Atenção: Todas as denúncias são sigilosas e sua identidade será preservada.
Os campos nome e e-mail são de preenchimento opcional
Metadados | Descrição | Idioma |
---|---|---|
Autor(es): dc.contributor | Helayel, Michel José Sales Abdalla | - |
Autor(es): dc.contributor | Caldas, Saulo Andrade | - |
Autor(es): dc.contributor | Silva, Paulo César Amaral Ribeiro da | - |
Autor(es): dc.contributor | Alencar, Nayro Xavier | - |
Autor(es): dc.contributor | Lessa, Daniel Augusto Barroso | - |
Autor(es): dc.contributor | http://lattes.cnpq.br/9022001218663372 | - |
Autor(es): dc.contributor | http://lattes.cnpq.br/1245586451009567 | - |
Autor(es): dc.contributor | http://lattes.cnpq.br/8157153481099643 | - |
Autor(es): dc.creator | Chenard, Maria Galindo | - |
Data de aceite: dc.date.accessioned | 2024-07-11T18:02:44Z | - |
Data de disponibilização: dc.date.available | 2024-07-11T18:02:44Z | - |
Data de envio: dc.date.issued | 2021-06-02 | - |
Data de envio: dc.date.issued | 2021-06-02 | - |
Data de envio: dc.date.issued | 2020 | - |
Fonte completa do material: dc.identifier | https://app.uff.br/riuff/handle/1/22266 | - |
Fonte completa do material: dc.identifier | http://dx.doi.org/10.22409/MPV-CV.2021.m.06241294709 | - |
Fonte: dc.identifier.uri | http://educapes.capes.gov.br/handle/capes/762442 | - |
Descrição: dc.description | Na medicina veterinária são escassas, e até mesmo ausentes, as citações sobre o uso e precisão do glicosímetro portátil em animais de produção. Neste contexto, o estudo tem como avaliar a precisão do glicosímetro portátil (GP) para dosagem da glicemia em caprinos e ovinos saudáveis em condições de normoglicêmia, hipoglicemia e hiperglicemia, foram utilizados de 60 ovinos e 60 caprinos (normoglicêmicos), 15 animais de cada espécie induzidos à hiperglicemia através de infusão intravenosa de 150 mg/kg de glicose e 15 animais de cada espécie induzidos a hipoglicemia através da administração 0,7 UI/kg de insulina ultrarrápida via subcutânea. Todos os animais foram submetidos a exame clínico e hemograma. As coletas de sangue foram realizadas através de punção da veia jugular em tubos contendo fluoreto de sódio. As mensurações da glicemia no GP e ME foram realizadas na Faculdade de Veterinária (UFF). As análises estatísticas foram realizadas no programa (SPSS) versão 8.0®. Para ovinos e caprinos os resultados não apresentaram distribuição normal para teste de Kolmogorov-Smirnov, foram feitas estatísticas descritivas, correlação de Pearson (R2) 99 e 98,5 %, teste de Levene 87 e 64,9 %. Foram avaliados extremos glicêmicos de 6 a 271 mg/dL. Em ambas as espécies foram definidos dois pontos de corte para fins de avaliação da sensibilidade 86 e 80,6 %; especificidade 95,5 e 95,7 %, valor preditivo positivo 98,5 e 98,2 %, valor preditivo negativo 84 e 62,9 %, índice Kappa 94,4 e 84,4 % e área sob a curva ROC 97,4 e 98,9 %, entre os testes GP e ME respectivamente. No teste estatístico de Bland Altman, verificou-se concordância entre os dois métodos (acurácia analítica e clínica) sendo possível, verificar que a diferença das médias se aproximou de zero nas duas espécies estudadas. Podendo-se concluir que os resultados validam o GP como método de diagnóstico para aferição da glicemia em pequenos ruminantes fornecendo resultados satisfatórios e confiáveis em comparação ao ME | - |
Descrição: dc.description | Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro - FAPERJ | - |
