Ação das forças ortodônticas na retração de dentes inferiores com a utilização de mini-implantes

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorMucha, José Nelson-
Autor(es): dc.contributorSaramago, Adriana Cury-
Autor(es): dc.contributorNeves, Regina Maria Lopes-
Autor(es): dc.contributorBrandão, Roberto Carlos Bodart-
Autor(es): dc.contributorPenedo, Norman Duque-
Autor(es): dc.creatorCapucho, Larissa Bustamante-
Data de aceite: dc.date.accessioned2024-07-11T18:23:19Z-
Data de disponibilização: dc.date.available2024-07-11T18:23:19Z-
Data de envio: dc.date.issued2018-07-24-
Data de envio: dc.date.issued2018-07-24-
Data de envio: dc.date.issued2007-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/7097-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/769539-
Descrição: dc.descriptionObjetivos: Analisar a decomposição de diferentes linhas de ação de forças nos movimentos de retração dos dentes anteriores inferiores, com a utilização de mini-implantes na região posterior e ganchos anteriores. Metodologia: A partir de seis Ilustrações gráficas tridimensionais, em tamanho real de dentes e mandíbulas, obtidas de imagens Tomográficas Computadorizadas (TC), de paciente adulto portador de Classe I biprotrusão com indicação de extrações de pré-molares, foram simuladas 6 linhas de ação de forças, com a aplicação de 3N, para a retração dos dentes anteriores inferiores. Foram realizadas variações verticais na posição dos mini-implantes entre primeiro e segundo molar inferior e nos ganchos entre incisivo lateral e canino. Resultados: 1- Com mini-implante a 3mm da crista óssea e a aplicação da força na região anterior: a) ao nível do arco ortodôntico, a força de retração foi de 2,70N, expansão de 1,26N e intrusão de 0,28N; b) a 3mm do nível do arco, retração de 2,71N, expansão de 1,26N e intrusão de 0,01N; c) a 5mm do nível do arco, retração de 2,71N, expansão de 1,26N e extrusão de 0,15N. 2-) Mini-implante a 5mm da crista e força anterior: d) ao nível do arco, retração de 2,68N, expansão de 1,25N e intrusão de 0,45N; e) a 3mm do arco, retração de 2,61N, expansão de 1,26N e intrusão de 0,19N; f) a 5mm do arco ortodôntico, retração de 2,71N, expansão de 1,26N e intrusão de 0,01N. Conclusões: O entendimento das linhas de ação de forças e suas decomposições são fundamentais para se alcançar os resultados desejados nas diferentes maloclusões, visando o controle tridimensional do movimento dentário.-
Descrição: dc.descriptionObjective: Analyze the decomposition of action’s force lines in 6 different situations to retract the lower anterior teeth with mini-implants in the posterior area and hooks in the anterior region. Methodology: In three-dimensional graphic Illustrations in real size of teeth and jaws, obtained from images generated by tomography computerized (TC) of an adult patient, with Class I biprotrusion malocclusion and premolar extractions indication, were simulated 6 action’s lines force, with the application of 3N, to retract the anterior teeth. Vertical variations were accomplished in the position of the mini-implants between first and second molars and hooks between lateral and canine. Results: 1- With mini-implant to 3mm of the bony crest and the anterior force application: a) at the level of the orthodontic archwire, the retraction was of 2,70N, expansion of 1,26N and intrusion of 0,28N; b) 3mm lower to the archwire, retraction of 2,71N, expansion of 1,26N and intrusion of 0,01N; c) 5mm inferior to the archwire, retraction of 2,71N, expansion of 1,26N and extrusion of 0,15N. 2- Mini-implant to 5mm of the crest and anterior force: d) at the level of the archwire, retraction of 2,68N, expansion of 1,25N and intrusion of 0,45N; e) 3mm inferior of the archwire, retraction of 2,61N, expansion of 1,26N and intrusion of 0,19N; f) 5mm of the archwire, retraction of 2,71N, expansion of 1,26N and intrusion of 0,01N. Conclusions: The understanding of the action’s force lines and its decompositions are essential to reach the results intended in the different malocclusions, aiming the three-dimensional control of the dental movement.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Publicador: dc.publisherUniversidade Federal Fluminense-
Publicador: dc.publisherNiterói-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectDecomposição de forças-
Palavras-chave: dc.subjectBiomecânica ortodôntica-
Palavras-chave: dc.subjectMini-implantes na mandíbula-
Palavras-chave: dc.subjectRetrações dentárias-
Palavras-chave: dc.subjectOrtodontia-
Palavras-chave: dc.subjectImplante dentário-
Palavras-chave: dc.subjectBiomecânica ortodôntica-
Palavras-chave: dc.subjectForces decomposition-
Palavras-chave: dc.subjectOrthodontic biomechanics-
Palavras-chave: dc.subjectMini-implants in mandible-
Palavras-chave: dc.subjectDental retractions-
Título: dc.titleAção das forças ortodônticas na retração de dentes inferiores com a utilização de mini-implantes-
Tipo de arquivo: dc.typeTrabalho de conclusão de curso-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.