Análise dos reguladores de tensão em redes com alta penetração de geração distribuída fotovoltaica: uma perspectiva do consumidor industrial

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorMonteiro, Paulo Roberto Duailibe-
Autor(es): dc.contributorhttp://lattes.cnpq.br/6842845032046691-
Autor(es): dc.contributorBorges, Thiago Trezza-
Autor(es): dc.contributorhttp://lattes.cnpq.br/2818644535142542-
Autor(es): dc.contributorFortes, Marcio Zamboti-
Autor(es): dc.contributorOliveira, Cintia Machado de-
Autor(es): dc.contributorhttp://lattes.cnpq.br/7282315359449549-
Autor(es): dc.creatorGama, Leandro Pereira da-
Data de aceite: dc.date.accessioned2024-07-11T18:20:47Z-
Data de disponibilização: dc.date.available2024-07-11T18:20:47Z-
Data de envio: dc.date.issued2023-01-11-
Data de envio: dc.date.issued2023-01-11-
Fonte completa do material: dc.identifierhttp://app.uff.br/riuff/handle/1/27522-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/768728-
Descrição: dc.descriptionEste trabalho aborda os conceitos e as implicações da utilização da geração distribuída (GD) fotovoltaica nas redes elétricas de média e baixa tensão. Em particular, são avaliados os possíveis impactos causados aos reguladores de tensão e às indústrias de média tensão ao longo da rede de distribuição. Para isso, são apresentadas as principais normas e regulamentações que devem ser atendidas para a implementação dos reguladores de tensão, além dos principais parâmetros que servem de base para análise da qualidade de energia. Como objetivo primário, este trabalho visa analisar os impactos da penetração das GDs fotovoltaicas na rede elétrica de média e baixa tensão. O objetivo secundário visa analisar os impactos provocados pelas GDs aos reguladores de tensão instalados ao longo da rede, com a finalidade de melhorar a qualidade de energia, conforme as recomendações do PRODIST e os impactos causados pelas GDs nas indústrias. Tais verificações tornam-se ainda mais relevantes quando aplicadas em topologias complexa da rede, além da carência de adequações em vários centros urbanos ao longo dos anos. A análise considerou a variação do nível de geração das GDs em 2 cenários. Os cenários analisam a operação de 3 reguladores de tensão alocados ao longo da rede de distribuição e na qualidade da energia entregue em 3 indústrias. Para isso foram utilizadas simulações através do programa computacional OpenDSS. O primeiro cenário é realizado para verificação do comportamento dos reguladores, incluindo casos sem a penetração de GDs, e com penetração de GDs de 50 %, 70 % e 90 % em relação a capacidade do transformador. O segundo cenário visa avaliar o comportamento do OLTC (On-load tap changer) dos transformadores das indústrias, em rede sem GD e com GD, no que tange ao aspecto da manutenção e qualidade de energia entregue nas indústrias. Neste sentido, esse trabalho apresenta a análise dos parâmetros de qualidade de energia que são violados nas indústrias da rede de média tensão, pela inserção das GDs fotovoltaicas na rede de média e baixa. Os parâmetros avaliados são: tensão em regime permanente, fator de potência, desequilíbrio de tensão, perdas técnicas e fluxo de potência reverso. Tais análises foram realizadas utilizando o caso teste 8.500 barras do IEEE (Institute of Electrical and Electronics Engineers), disponível na biblioteca do OpenDSS.-
Descrição: dc.descriptionThis work addresses the concepts and implications of the use of photovoltaic distributed generation (DG) in medium and low-voltage electrical networks. In particular, the possible impacts caused to voltage regulators and medium voltage industries along the distribution network are evaluated. In this sense, the main standards and regulations that must be met for the implementation of voltage regulators, and the main parameters that serve as a basis for analyzing the power quality are discussed. As a primary objective, this work aims to analyze the impacts of the penetration of photovoltaic DGs in the medium and low voltage electrical network. The secondary objective aims to analyze the impacts caused by DGs on voltage regulators installed along with the network to improve energy quality, according to PRODIST recommendations, and the impacts caused by DGs in industries. Such verifications become even more relevant when applied in complex network topologies, in addition to the lack of adaptations in several urban centers over the years. The analysis considered the variation in the generation level of DGs in 2 scenarios. The scenarios analyze the operation of 3 voltage regulators allocated along with the distribution network and the quality of energy delivered in 3 industries. For this, simulations were used through the OpenDSS computer program. The first scenario is carried out to verify the behavior of the regulators, including cases without penetration of DGs, and with penetration of DGs of 50%, 70%, and 90% to the transformer capacity. The second scenario aims to evaluate the behavior of the OLTC (On-load tap changer) of the transformers of the industries, in a network without DG and with DG, regarding the aspect of maintenance and quality of energy delivered in the industries. In this sense, this work presents the analysis of power quality parameters that are violated in the medium voltage network industries, by the insertion of photovoltaic DGs in the medium and low networks. The parameters evaluated are steady-state voltage, power factor, voltage unbalance, technical losses, and reverse power flow. Such analyzes were performed using the 8500 bus test case from the IEEE (Institute of Electrical and Electronics Engineers), available in the OpenDSS library.-
Descrição: dc.description124 p.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectGeração distribuída-
Palavras-chave: dc.subjectRegulador de tensão-
Palavras-chave: dc.subjectTransformador-
Palavras-chave: dc.subjectEstudo de casos-
Palavras-chave: dc.subjectIntermitência fotovoltaica-
Palavras-chave: dc.subjectOLTC-
Palavras-chave: dc.subjectEnergia solar-
Palavras-chave: dc.subjectDistribuição de energia-
Palavras-chave: dc.subjectRegulador de tensão (Engenharia Elétrica)-
Palavras-chave: dc.subjectDistributed generation. Voltage regulator. Transformer. Case studies. Photovoltaic intermittency. Delay. Power quality. OLTC-
Palavras-chave: dc.subjectDistributed generation-
Palavras-chave: dc.subjectVoltage regulator-
Palavras-chave: dc.subjectTransformer-
Palavras-chave: dc.subjectCase studies-
Palavras-chave: dc.subjectPhotovoltaic intermittency-
Palavras-chave: dc.subjectDelay-
Título: dc.titleAnálise dos reguladores de tensão em redes com alta penetração de geração distribuída fotovoltaica: uma perspectiva do consumidor industrial-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF