Comparação da fiabilidade entre valores obtidos a partir de mensurações sobre radiografias cefalométricas convencionais e imagens 3D E 2D geradas a partir de TC cone beam

Registro completo de metadados
MetadadosDescriçãoIdioma
Autor(es): dc.contributorVilella, Oswaldo de Vasconcellos-
Autor(es): dc.contributorMucha, José Nelson-
Autor(es): dc.contributorMotta, Andrea Fonseca Jardim da-
Autor(es): dc.contributorAssunção, Paulo Sérgio de-
Autor(es): dc.creatorCouceiro, Carolina Perez-
Data de aceite: dc.date.accessioned2024-07-11T18:00:35Z-
Data de disponibilização: dc.date.available2024-07-11T18:00:35Z-
Data de envio: dc.date.issued2018-07-24-
Data de envio: dc.date.issued2018-07-24-
Data de envio: dc.date.issued2007-
Fonte completa do material: dc.identifierhttps://app.uff.br/riuff/handle/1/7096-
Fonte: dc.identifier.urihttp://educapes.capes.gov.br/handle/capes/761785-
Descrição: dc.descriptionOBJETIVO: Comparar a confiabilidade de pontos identificados sobre radiografias cefalométricas convencionais e sobre imagens geradas pela tomografia computadorizada cone beam, em 3D e em 2D. METODOLOGIA: O material constou de imagens obtidas através do tomógrafo computadorizado cone beam, em norma lateral, em 2D e 3D, impressas em papel fotográfico, e radiografias cefalométricas laterais, realizadas na mesma clínica radiológica e no mesmo dia, de dois pacientes pertencentes aos arquivos do Curso de Especialização em Ortodontia da Faculdade de Odontologia da Universidade Federal Fluminense. Dez alunos do Curso de Especialização em Ortodontia da Universidade Federal Fluminense identificaram pontos de referência sobre papel de acetato transparente e foram feitas mensurações das seguintes variáveis cefalométricas: ANB, FMIA, IMPA, FMA, ângulo interincisal, 1 – NA (mm) e 1 – NB (mm). Em seguida foram calculadas médias aritméticas, desvios padrão, e variância de cada medida em cada paciente. RESULTADOS E CONCLUSÃO: As imagens em 3D apresentaram maior fiabilidade quanto à identificação de certos pontos cefalométricos, como os pontos subespinhal (A), supramental (B) e násio (N). Entretanto, como essas imagens não permitem a visualização de pontos intracranianos, torna-se necessário que análises cefalométricas específicas sejam elaboradas, para que este tipo de exame possa se tornar rotineiro na clínica ortodôntica.-
Descrição: dc.descriptionOBJECTIVE: To compare the reliability of points identified on conventional cephalometric radiographs and on images 3D and 2D generated by the cone beam computed tomography. METHODOLOGY: The material consisted of 2D and 3D images obtained by cone beam computed tomography, in lateral projection, printed on photographic paper, and lateral cephalometric radiographs realized at the same radiological clinic and in the same day, of two patients belonging to archives Post-Graduation Course on Orthodontics of the Federal Fluminense University Dentistry School. Ten students of the Post-Graduation Course on Orthodontics of this University identified landmark points on transparent acetate paper and measurements were made of the following cephalometric variables: ANB, FMIA, IMPA, FMA, interincisal angle, 1 - NA (mm) and 1 - NB (mm). Then, arithmetic averages, standard deviations and variance of each measure of each patient were calculated. RESULTS AND CONCLUSIONS: The images in 3D had higher reliability concerning to the identification of certain cephalometric points, as the points A, B and N. Meanwhile, as the images in 3D do not allow the display of intracranial points, it is necessary that specific cephalometric analysis be prepared, so that this type of examination can become routine in the orthodontic clinic.-
Formato: dc.formatapplication/pdf-
Idioma: dc.languagept_BR-
Publicador: dc.publisherUniversidade Federal Fluminense-
Publicador: dc.publisherNiterói-
Direitos: dc.rightsopenAccess-
Direitos: dc.rightsCC-BY-SA-
Palavras-chave: dc.subjectTomografia computadorizada-
Palavras-chave: dc.subjectRadiografia cefalométrica lateral-
Palavras-chave: dc.subjectCefalometria-
Palavras-chave: dc.subjectRadiografias Cefalométricas-
Palavras-chave: dc.subjectTomografia Computadorizada-
Palavras-chave: dc.subjectCefalometria-
Palavras-chave: dc.subjectCone beam computed tomography-
Palavras-chave: dc.subjectLateral cephalometric radiograph-
Palavras-chave: dc.subjectCephalometrics-
Título: dc.titleComparação da fiabilidade entre valores obtidos a partir de mensurações sobre radiografias cefalométricas convencionais e imagens 3D E 2D geradas a partir de TC cone beam-
Tipo de arquivo: dc.typeTrabalho de conclusão de curso-
Aparece nas coleções:Repositório Institucional da Universidade Federal Fluminense - RiUFF

Não existem arquivos associados a este item.