Correlação entre a emissão otoacústica e a timpanometria com tom sonda de 226 Hz e tom sonda de 1000 Hz em recém-nascidos de unidade de neonatologia

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorVieira, Alan Araújo-
Autor(es): dc.contributorhttp://lattes.cnpq.br/9230494942501442-
Autor(es): dc.contributorMiterhof, Maria Elisa Vieira da Cunha Ramos-
Autor(es): dc.contributorhttp://lattes.cnpq.br/3256507816253760-
Autor(es): dc.contributorRamos, José Roberto de Moraes-
Autor(es): dc.contributorhttp://lattes.cnpq.br/9592920962692367-
Autor(es): dc.contributorAlbertino, Sérgio-
Autor(es): dc.contributorhttp://lattes.cnpq.br/0193327922022996-
Autor(es): dc.contributorSias, Selma Maria de Azevedo-
Autor(es): dc.contributorhttp://lattes.cnpq.br/6571323597413226-
Autor(es): dc.contributorhttp://lattes.cnpq.br/0447117066474755-
Autor(es): dc.creatorFaria, Armanda de Oliveira Pache de-
Data de aceite: dc.date.accessioned2024-07-11T18:31:25Z-
Data de disponibilização: dc.date.available2024-07-11T18:31:25Z-
Data de envio: dc.date.issued2023-09-25-
Data de envio: dc.date.issued2023-09-25-
Fonte completa do material: dc.identifierhttp://app.uff.br/riuff/handle/1/30557-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/772171-
Descrição: dc.descriptionContém tabelas e ilustrações-
Descrição: dc.descriptionINTRODUÇÃO: A Triagem Auditiva Neonatal (TAN - Emissões Otoacústicas Evocadas Transientes e PEATE/BERA) pode ter seus resultados prejudicados por alterações transitórias de orelha externa e média. Dessa forma, há na literatura uma sugestão de associar à TAN a avaliação da orelha média. Atualmente, a imitanciometria vem sendo indicada para tal, contudo, ainda há controvérsia sobre qual o melhor tom de sonda a ser utilizado. OBJETIVO: Analisar o grau de correlação das respostas das Emissões Otoacústicas Evocadas Transientes (EOAT) com os resultados da timpanometria obtidos com tom sonda de 226 Hz e tom sonda de 1000 Hz em recém-nascidos prematuros e a termo. MÉTODO: Estudo prospectivo no qual foram estudados os recém-nascidos que permaneceram internados na Unidade neonatal (Unidade de cuidados intermediários neonatal e Unidade de tratamento intensivo neonatal) do Hospital Universitário Antônio Pedro (HUAP). Estes foram submetidos à timpanometria com tom sonda de 226 Hz e tom sonda de 1000 Hz e à triagem auditiva por meio das Emissões Otoacústicas Evocadas Transientes. As curvas timpanométricas foram classificadas em normal (tipo A e Duplo Pico) ou alteradas (tipo Ad, As, B, C). A população estudada foi descrita por meio de frequências absolutas e relativas, e a correlação entre os resultados dos exames realizados foi estabelecida por meio do teste Qui-Quadrado e por Regressão logística, levando-se em consideração a significância de 95%, utilizando-se o pacote estatístico SPSS 16.0. O trabalho foi aprovado pelo Comitê de Ética e Pesquisa. RESULTADOS: Dos 172 pacientes admitidos na unidade neonatal do HUAP, preencheram os critérios de inclusão 137 recém-nascidos, perfazendo 274 orelhas. Destes, 22 apresentaram EOAT alteradas, 14 timpanometrias com tom sonda de 226 Hz e 18 timpanometrias com tom sonda de 1000 Hz. Ter OEAT alterada no primeiro exame aumenta em 44 vezes a chance de ter timpanometria com tom sonda de 226 Hz alterada (IC 95%: 11,75 – 166,81; p < 0,001) e em 829 vezes a chance de ter timpanometria com tom sonda de 1000 Hz alterada (IC 95%: 100,2 – 6879,17; p < 0,001). Na segunda avaliação, não houve correlação entre as medidas de EOAT e timpanometria com tom sonda de 226 Hz, no entanto, a timpanometria com tom sonda de 1000 Hz ainda apresentou boa correlação (OR 33; IC 95%: 1,74 – 627,28; p = 0,02). CONCLUSÃO: Houve melhor correlação entre os resultados das EOAT com a timpanometria com tom sonda de 1000 Hz na população estudada.-