Descrição: dc.description | In veterinary medicine, citations about the use and accuracy of the portable glucometer in farm animals are scarce, and even absent. In this context, the study aims to evaluate the accuracy of the portable glucometer (GP) for measuring blood glucose in healthy goats and sheep under conditions of normoglycemia, hypoglycemia and hyperglycemia, 60 sheep and 60 goats (normoglycemic) were used, 15 animals of each species induced to hyperglycemia through an intravenous infusion of 150 mg / kg of glucose and 15 animals of each species induced to hypoglycemia through the administration of 0.7 IU / kg of ultra-fast insulin subcutaneously. All animals were submitted to clinical examination and complete blood count. Blood collections were performed by puncture of the jugular vein in tubes containing sodium fluoride. Blood glucose measurements in GP and ME were performed at the Faculty of Veterinary Sciences (UFF). Statistical analyzes were performed using the program (SPSS) version 8.0®. For sheep and goats, the results did not show a normal distribution for the Kolmogorov-Smirnov test, descriptive statistics were made, Pearson correlation (R2) 99 and 98.5%, Levene test 87 and 64.9%. Glycemic extremes of 6 to 271 mg / dL were evaluated. In both species, two cutoff points were defined for the purpose of assessing sensitivity 86 and 80.6%; specificity 95.5 and 95.7%, positive predictive value 98.5 and 98.2%, negative predictive value 84 and 62.9%, Kappa index 94.4 and 84.4% and area under the ROC 97 curve, 4 and 98.9%, between the GP and ME tests respectively. In the Bland Altman statistical test, agreement was found between the two methods (analytical and clinical accuracy), making it possible to verify that the difference in means was close to zero in the two species studied. It can be concluded that the results validate the GP as a diagnostic method for measuring blood glucose in small ruminants providing satisfactory and reliable results in comparison to ME | - |
Descrição: dc.description | 79 f. | - |
Formato: dc.format | application/pdf | - |
Idioma: dc.language | pt_BR | - |
Direitos: dc.rights | Open Access | - |
Direitos: dc.rights | http://creativecommons.org/licenses/by-nc-nd/3.0/br/ | - |
Direitos: dc.rights | CC-BY-SA | - |
Palavras-chave: dc.subject | Dosagem | - |
Palavras-chave: dc.subject | Sangue | - |
Palavras-chave: dc.subject | Glicose | - |
Palavras-chave: dc.subject | Caprinos | - |
Palavras-chave: dc.subject | Ovinos | - |
Palavras-chave: dc.subject | Metabolismo | - |
Palavras-chave: dc.subject | Diagnóstico veterinário | - |
Palavras-chave: dc.subject | Caprinos | - |
Palavras-chave: dc.subject | Ovinos | - |
Palavras-chave: dc.subject | Dosage | - |
Palavras-chave: dc.subject | Blood | - |
Palavras-chave: dc.subject | Glucose | - |
Palavras-chave: dc.subject | Goats | - |
Palavras-chave: dc.subject | Sheep | - |
Palavras-chave: dc.subject | Metabolism | - |
Título: dc.title | Validação do glicosímetro portátil na dosagem da glicemia de pequenos ruminantes normoglicêmicos e induzidos a hipoglicemia e hiperglicemia | - |
Tipo de arquivo: dc.type | Dissertação | - |
Aparece nas coleções: | Repositório Institucional da Universidade Federal Fluminense - RiUFF |
O Portal eduCAPES é oferecido ao usuário, condicionado à aceitação dos termos, condições e avisos contidos aqui e sem modificações. A CAPES poderá modificar o conteúdo ou formato deste site ou acabar com a sua operação ou suas ferramentas a seu critério único e sem aviso prévio. Ao acessar este portal, você, usuário pessoa física ou jurídica, se declara compreender e aceitar as condições aqui estabelecidas, da seguinte forma: