Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Gouvêa, Cresus Vinícius Depes de | - |
Autor(es): dc.contributor | http://lattes.cnpq.br/0973157341889393 | - |
Autor(es): dc.contributor | http://lattes.cnpq.br/9924799549240650 | - |
Autor(es): dc.creator | Costa, André Salgado da | - |
Data de aceite: dc.date.accessioned | 2024-07-11T18:16:27Z | - |
Data de disponibilização: dc.date.available | 2024-07-11T18:16:27Z | - |
Data de envio: dc.date.issued | 2020-11-09 | - |
Data de envio: dc.date.issued | 2020-11-09 | - |
Data de envio: dc.date.issued | 2014 | - |
Fonte completa do material: dc.identifier | https://app.uff.br/riuff/handle/1/15859 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/767198 | - |
Descrição: dc.description | Este estudo mediu a angulação máxima entre dois implantes permitida pelas paredes internas de componentes do tipo UCLA rotacional em próteses múltiplas parafusadas. Trinta corpos de prova formados por 3 marcas diferentes (Conexão, São Paulo, Brasil; Neodent, Curitiba, Brasil; SIN, São Paulo, Brasil), composto por pilares de titânio rotacionais conectados a análogos de implante hexágono externo com plataforma regular 4.1, foram divididos em 3 grupos. Os corpos de prova foram preenchidos internamente com resina de poliéster, parafusados, torqueados e seccionados para avaliar o espaço existente entre a parede interna do UCLA rotacional e a aresta e vértice do hexágono. As medições foram realizadas com um equipamento 3D. Quando os hexágonos dos implantes foram posicionados aresta/aresta, os grupos 1,2 e 3 apresentaram 40,75, 45,00 e 31,89 graus respectivamente. Com os hexágonos posicionados vértice/vértice apresentou 9,79, 18,18 e 3,27 graus para os grupos 1, 2 e 3 respectivamente. A angulação máxima média no sentido mesio/distal entre 2 implantes com os hexágonos posicionados vértice a vértice é 10,41 graus e com os hexágonos posicionados aresta/aresta é 39,54 graus. Este estudo sugere diretrizes para posicionar os implantes de hexágono externo utilizados como bases de próteses múltiplas parafusadas, sem interferências, com componentes do tipo UCLA rotacional | - |
Descrição: dc.description | This study measured the maximum angulation between two implants allowed by the internal walls of the component in screw-retained multiple prostheses using rotational abutment-type components. Thirty specimens of 3 different brands (Conexão, São Paulo, Brazil; Neodent, Curitiba, Brazil; and SIN, São Paulo, Brazil), consisting of titanium rotational abutments connected to external hexagon abutment analogs, with standard platforms, were divided into 3 groups. The specimens were internally filled with polyester resin, screw retained, torqued and sectioned to assess the space existing between the internal wall of the rotational abutment component, edge and vertex of the hexagon. The measurements were performed using 3D equipment. When the implant hexagons were oriented edge-to-edge, group 1, 2 and 3 presented 40.75, 45.00 and 31.89 degrees, respectively. Vertex-to-vertex hexagon orientation showed 9.79, 18.18 and 3.27 degrees for groups 1, 2 and 3, respectively. The maximum mean angulation in the mesio/distal direction between the 2 implants with hexagon oriented vertex-to-vertex is 10.41 degrees, and hexagon oriented edge-to-edge is 39.54 degrees. This study suggests guidelines for positioning external hexagon implants for interference-free screw-retained multiple prostheses using rotational abutment-type componentes | - |
Descrição: dc.description | 30f. | - |
Formato: dc.format | application/msword | - |
Idioma: dc.language | pt_BR | - |
Direitos: dc.rights | openAccess | - |
Direitos: dc.rights | openAccess | - |
Direitos: dc.rights | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ | - |
Direitos: dc.rights | CC-BY-SA | - |
Palavras-chave: dc.subject | Implante dentário | - |
Palavras-chave: dc.subject | Abutment rotacional | - |
Palavras-chave: dc.subject | Implante hexágono externo | - |
Palavras-chave: dc.subject | Implante dentário | - |
Palavras-chave: dc.subject | Prótese dentária | - |
Palavras-chave: dc.subject | Dental implant | - |
Palavras-chave: dc.subject | Rotational abutment | - |
Palavras-chave: dc.subject | External hexagon implant | - |
Título: dc.title | Diretriz na instalação de implantes hexágono externo para próteses múltiplas parafusadas com componentes UCLA rotacional | - |
Título: dc.title | Guidelines for positioning external hexagon implants in screw-retained multiple prostheses using rotational abutment-type components | - |
Tipo de arquivo: dc.type | Dissertação | - |
Aparece nas coleções: | Repositório Institucional da Universidade Federal Fluminense - RiUFF |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: