Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/763916-
Descrição: dc.descriptionCom o aumento da demanda energética e a crescente exigência de melhorias na transmissão de energia elétrica, aliados à desafiadora tarefa de instalar estruturas de grande porte, como subestações (SE’s), próximas aos consumidores finais, surge a necessidade premente de otimização dos recursos, visando à minimização de desperdícios. Nesse cenário, desperta-se um debate relevante acerca das distintas características construtivas entre as SE's isoladas a gás SF6 (GIS-Gas Insulated Switchgear) e as subestações com tecnologia convencional (AIS-Air Insulated Switchgear), principalmente no que se refere à área de implantação. O objetivo principal deste estudo é analisar as características das subestações isoladas a gás SF6 e das subestações convencionais, com detalhamento de sua estrutura, equipamentos e arranjos, além da avaliação do desempenho de duas instalações reais que se enquadram nesse contexto. Essas instalações em questão são a SE Adrianópolis (AIS), localizada em Nova Iguaçu, e a SE Grajaú (GIS), situada na cidade do Rio de Janeiro. O documento apresenta uma análise comparativa, levando em consideração parâmetros como tempo de indisponibilidade dos equipamentos levando em consideração o reparo de falhas, incidência de ocorrências e o defeito apresentados nos equipamentos de cada construção. Com base nas informações obtidas a partir das amostras analisadas, serão elaboradas eventuais conclusões acerca do desempenho dessas instalações-
Descrição: dc.descriptionWith the increasing demand for energy and the growing need for improvements in the transmission of electrical power, coupled with the challenging task of installing large structures such as substations (SEs) near end consumers, there arises an urgent need to optimize resources with a focus on minimizing waste. In this scenario, a relevant debate arises regarding the distinct construction characteristics between SF6-isolated gas substations (GIS - Gas Insulated Switchgear) and substations with conventional technology (AIS - Air Insulated Switchgear), particularly concerning the deployment area. The main objective of this study is to analyze the characteristics of SF6-isolated gas substations and conventional substations, providing detailed information on their structure, equipment, and arrangements. Additionally, the performance evaluation of two real installations fitting into this context is conducted. The installations in question are the Adrianópolis Substation (AIS) located in Nova Iguaçu and the Grajaú Substation (GIS) situated in the city of Rio de Janeiro. The document presents a comparative analysis, considering parameters such as equipment unavailability time, taking into account fault repair, incidence of occurrences, and defects in the equipment of each construction. Based on the information obtained from the analyzed samples, eventual conclusions will be drawn regarding the performance of these installations-
Descrição: dc.description65 f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectGás SF6-
Palavras-chave: dc.subjectSubestações-
Palavras-chave: dc.subjectGIS-
Palavras-chave: dc.subjectAIS-
Palavras-chave: dc.subjectDesempenho-
Palavras-chave: dc.subjectSubestação-
Palavras-chave: dc.subjectAvaliação de desempenho-
Palavras-chave: dc.subjectGás-
Palavras-chave: dc.subjectF6 Gas-
Palavras-chave: dc.subjectSubstations-
Palavras-chave: dc.subjectPerformance-