Estabilidade dimensional dos alinhadores Invisalign durante a utilização de elásticos intermaxilares: um estudo in vitro

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorVilella, Oswaldo de Vasconcellos-
Autor(es): dc.contributorMattos, Cláudia Trindade-
Autor(es): dc.contributorCamardella, Leonardo Tavares-
Autor(es): dc.contributorhttp://lattes.cnpq.br/0039989672996205-
Autor(es): dc.contributorhttp://lattes.cnpq.br/5571797125926701-
Autor(es): dc.creatorFernandes, Fabrício Sanches-
Data de aceite: dc.date.accessioned2024-07-11T18:01:44Z-
Data de disponibilização: dc.date.available2024-07-11T18:01:44Z-
Data de envio: dc.date.issued2021-05-20-
Data de envio: dc.date.issued2021-05-20-
Data de envio: dc.date.issued2019-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/22141-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/762121-
Descrição: dc.descriptionO sistema de alinhadores estéticos é uma alternativa para o tratamento ortodôntico de pacientes mais exigentes em relação à estética e ao conforto. Apesar desses sistemas utilizarem alta tecnologia na produção dos alinhadores, relatos de deformações são encontrados na literatura. Objetivo: O objetivo deste estudo foi avaliar se o uso dos elásticos intermaxilares afeta a estabilidade dimensional dos alinhadores. Método: Foram utilizados 20 pares de alinhadores novos da marca Invisalign, sendo 10 deles com encaixes para elásticos intermaxilares feitos pela própria empresa, chamados de precision cuts, e outros 10 com encaixes feitos manualmente. Foram confeccionados modelos de resina epóxi para os alinhadores, que posteriormente foram montados em um articulador. Elásticos intermaxilares foram instalados nos encaixes, com uma força de 130g. Os elásticos foram substituídos a cada 24 horas. Medições de distâncias transversais e anteroposteriores foram realizadas em pontos predeterminados antes da utilização dos elásticos e após 24 horas, sete e 14 dias desde o início da aplicação da força. Dez alinhadores foram mantidos imersos em saliva artificial a 37ºC e outros 10 foram mantidos ao ar livre, fora do meio líquido. A comparação entre os tempos e os grupos foi feita através do teste ANOVA. Resultados: Alterações estatisticamente significantes ocorreram, principalmente, nas primeiras 24 horas. Em ambiente seco, os alinhadores com precision cuts sofreram as maiores deformações. Em meio aquoso, as alterações foram agravadas em ambos os grupos. Conclusões: A instalação dos elásticos intermaxilares é capaz de produzir deformações dimensionais nos alinhadores. Quanto mais próximo do sítio de encaixe para o elástico, maiores são as alterações, que podem ser consideradas clinicamente significantes-
Descrição: dc.descriptionAesthetic aligner systems represent an alternative orthodontic treatment for patients who demand high levels of aesthetics and comfort. Although these systems use advanced technology for the production of aligners, reports of deformations can be found in the literature. Objective: The purpose of this study was to evaluate whether intermaxillary elastics influence the dimensional stability of aligners. Methods: Twenty new Invisalign pairs of aligners were tested: 10 contained inserts for intermaxillary elastics made by the company (called “precision cuts”), and 10 had inserts that were manually made by the researchers. Epoxy resin models were made for aligners, which were later mounted on an articulator. Intermaxillary elastics were installed in the fittings with a force of 130g. The elastics were replaced every 24 hours. Width and anteroposterior distance measurements were made at predetermined points before the use of elastics and 24 hours, 7and 14 days afterthe beginning of force application. Ten models with the pair of aligners were immersed in artificial saliva at 37°C during the experimental period, and the other 10 were kept in a dry environment. Comparison between time periods and between groups was performed with ANOVA. Results: Statistically significant changes were observed, mainly in the first 24 hours. In the dry environment, aligners with precision cuts suffered the greatest deformations. The changes incresead in both groups when maintained in an aqueous environment. Conclusions: The installation of intermaxillary elastics is capable of producing dimensional deformations in the aligners. The closer the fitting site for the elastic, the greater the changes. These deformations can be considered clinically significant-
Descrição: dc.description32f.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Direitos: dc.rightsOpen Access-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectAlinhadores estéticos-
Palavras-chave: dc.subjectInvisalign-
Palavras-chave: dc.subjectOrtodontia-
Palavras-chave: dc.subjectOrtodontia-
Palavras-chave: dc.subjectAparelho ortodôntico removível-
Palavras-chave: dc.subjectEstética dentária-
Palavras-chave: dc.subjectAesthetic aligners-
Palavras-chave: dc.subjectOrthodontics-
Título: dc.titleEstabilidade dimensional dos alinhadores Invisalign durante a utilização de elásticos intermaxilares: um estudo in vitro-
Tipo de arquivo: dc.typeDissertação-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.