Resistência à fratura dos parafusos retentores das próteses parafusadas sobre componentes cônicos

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorGouvêa, Cresus Vinícius Depes de-
Autor(es): dc.contributorDias, Kátia Regina Hostilio Cervantes-
Autor(es): dc.contributorBarbosa, Eliane dos Santos Porto-
Autor(es): dc.contributorSampaio Filho, Helio Rodrigues-
Autor(es): dc.contributorhttp://lattes.cnpq.br/0424081639785731-
Autor(es): dc.contributorhttp://lattes.cnpq.br/9924799549240650-
Autor(es): dc.creatorMachado, Aldir Nascimento-
Data de aceite: dc.date.accessioned2024-07-11T18:06:21Z-
Data de disponibilização: dc.date.available2024-07-11T18:06:21Z-
Data de envio: dc.date.issued2019-06-11-
Data de envio: dc.date.issued2019-06-11-
Data de envio: dc.date.issued2008-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/9958-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/763626-
Descrição: dc.descriptionNeste ensaio laboratorial comparou-se a força máxima necessária a fratura dos parafusos retentores dos componentes cônicos das próteses parafusadas sobre implantes, que foram divididos em quatro grupos distintos de componentes, grupo 1 (cilindro de titânio para estheticone sobre análogo de estheticone preso por parafuso de ouro), grupo 2 ( cilindro de titânio para sobre análogo de estheticone preso por parafuso de titânio), grupo 3 (cilindro de titânio para miruscone sobre análogo de miruscone preso por parafuso de titânio), grupo 4 (cilindro de titânio para miruscone sobre análogo de miruscone preso por parafuso de ouro), todos com torque ou pré-carga de 20Ncm, instalados em uma base metálica de aço inoxidável na qual os dispositivos permaneciam a 45 graus de inclinação em relação ao longo eixo da força aplicada. Avaliou-se a carga necessária a fratura do parafuso retentor das próteses parafusadas, os componentes selecionados estão entre os mais indicados para próteses sobreimplantes parafusada, indicados também em casos de carga imediata múltipla, esta avaliação baseou-se no conhecimento do efeito da sobrecarga oclusal em uma prótese sobre implantes, que invariavelmente se traduz em perda óssea. Na ausência do ligamento periodontal a propiocepção é reduzida por tanto é necessário um sistema de segurança que desempenhe a proteção do sistema implante/prótese, função exercida por este parafuso retentor. Os conjuntos foram instalados em uma maquina EMIC DL 2000 para ensaios de compressão máxima, optou-se por uma base metálica para que não ocorresse qualquer tipo de compensação da carga. os resultados obtidos nos diferentes grupos foram, grupo 1: 508.2 Ncm, grupo2: 561.4 Ncm, grupo 3: 660.8 Ncm, grupo 4: 654.4 Ncm, concluindo-se que a força necessária para fraturar o parafuso retentor da prótese sobre componentes miruscone é 30% maior do que sobre componentes estheticone, e que mesmo com parafusos de materiais diferentes, ouro e titânio, os miruscone não apresentaram diferença significativa, logo é válido salientar que combinações de componentes como estheticone e parafuso de ouro oferecem maior segurança em função de uma necessidade menor de carga para fratura do parafuso, que apesar de parecer um ponto fraco da prótese, se traduz em um importante auxiliar no diagnóstico de uma sobrecarga oclusal. Apesar de incompatível com as forças intraorais normais, forças desta magnitude podem ser observadas em casos de parafunção ou em situações de risco biomecânico, portanto devem ser evitadas, prevenidas e acompanhadas em períodos de tempo que ainda não estão estipulados cientificamente pela literatura, ensaios laboratoriais envolvendo fadiga neste sentido poderiam no futuro contribuir para definir este protocolo de manutenção-
Descrição: dc.descriptionIn this laboratory trial, a comparison was made of the maximum force required to fracture the retainer screws of tapered components of screw-retained implant supported dentures. These were divided into four distinct groups of components, Group 1 (titanium cylinder for estheticone on estheticone analogue fixed by a gold screw), Group 2 (titanium cylinder for estheticone on estheticone analogue fixed by a titanium screw ), Group 3 (titanium cylinder for miruscone on a miruscone analogue fixed by a titanium screw), Group 4 (titanium cylinder for miruscone on a miruscone analogue fixed by a gold screw), all with a torque or pre-load of 20Ncm, inserted in a stainless steel metal base, on which the devices were placed at an inclination of 45 degrees in relation to the long axis of the force applied. The load required to fracture the retainer screw of the screwed dentures was evaluated, the selected components being among the most indicated for screw-retained implant supported dentures, also indicated in cases if immediate multiple load. This evaluation was based on knowledge of the effect of occlusal overload on an implant supported denture, which is invariably converted into bone loss. In the absence of periodontal ligament, proprioception is reduced, therefore it requires a safety system that protects the implant/denture system, a function performed by this retainer screw. The sets were installed in an EMIC DL 2000 machine for maximum compression tests. The option was to use a metal base, so that no load compensation would occur. The results obtained in the different groups were as follows: Group 1 508.2 Ncm, Group 2: 561.4 Ncm, Group 3: 660.8 Ncm, Group 4: 654.4 Ncm, and it was concluded that the force required to fracture the retainer screw of the denture supported on miruscone components was 30% greater than that on estheticone components, and that even with screws of different materials, gold and titanium, those of miruscone presented no significant difference, therefore it is valid to point out that combinations of components such as estheticone and a gold screw offer greater safety, as a result of requiring a lower load to fracture the screw, and although this appears to be a weak point of the denture, it is transformed into an important aid in diagnosing an occlusal overload. In spite of being incompatible with normal intraoral forces, forces of this magnitude can be observed in cases of parafunction, or in situations of biomechanical risk, therefore, they must be avoided, prevented and followed up in periods of time that have not yet been scientifically established in the literature. In this connection, and in the future, laboratory trials involving fatigue could contribute to defining this maintenance protocol-
Descrição: dc.description63f.-
Formato: dc.formatapplication/pdf-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightshttp://creativecommons.org/licenses/by-nc-nd/3.0/br/-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectImplante osseointegrado-
Palavras-chave: dc.subjectBiomecânica-
Palavras-chave: dc.subjectForça compressiva-
Título: dc.titleResistência à fratura dos parafusos retentores das próteses parafusadas sobre componentes cônicos-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.