Descrição: dc.descriptionINTRODUCTION: Neonatal Hearing Screening (Transient Evoked Otoacoustic Emissions and ABR) may have their results affected by transient changes of external and middle ear. Thus, there is a suggestion in the literature to associate the evaluation of the middle ear to the Neonatal Hearing Screening protocols. Currently, immitanciometry has been recommended for this, however, there is still controversy about the best probe tone to be used. OBJECTIVE: To analyze the correlation of Transient Evoked Otoacoustic Emissions (TEOAE) responses with tympanometry results obtained with 226 Hz probe tone and 1000 Hz probe tone in preterm and full term infants. METHODS: A prospective study where all infants who remained in the Antônio Pedro University Hospital Neonatal unit (Neonatal intermediate care unit and Neonatal intensive care unit) were studied. These subjects were submitted to tympanometry of 226 Hz probe tone and 1000 Hz probe tone and hearing screening through Transiet Evoked Otoacoustic Emissions. Tympanometric curves were classified as normal (type A and Double Peak) or abnormal (type Ad, As, B, C). The study population was described by absolute and relative frequencies and the correlation between the results of the examinations was compared using the chi-square test and logistic regression, taking into account the significance of 95%, using the statistical package SPSS 16.0. The study was approved by the Research Ethics Committee. RESULTS: Of the 172 patients admitted to the HUAP neonatal unit, 137 newborns met the inclusion criteria, totaling 274 ears. Of these, 22 had absent TEOAE, 14 tympanometry with 226 Hz probe tone and 18 tympanometry with 1000 Hz probe tone. Having absent TEOAE at the first examination, increases by 44 times the chance of having abnormal tympanometry with 226 Hz probe tone (IC 95%: 11.75 to 166.81, p <0.001) and 829 times the chance of having abnormal tympanometry with 1000Hz probe tone (95% CI: 100.2 to 6879.17; p <0.001). In the second evaluation, there was no correlation between measures of TEOAE and tympanometry with 226 Hz probe tone, however, the tympanometry with 1000Hz probe tone still showed good correlation (OR 33, 95% CI: 1.74 to 627, 28; p = 0.02). CONCLUSION: There was a better correlation between the results of Otoacoustic Emissions with tympanometry with 1000 Hz probe tone in the population.-
Descrição: dc.description89 f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectTestes de impedância acústica-
Palavras-chave: dc.subjectOrelha média-
Palavras-chave: dc.subjectEmissões otoacústicas evocadas transientes-
Palavras-chave: dc.subjectRecém-nascido-
Palavras-chave: dc.subjectTeste de impedância acústica-
Palavras-chave: dc.subjectOrelha média-
Palavras-chave: dc.subjectEmissões Otoacústicas Espontâneas-
Palavras-chave: dc.subjectAudiometria de resposta evocada-
Palavras-chave: dc.subjectRecém-nascido-
Palavras-chave: dc.subjectAcoustic impedance tests-
Palavras-chave: dc.subjectMiddle ear-
Palavras-chave: dc.subjectTransient evoked otoacoustic emissions-
Palavras-chave: dc.subjectNewborn-
Título: dc.titleCorrelação entre a emissão otoacústica e a timpanometria com tom sonda de 226 Hz e tom sonda de 1000 Hz em recém-nascidos de unidade de neonatologia-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.