Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Barboza, Eliane dos Santos Porto | - |
Autor(es): dc.contributor | http://lattes.cnpq.br/2752423047034126 | - |
Autor(es): dc.contributor | http://lattes.cnpq.br/1223974850664957 | - |
Autor(es): dc.creator | Robbs, Patricia Cristina Matos | - |
Data de aceite: dc.date.accessioned | 2024-07-11T18:02:45Z | - |
Data de disponibilização: dc.date.available | 2024-07-11T18:02:45Z | - |
Data de envio: dc.date.issued | 2020-04-01 | - |
Data de envio: dc.date.issued | 2020-04-01 | - |
Data de envio: dc.date.issued | 2017 | - |
Fonte completa do material: dc.identifier | https://app.uff.br/riuff/handle/1/13198 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/762445 | - |
Descrição: dc.description | As conexões do tipo Morse favorecem a estabildade mecânica dos abutments aos implantes devido a angulação das paredes de encaixe. Diversos trabalhos analisaram a importância da estabilidade mecânica para a manutenção das restaurações protéticas, considerando tanto a saúde periimplantar quanto a longevidade das próteses. No entanto, esta união mecânica dificulta o desacoplamento do complexo abutment-implante e induz deformações nas estruturas durante a remoção para manutenção do sistema, o que pode comprometer as reabilitações protéticas. O objetivo desse trabalho foi determinar a força de tração para remoção de componentes protéticos acoplados em implantes com conexões do tipo Morse. Vinte implantes osseointegráveis com diâmetro de 3.5mm com 13mm de comprimento, todos com conexão protética tipo Morse, e vinte abutments indexados, foram utilizados nesse estudo. Dez implantes possuíam angulação de parede interna de 240 (grupo 1) e dez 160 (grupo 2). Análise da rugosidade dos abutments antes e ao final dos ensaios mecânicos foi realizada. Dez abutments com 240 e dez com 160 , correspondentes aos implantes, foram conectados com torque de 20N.cm. Ensaios de ciclagem de carregamento com 200N.cm foram feitos com 200.000 ciclos para simular a mastigação. Para determinar a força necessária para remoção do abutment, uma força de tração foi aplicada com razão entre a carga mínima e máxima R=0,1. Durante análise dos abutment no rugosímetro, algumas imperfeições foram verificadas devido ao processo de fabricação dos componentes, sendo mais evidente nos componentes com angulação de 240 . Os testes de ciclagem não revelaram a necessidade de maior força para o desacoplamento do abutment nos implantes com angulação de parede de 160 e 240 . Maiores deformações foram verificadas nos implantes de 160 após análise final no rugosimetro. Esse trabalho conclui que as conexões tipo Morse com ângulos de paredes 240 e 160 e favorecem o desacoplamento do conjunto abutment-implante sem de distorção. | - |
Descrição: dc.description | Morse connections favor mechanical stability of implant abutments due to the angulation of the wall studs. Several studies have examined the importance of mechanical stability for the maintenance of prosthetic restorations, in terms of both health of the peri-implant tissues and longevity of the prostheses. However, this mechanical union hinders the decoupling of the abutment-implant system and causes structural deformations during removal for the maintenance of the system, potentially harming the prostheses. This study aims to determine the traction force required to remove prosthetic components coupled to implants with Morse-type connections. Twenty osseointegrated implants with 3.5-mm diameters, 13-mm lengths, and Morse-type connections, and 20 indexed abutments were used in this study. The inner wall angulation for 10 implants was 24º (Group 1) and that for the other 10 was 16º (Group 2). Analysis of abutment roughness was performed before and at the end of the mechanical tests. The abutments of both types were connected to the corresponding implants using a torque of 20 N.cm. Load cycling tests employing a torque of 200 N.cm were carried out in 200,000 cycles to simulate chewing. A traction force was applied with a ratio (R) of 0.1 between the minimum and maximum loads to determine the force required to remove the abutment. During the analysis of the abutment in a profilometer, some imperfections due to the manufacturing process of the components were identified. These were more evident in parts with 24ºangulation. Cycling tests did not establish the need for greater strength to decouple the implant abutments with wall angulations of 16º and 24º. Greater deformations were identified in the 16º-angulation implants after final analysis in the profilometer. This study concludes that Morse-type connections with wall angulations of 24º and 16º favor the decoupling of the abutment-implant system with no distortions. | - |
Descrição: dc.description | 24f. | - |
Formato: dc.format | application/pdf | - |
Idioma: dc.language | pt_BR | - |
Direitos: dc.rights | openAccess | - |
Direitos: dc.rights | openAccess | - |
Direitos: dc.rights | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ | - |
Direitos: dc.rights | CC-BY-SA | - |
Palavras-chave: dc.subject | Conexões morse | - |
Palavras-chave: dc.subject | Implantes | - |
Palavras-chave: dc.subject | Estabilidade mecânica | - |
Palavras-chave: dc.subject | Implante dentário | - |
Palavras-chave: dc.subject | Resistência a tração | - |
Palavras-chave: dc.subject | Retenção em dentadura | - |
Palavras-chave: dc.subject | Rugosidade (superfície) | - |
Palavras-chave: dc.subject | Connections morse | - |
Palavras-chave: dc.subject | Implants | - |
Palavras-chave: dc.subject | Mechanical stability | - |
Título: dc.title | Avaliação da força para desacoplamento do conjunto abutment – implante com conexão tipo morse | - |
Título: dc.title | Evaluation of strength required for decoupling the abutment-implant system with a morse-type connection | - |
Tipo de arquivo: dc.type | Dissertação | - |
Aparece nas coleções: | Repositório Institucional da Universidade Federal Fluminense - RiUFF |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: