anodizada (5), duplo ataque ácido (5) e ataque ácido (5) foram instalados em blocos de osso artificial de poliuretano de densidade correspondente ao osso D1, D2 utilizando brocas próprias para inserção de implantes. Uma perfuração foi feita na linha da interface entre uma metade e outra do osso artificial com torque máximo de 45Ncm. As deformações macro e microscópicas dos implantes foram avaliadas antes e depois do ato da inserção, em Microscópio Eletrônico de Varredura (MEV). Os blocos de osso foram separados em duas metades pós-inserção e avaliados através de MEV e Espectroscopia de Energia Dispersiva (EDS). Resultados: O MEV mostrou danos na superfície dos implantes pós-inserção. Implantes anodizados demonstraram danos amplos; onde parte da camada de óxido foi removida nas cristas das roscas, expondo o material subjacente. Nos blocos de poliuretano onde os implantes anodizados foram instalados partículas de titânio de diferentes tamanhos foram encontradas. Conclusão: O presente estudo demonstrou danos na superfície pós- inserção de implantes anodizados em blocos de poliuretano, associados com partículas de titânio na interface. Implantes com tratamento de ataque ácido e duplo ataque ácido não apresentaram mundaças significativas-
Descrição: dc.descriptionObjective: To evaluate the effects on the surface of the implants after the artificial bone installation and possible implications of particles of debris from these surfaces. Methods: Fifteen commercial implants of surfaces, anodized (5), double acid-etched (5) and acid-etched (5) have been installed in polyurethane artificial bone block corresponding bone density D1, D2 using proper drills for inserting implants. A perforation was made in the line interface between a half and another of artificial bone with maximum torque 45Ncm. Macro and microscopic implants deformations were evaluated before and after the act of insertion in Scanning Electron Microscope (SEM). Bone blocks were separated into two halves post insertion and were evaluated by SEM and Energy Dispersive Spectroscopy (EDS). Results: SEM showed damage to the surface after insertion. Anodised implants demonstrated large damage, in which part of the oxide layer was removed from the crests of the threads, exposing the underlying material. In polyurethane blocks in which the anodized implants were installed titanium particles in different sizes were found. Conclusion: This study showed damage to the surface post insertion of anodized implants, and titanium particles were found in polyurethane bone blocks.-
Descrição: dc.description34 f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nc-nd/3.0/br/-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectImplantes dentários-
Palavras-chave: dc.subjectOsteólise-
Palavras-chave: dc.subjectCaracterizarão de superfície-
Palavras-chave: dc.subjectRugosidade superficial-
Palavras-chave: dc.subjectImplante dentário-
Palavras-chave: dc.subjectRugosidade (Superfície)-
Palavras-chave: dc.subjectDental implants-
Palavras-chave: dc.subjectOsteolysis-
Palavras-chave: dc.subjectSurface characterization-
Palavras-chave: dc.subjectSurface roughness-
Título: dc.titleAvaliação das modificações da superfície dos implantes após inserção: um estudo laboratorial-
Título: dc.titleEvaluation of implant surface modifications post-insertion: a laboratory study-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.