Avaliação da resistência à corrosão de liga biocompatível Ti-6AI-7Nb anodizada por microarco a -27ºC e +25ºC

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorFerreira, Elivelton Alves-
Autor(es): dc.contributorhttp://lattes.cnpq.br/9791486511562981-
Autor(es): dc.contributorMota, Izabel de Oliveira da-
Autor(es): dc.contributorhttp://lattes.cnpq.br/4641115930599322-
Autor(es): dc.contributorSilva, Ladário da-
Autor(es): dc.contributorhttp://lattes.cnpq.br/3743563498830737-
Autor(es): dc.creatorLarcher, Elaine Cristina Batista Aloisio-
Data de aceite: dc.date.accessioned2024-07-11T18:23:50Z-
Data de disponibilização: dc.date.available2024-07-11T18:23:50Z-
Data de envio: dc.date.issued2022-11-03-
Data de envio: dc.date.issued2022-11-03-
Fonte completa do material: dc.identifierhttp://app.uff.br/riuff/handle/1/26813-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/769724-
Descrição: dc.descriptionO presente trabalho relata o comportamento de proteção dos revestimentos obtidos pela Oxidação Anódica a Microarco (MAO) sobre a liga Ti6Al7Nb na solução 3mol/L KOH e 1,1 mol/L Na2SiO3 anodizada em diferentes temperaturas: a 27° C e a + 25°C. O titânio e suas ligas são utilizados nas mais diversas áreas e aplicações industriais e biomédicas. Possuem uma camada natural, fina e aderente de óxido na sua superfície que funciona como uma barreira contra corrosão. Esta resistência à corrosão e a biocompatibilidade podem ser melhorados através de técnicas de anodização. Neste trabalho foram realizadas anodizações pelo método MAO e os óxidos formados foram caracterizados por Difração de RaiosX e analisados pelo Microscópio Eletrônico de Varredura. Além disso, a técnica de Microscopia Confocal verificou a rugosidade do filme protetivo formado. Estas analises permitiram inferir que o óxido predominante é o TiO2, sendo parcialmente cristalino, com a presença da fase anatase. A resistência à corrosão foi avaliada por meio de medidas do potencial a circuito aberto (OCP) em função do tempo, ensaios eletroquímicos de Espectroscopia de Impedância Eletroquímica (SEM) e curvas de polarização potenciodinâmica (CP). Os ensaios eletroquímicos foram realizados em solução de Hank, mostrando que o processo de anodização, assim como a modificação da composição das amostras anodizadas em temperaturas negativas melhoraram significativamente a resistência à corrosão da liga.-
Descrição: dc.descriptionThe present work reports the protective behavior of coatings obtained by Oxidation Microarco Anodic (MAO) over Ti6Al7Nb alloy in 3mol / L KOH and 1.1 mol / L Na2SiO3 solution anodized at different temperatures: 27 ° C and + 25 ° C. Titanium and its alloys are used in more diverse areas and industrial and biomedical applications. They have a natural, thin and adherent layer of oxide on its surface that acts as a barrier against corrosion. This corrosion resistance and biocompatibility can be improved through anodizing techniques. In this work, anodisations performed by the MAO method and the oxides formed were characterized by Diffraction of Xrays and analyzed by the Scanning Electron Microscope. In addition, the Microscopy technique Confocal verified the roughness of the formed protective film. These analyzes allowed infer that the predominant oxide is TiO2, being partially crystalline, with the presence of the anatase. Corrosion resistance was assessed using open circuit potential (OCP) measurements as a function of time, electrochemical tests of Electrochemical Impedance Spectroscopy (SEM) and potentiodynamic polarization (CP) curves. Electrochemical tests were performed in solution Hank, showing that the anodizing process, as well as the modification of the composition of the anodized samples at negative temperatures significantly improved corrosion resistance of the alloy.-
Descrição: dc.description113 p.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectLiga Ti-6Al-7Nb-
Palavras-chave: dc.subjectOxidação anódica-
Palavras-chave: dc.subjectRevestimento MAO-
Palavras-chave: dc.subjectPotencial em circuito aberto-
Palavras-chave: dc.subjectCurva de polarização-
Palavras-chave: dc.subjectResistência à corrosão-
Palavras-chave: dc.subjectOxidação anódica de metais-
Palavras-chave: dc.subjectAnodização-
Palavras-chave: dc.subjectProcessamento e caracterização de materiais-
Palavras-chave: dc.subjectEngenharia Metalúrgica-
Palavras-chave: dc.subjectProdução intelectual-
Palavras-chave: dc.subjectTi-6Al-7Nb alloy-
Palavras-chave: dc.subjectAnodic oxidation-
Palavras-chave: dc.subjectMAO coating-
Palavras-chave: dc.subjectOpen circuit potential-
Palavras-chave: dc.subjectPolarization curve-
Título: dc.titleAvaliação da resistência à corrosão de liga biocompatível Ti-6AI-7Nb anodizada por microarco a -27ºC e +25ºC-