Método não invasivo para medição de vazão utilizando sensores piezoelétricos

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorGama, Antonio Lopes-
Autor(es): dc.contributorMoreira, Roger Matsumoto-
Autor(es): dc.contributorLannes, Daniel Pontes-
Autor(es): dc.creatorNery, João Fabrício da Costa Gomes-
Autor(es): dc.creatorPastore, Pedro Rogerio Gonçalves-
Data de aceite: dc.date.accessioned2024-07-11T18:05:58Z-
Data de disponibilização: dc.date.available2024-07-11T18:05:58Z-
Data de envio: dc.date.issued2017-05-16-
Data de envio: dc.date.issued2017-05-16-
Data de envio: dc.date.issued2017-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/3597-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/763492-
Descrição: dc.descriptionEsse trabalho apresenta resultados de estudos realizados no Laboratório de Vibrações e Automação do Departamento de Engenharia Mecânica da Universidade Federal Fluminense, com a finalidade de desenvolver um método não intrusivo capaz de medir a vazão através de sensores piezoelétricos. Os estudos consistiram em analisar vibrações e deformações em tubulações originadas pela turbulência do escoamento de água. Os sensores piezoelétricos captam sinais de deformação do duto provenientes da turbulência gerada pelo escoamento. Os acelerômetros foram utilizados com a finalidade de obter uma relação da vazão com os resultados dos sensores piezoelétricos. Foram realizadas medições em diferentes configurações para as seções de testes da tubulação: trecho reto, lira, curva de raio curto e curva de raio longo. Em cada uma das configurações foram realizados ensaios com diferentes vazões, a partir de 0.2m3/h até 8.0m3/h. Como resultado final, são apresentadas correlações entre o desvio padrão dos sinais dos sensores piezoelétricos e a vazão volumétrica da água-
Descrição: dc.descriptionThis work presents results of studies carried out in the Vibration and Automation Laboratory of the Department of Mechanical Engineering of the Fluminense Federal University, which consisted of analyzing vibrations and deformations in pipes, caused by the turbulences generated by the flow of water, in order to develop a non-intrusive method capable of measuring flow using piezoelectric sensors. These sensors detect the deformation of the duct due to the turbulence generated by the flow. The signals from accelerometers were used for comparison with the results obtained with the piezoelectric sensors. Measurements were made in different configurations of test sections: straight tubes, lyre, short ray curve and long radius curve. In each of the configurations, tests with flow rates varying from 0.2m3 / h to 8.0m3 / h were performed. Correlations between the standard deviation of the piezoelectric signals and the volumetric flow rate of the water are presented-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectSensor piezoelétrico-
Palavras-chave: dc.subjectAcelerômetro-
Palavras-chave: dc.subjectMedidor de vazão-
Palavras-chave: dc.subjectEscoamento monofásico-
Palavras-chave: dc.subjectEngenharia mecânica-
Palavras-chave: dc.subjectMedidor de vazão-
Palavras-chave: dc.subjectSensor piezoelétrico-
Palavras-chave: dc.subjectPiezoelectric sensor-
Palavras-chave: dc.subjectAccelerometer-
Palavras-chave: dc.subjectFlow meter-
Palavras-chave: dc.subjectSingle phase flow-
Título: dc.titleMétodo não invasivo para medição de vazão utilizando sensores piezoelétricos-
Tipo de arquivo: dc.typeTrabalho de conclusão de curso-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.