Avaliação de compósitos restauradores fotoativáveis submetidos à simulação clínica em diferentes meios de imersão e profundidades

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorSilva, Eduardo Moreira da-
Autor(es): dc.contributorGuimarães, José Guilherme Antunes-
Autor(es): dc.contributorFaria, Lucianne Cople Maia de-
Autor(es): dc.creatorGonçalves, Luana-
Data de aceite: dc.date.accessioned2024-07-11T18:16:16Z-
Data de disponibilização: dc.date.available2024-07-11T18:16:16Z-
Data de envio: dc.date.issued2018-09-24-
Data de envio: dc.date.issued2018-09-24-
Data de envio: dc.date.issued2009-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/7662-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/767128-
Descrição: dc.descriptionO objetivo desta pesquisa foi avaliar os fenômenos de absorção e de solubilidade de um compósito nanoparticulado (Filtek Z350 3M) e um compósito híbrido (Filtek P60 3M) em diferentes meios de imersão e profundidade, avaliar o grau de conversão dos compósitos utilizados e avaliar a ação dos diferentes meios na degradação superficial dos compósitos. Para confecção do modelo experimental utilizou-se uma raiz de incisivo central bovino, onde foi confeccionada uma cavidade cilíndrica com 5mm de diâmetro e 8mm de profundidade. Esta cavidade foi preenchida com incrementos de 1mm do compósito, fotoativados por 20 segundos com irradiância de 650mW/cm2. Os cilindros de resina foram seccionados transversalmente em discos com 1mm de espessura até a profundidade de 5 mm. Os discos de cada compósito foram divididos em 15 grupos (n=5) de acordo como a profundidade (1, 2, 3, 4 e 5 mm) e o meio de imersão (água destilada, saliva artificial (ph neutro) e ácido lático (0,01 Molar). As análises de absorção e solubilidade foram realizadas com base na norma ISO 4049, a ação dos meios na superfície dos compósitos foi analisada através da microscopia eletrônica de varredura e o grau de conversão monomérica foi avaliado através de espectroscopia infravermelha com transformada de Fourier (FTIR). Os dados de absorção e solubilidade foram submetidos separadamente à análise de variância de três fatores e ao teste deTukey HSD (α= 0,05). Foram feitas análises de regressão linear para avaliar a correlação entre absorção e profundidade e solubilidade e profundidade. Os resultados obtidos para o grau de conversão foram analisados através do teste t-Student (α= 0,05). O compósito Z350 apresentou maior absorção e solubilidade do que o P60. A imersão em ácido lático gerou os maiores valores para ambos os fenômenos. Os maiores valores de absorção e de solubilidade para os dois compósitos foram encontrados na profundidade de 5mm (profundidade mais afastada da fonte de luz). Para o compósito P60, excetuando-se a profundidade de 4mm, a imersão em ácido lático ocasionou os maiores valores de absorção. Isso também foi observado para Z350, com exceção da profundidade de 3mm. O ácido lático ocasionou um maior efeito deletério na superfície dos compósitos. Não houve significância estatística entre os compósitos para o grau de conversão (p>0,05)-
Descrição: dc.descriptionThe aim of this study was to evaluate the sorption and the solubility phenomena of a nanofilled (Filtek Z350) and a hybrid resin composite (Filtek P60) as a function of depth and immersed in different media, as well as to evaluate the degree of conversion and the action of the media in the surface degradation of composites. In order to build the experimental model was used a bovine central incisor root and in this was made a cylindrical cavity with 5mm diameter and 8mm deep. The cylindrical cavity was filled with increments of 1mm of composites that were light-activated for 20 seconds with irradiance of 650mW/cm2. The obtained cylinders of composites were transversely sectioned in order to obtain disks of 1 mm in thickness. For each resin composite, 15 groups (n = 5) were divided according to the depth (1, 2, 3, 4 and 5 mm) and media immersion (distilled water, artificial saliva (pH neutral) and lactic acid (0.01M). The sorption and solubility were carried out based on ISO 4049; the action of media on the surface of composites was analyzed by scanning electron microscopy; and the degree of monomer conversion was measured by Fourier transformed infrared spectroscopy (FTIR). The data of absorption and solubility were tested separately by analysis of variance of three factors and the Tukey HSD test (α = 0.05). The linear regression model was used to evaluate the correlation between absorption and depth and solubility and depth too. The results obtained for the degree of conversion were analyzed using the t-Student test (α = 0.05). The Z350 presented higher solubility and sorption than P60. The immersion in lactic acid generated the highest values for both phenomena. For the two composites, the highest values of sorption and solubility were found at a depth of 5mm. For P60, except in the depth of 4mm, the immersion in lactic acid caused the highest value of sorption. This was also observed for Z350, except in the depth of 3mm. The effect of acid lactic on the composite surfaces was more deleterious than those of water and artificial saliva. The degree of conversion was not statiscally significant (p>0,05)-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nc-nd/3.0/br/-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectCompósitos fotoativáveis-
Palavras-chave: dc.subjectPartículas de carga-
Palavras-chave: dc.subjectGrau de conversão-
Palavras-chave: dc.subjectMaterial dentário-
Palavras-chave: dc.subjectTeste de material-
Palavras-chave: dc.subjectRestauração dentária-
Palavras-chave: dc.subjectSolubilidade-
Palavras-chave: dc.subjectLight-cured resin composites-
Palavras-chave: dc.subjectFiller particles-
Palavras-chave: dc.subjectDegree of conversion-
Título: dc.titleAvaliação de compósitos restauradores fotoativáveis submetidos à simulação clínica em diferentes meios de imersão e profundidades-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.