Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Monteiro, Alessandra da Rocha Duailibe | - |
Autor(es): dc.contributor | http://lattes.cnpq.br/4706525645223041 | - |
Autor(es): dc.contributor | Soares, André Von Held | - |
Autor(es): dc.contributor | Gama, Antonio Lopes | - |
Autor(es): dc.contributor | http://lattes.cnpq.br/6355650046004754 | - |
Autor(es): dc.creator | Pereira, Eduardo Haddad Leite | - |
Autor(es): dc.creator | Silva, Gabriel Marinho da | - |
Data de aceite: dc.date.accessioned | 2024-07-11T18:27:19Z | - |
Data de disponibilização: dc.date.available | 2024-07-11T18:27:19Z | - |
Data de envio: dc.date.issued | 2022-07-27 | - |
Data de envio: dc.date.issued | 2022-07-27 | - |
Data de envio: dc.date.issued | 2021 | - |
Fonte completa do material: dc.identifier | http://app.uff.br/riuff/handle/1/25857 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/770900 | - |
Descrição: dc.description | Ao observar o desenvolvimento urbano ocorrido na cidade do Rio de Janeiro, no período entre o final dos anos 1960 e início dos anos de 1970, é perceptível o grande avanço ocorrido no setor da construção civil. Concomitantemente com este avanço, os tipos de construção tornaram-se cada vez mais complexos e novas tecnologias foram implementadas. No que se refere aos sistemas de refrigeração instalados, é importante ter conhecimento de como transcorreu a execução desses projetos, tendo em vista equipamentos, componentes e tubulações utilizadas, neste caso, tubulações de ligas metálicas. Considerando a motivação descrita, este trabalho tem como objetivo caracterizar os efeitos da corrosão em tubulações presentes em um Sistema de Refrigeração Predial, com foco em tubulações metálicas, sendo estes, efeitos que podem causar problemas de grande magnitude no que se refere ao funcionamento do sistema de refrigeração, quando não trabalhando de modo correto, podem ocorrer acidentes de grandes escalas que podem até mesmo levar a mortes em grande escala. Ao final, foi realizado um estudo de caso de um sistema de refrigeração predial em um edifício comercial na cidade do Rio de Janeiro datado do ano de 1975, utilizando uma amostra de tubo metálico, condutor de água quente ou fria. Esses materiais foram caracterizados pelas técnicas de Espectroscopia de Raios-X por Dispersão de Energia (EDX) e Difração de Raios-X (DRX); determinar a composição da amostra e caracterizar os produtos da corrosão decorrente do fluxo hídrico do sistema ao longo dos anos. Pôde-se observar a presença majoritária de ferro para a amostra retirada do corpo de prova que estava visualmente mais deteriorado, com 98,123 %, e Zinco para o corpo de prova que estava visualmente menos deteriorado, com 98,438%. Outro fator importante para fins comparativos, do ensaio realizado nas 2 amostras, é observar que a amostra retirada do corpo de prova menos deteriorado apresentou uma quantidade de elementos químicos presentes maior do que a amostra retirada do corpo de prova mais deteriorado. Para o ensaio DRX, para a amostra retirada da extremidade do corpo de prova mais deteriorado, foram registradas as presenças de ZnO (óxido de zinco, Zincita), e também o Fe. Para a amostra retirada da parte central do corpo de prova mais deteriorado foram registrados picos de intensidade que representam o Fe. Ambas as amostras mostraram um resultado com picos mais elevados no Fe. Para a amostra retirada da parte extrema do corpo de prova menos deteriorado foram registrados picos de intensidade que representam o ZnO (Zincita) e picos de intensidade que representam o Fe e, por último, picos nos quais estão representados o Zn (Zinco) presentes na amostra. Para a amostra retirada da parte central do corpo de prova menos deteriorado foram registrados picos de intensidades que representam o ZnO (Zincita), Fe (Ferro),Zn (Zinco) e também um pico que representa o Zn(OH)2 (Hidrozincita) presentes nesta amostra. Ou seja, todos os resultados que foram obtidos, corroboram o fato que ambos os corpos de provas passaram por um processo corrosivo intenso, durante os anos de vida útil que tiveram como componentes do sistema de refrigeração predial deste edifício comercial presente na cidade do Rio de Janeiro. | - |
Descrição: dc.description | When observing the urban development that occurred in the city of Rio de Janeiro in the period between the late 1960s and early 1970s, it is noticeable the great advance that occurred in the civil construction sector. Concomitantly with this advance, the types of construction became more and more complex and new technologies were implemented. Regarding the installed refrigeration systems, it is important to have knowledge of how the execution of these projects took place, in view of equipment, components and pipes used, in this case, metal alloy pipes. Considering the motivation described above, this paper aims to characterize the effects of corrosion in pipes present in a Building Refrigeration System, focusing on metal pipes, which are effects that can cause problems of great magnitude with regard to the operation of the refrigeration system when not working properly, large-scale accidents can occur that can even lead to large-scale fatalities.At last, a case study of a building refrigeration system in a commercial building in the city of Rio de Janeiro dated from the year 1975 was performed, using a sample of metallic tube, conductor of hot or cold water. These materials were characterized by Energy Dispersive X-ray Spectroscopy (EDX) and X-ray Diffraction (XRD) techniques; to determine the sample composition and to characterize the corrosion products resulting from the water flow of the system over the years. A majority of iron was present in the sample taken from the most visually deteriorated specimen at 98.123%, and Zinc was present in the least visually deteriorated specimen at 98.438%. Another important factor for comparative purposes, of the test performed on the two samples, is to observe that the sample taken from the less deteriorated specimen presented a greater amount of chemical elements present than the sample taken from the more deteriorated specimen. For the XRD test, for the sample taken from the edge of the more deteriorated specimen, the presence of ZnO (zinc oxide, Zincite), and also Fe were recorded. For the sample taken from the center of the most deteriorated specimen, peaks representing Fe were recorded.Both samples showed a result with higher peaks in Fe. For the sample taken from the extreme part of the less deteriorated specimen, intensity peaks representing ZnO (Zincite) and intensity peaks representing Fe were recorded, and finally peaks representing Zn (Zinc) present in the sample. For the sample taken from the central part of the least deteriorated specimen, peaks of intensities representing ZnO (Zincite), Fe (Iron), Zn (Zinc) and also a peak representing Zn(OH)2 (Hydrozincite) present in this sample were recorded.Thus, all the results that were obtained corroborate the fact that both specimens went through an intense corrosive process during the years of their useful life as components of the building cooling system of this commercial building in the city of Rio de Janeiro. | - |
Descrição: dc.description | 96 p. | - |
Formato: dc.format | application/pdf | - |
Idioma: dc.language | pt_BR | - |
Direitos: dc.rights | Open Access | - |
Direitos: dc.rights | CC-BY-SA | - |
Palavras-chave: dc.subject | Corrosão | - |
Palavras-chave: dc.subject | Tubulações | - |
Palavras-chave: dc.subject | Aço Galvanizado | - |
Palavras-chave: dc.subject | Sistema de Refrigeração Predial | - |
Palavras-chave: dc.subject | Corrosão | - |
Palavras-chave: dc.subject | Sistema de refrigeração | - |
Palavras-chave: dc.subject | Difração de raios X | - |
Palavras-chave: dc.subject | Corrosion | - |
Palavras-chave: dc.subject | Piping | - |
Palavras-chave: dc.subject | Galvanized Steel | - |
Palavras-chave: dc.subject | Building Refrigeration System | - |
Título: dc.title | Caracterização da corrosão interna de tubulações em um sistema de refrigeração predial | - |
Tipo de arquivo: dc.type | Trabalho de conclusão de curso | - |
Aparece nas coleções: | Repositório Institucional da Universidade Federal Fluminense - RiUFF |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: