Análise da magnitude de tensão e perdas técnicas na rede de distribuição para diferentes níveis de penetração de GD fotovoltaica

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorBorba, Bruno Soares Moreira Cesar-
Autor(es): dc.contributorAbud, Tiago Pires-
Autor(es): dc.contributorMartins, Flávio Goulart dos Reis-
Autor(es): dc.contributorDias, Daniel Henrique Nogueira-
Autor(es): dc.creatorGonçalves Júnior, Fernando Antonio da Cruz-
Data de aceite: dc.date.accessioned2024-07-11T18:21:30Z-
Data de disponibilização: dc.date.available2024-07-11T18:21:30Z-
Data de envio: dc.date.issued2023-07-28-
Data de envio: dc.date.issued2023-07-28-
Fonte completa do material: dc.identifierhttp://app.uff.br/riuff/handle/1/29502-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/768965-
Descrição: dc.descriptionA Geração Distribuída tem crescido de forma vertiginosa no Brasil e no mundo nos últimos anos, sobretudo a fonte solar, a qual tem se difundido entre os mais variados perfis de consumidores. Entre os seus benefícios é possível citar o retorno econômico devido a diminuição do gasto com energia elétrica e a contribuição para um meio ambiente mais sustentável, visto que se trata de fontes renováveis. Entretanto, a inserção de novos sistemas fotovoltaicos na rede de distribuição pode causar diversos impactos negativos, pois, de maneira geral, a rede não tem a estrutura necessária para receber a geração pelo lado do consumidor. Alguns desses impactos são sobretensão, aumento das perdas técnicas devido ao fluxo reverso, entre outros. Dessa forma, é preciso verificar a penetração máxima de GD que pode ser conectada à rede, sem causar efeitos indesejados. Portanto, este trabalho tem como objetivo realizar um estudo utilizando o software Open Distribution System Simulator (OpenDSS) com a rede de testes de 13 barras do Institute of Electrical and Electronic Engineers (IEEE), onde foram efetuadas inserções de GD fotovoltaica em diferentes níveis de penetração. Após as simulações, foram analisadas situações de possíveis sobretensões e aumento/diminuição das perdas técnicas. Os resultados mostraram que é possível reduzir as perdas e melhorar o perfil de tensão da rede para determinados valores de penetração fotovoltaica, porém, para níveis mais altos de penetração, houve aumento das perdas e violação dos parâmetros de tensão exigidos pela Agência Nacional de Energia Elétrica (ANEEL).-
Descrição: dc.descriptionDistributed generation has grown exponentially in Brazil and around the world in the last few years, mainly the solar power, which has spread among different types of consumers. Among its benefits, it's possible to mention the economic return due to the reduction of the expenses with electrical energy and the contribution to a more sustainable environment since it involves renewable sources. However, inserting new photovoltaic systems in the distribution network can cause many negative impacts because, in general, the network doesn't have the necessary structure to receive the generation from the consumer. Some of these impacts are overvoltage, increase of the technical losses due the reverse flow, among others. In that way, it is necessary to verify the maximum penetration of DG that can be connected to the network without causing undesirable effects. Therefore, this work has the objective to conduct a study using the software Open Distribution System Simulator (OpenDSS) with the testing network IEEE 13 Node Test Feeder, where photovoltaic DG has been inserted with different levels of penetration. After the simulations, situations of possible overvoltage and increase/decrease of technical losses were analyzed. The results showed that is possible to reduce the losses and improve the profile of the voltage of the network to some values of photovoltaic penetration. However, for higher levels of penetration, there has been an increase in losses and the violation of the voltage parameters demanded by the National Agency of Electrical Power (ANEEL)-
Descrição: dc.description66 p.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectGeração Distribuída (GD)-
Palavras-chave: dc.subjectSobretensão-
Palavras-chave: dc.subjectPerdas técnicas-
Palavras-chave: dc.subjectPenetração fotovoltaica-
Palavras-chave: dc.subjectFluxo reverso-
Palavras-chave: dc.subjectSistema fotovoltaico-
Palavras-chave: dc.subjectGeração de energia-
Palavras-chave: dc.subjectRede elétrica-
Palavras-chave: dc.subjectSimulação por computador-
Palavras-chave: dc.subjectDistributed generation (DG)-
Palavras-chave: dc.subjectOvervoltage-
Palavras-chave: dc.subjectTechnical losses-
Palavras-chave: dc.subjectPhotovoltaic penetration-
Palavras-chave: dc.subjectReverse flow-
Título: dc.titleAnálise da magnitude de tensão e perdas técnicas na rede de distribuição para diferentes níveis de penetração de GD fotovoltaica-