Avaliação da fidelidade dimensional na utilização da tomografia computadorizada de feixe cônico na mensuração da espessura gengival

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorSantos, Gustavo Oliveira dos-
Autor(es): dc.contributorAndreiuolo, Rafael Ferrone-
Autor(es): dc.contributorGallito, Marco Antônio-
Autor(es): dc.contributorhttp://lattes.cnpq.br/7810555175483977-
Autor(es): dc.contributorhttp://lattes.cnpq.br/6000040925083803-
Autor(es): dc.creatorMacedo, Anna Carolina Venâncio Britto de-
Data de aceite: dc.date.accessioned2024-07-11T18:33:51Z-
Data de disponibilização: dc.date.available2024-07-11T18:33:51Z-
Data de envio: dc.date.issued2020-11-17-
Data de envio: dc.date.issued2020-11-17-
Data de envio: dc.date.issued2015-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/15999-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/772982-
Descrição: dc.descriptionEste estudo tem como objetivo avaliar a capacidade da tomografia computadorizada de feixe cônico na mensuração da espessura do tecido gengival para auxiliar o planejamento de cirurgias periodontais e periimplantares. A espessura real obtida por meio de perfuração e aferição com paquímetro digital foi comparada com as medidas obtidas pelos exames tomográficos, utilizando duas metodologias distintas (a primeira fazendo uso de moldeira individual e marcações com guta-percha e medições diretas no exame tomográfico, sem auxílio de quaisquer aparatos como referência). Os indivíduos envolvidos foram incluídos de acordo com padrões préestabelecidos. As análises tomográficas foram realizadas por outro examinador. Os resultados mostraram que clinicamente os caninos apresentam a menor aferição em ambas as arcadas e os incisivos centrais a maior aferição. Diferentemente dos resultados tomográficos, em que os incisivos laterais, em ambas as arcadas, apresentam a menor aferição. Conclui-se necessária uma metodologia mais apurada capaz de avaliar a ocorrência de isomeria de resultados na reprodução destas avaliações em um mesmo individuo-
Descrição: dc.descriptionThis study aims to evaluate the ability of CT cone beam to measure the thickness of the gum tissue to assist the planning of periodontal and peri-implant surgery. The real thickness obtained through drilling and measurement with digital caliper was compared to the measurements obtained by CT scans using two different methodologies (the first making use of custom tray and markings with gutta-percha and direct measurements in CT examination without aid apparatus of any reference). The individuals involved were included in accordance with established standards. The tomographic analyzes were performed by another examiner. The results showed that clinically canines have the lowest measurement in both arches and central incisors most measurement. Unlike the tomographic results in that the lateral incisors in both jaws, have the lowest measurement. The conclusion is necessary a more accurate methodology to evaluate the occurrence of isomerism results in the reproduction of these assessments in the same individual-
Descrição: dc.description33f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nc-nd/3.0/br/-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectEspessura gengival-
Palavras-chave: dc.subjectTomografia computadorizada de feixe cônico-
Palavras-chave: dc.subjectBiótipo periodontal-
Palavras-chave: dc.subjectTomografia computadorizada de feixe cônico-
Palavras-chave: dc.subjectGengiva-
Palavras-chave: dc.subjectCirurgia periodontal-
Palavras-chave: dc.subjectGingival thickness-
Palavras-chave: dc.subjectCone-beam CT-
Palavras-chave: dc.subjectPeriodontal biotype-
Título: dc.titleAvaliação da fidelidade dimensional na utilização da tomografia computadorizada de feixe cônico na mensuração da espessura gengival-
Título: dc.titleDimensional fidelity assessment in the use of computed tomography cone beam to measure the gingival thickness-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.